Sealey D12512V User manual

INSTRUCTIONS FOR:
PORTABLE DIESEL TANK 12V
125ltr, 220ltr
PART NO’S: D12512V, D22012V
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions
and maintained properly, give you years of trouble free performance.
Refer to
Instruction Manual
Wear Protective
Gloves
1. SAFETY
WARNING: this tank must ONLY be used for diesel fuel.
Place the tank on aflat surface before filling.
Secure the tank to strong points with ratchet straps before transporting in or on a vehicle.
Maintain the pump in good condition (use an authorised service agent).
Replace or repair damaged parts. Use recommended parts only. Non authorised parts may be dangerous and will invalidate the warranty.
Keep the pump clean for best and safest performance.
Ensure the power supply (vehicle battery) corresponds with the requirements of the pump (12V dc).
Disconnect from battery when not in use.
Wear protective gloves, and protective clothing when working around fuel. A full range of personal safety equipment is available from your
local Sealey dealer.
Keep children and unauthorised persons away from the working area.
DO NOT place the tank near any heat source.
DO NOT start or stop the pump by connecting or disconnecting the battery clamps.
DO NOT allow the unit to get wet.
DO NOT operate the pump with wet hands.
DO NOT use the pump where explosive or flammable vapours may be present.
DO NOT tamper with the pump connections.
2. INTRODUCTION
Manufactured in Italy from HDPE for the safe transportation and dispensing of diesel fuel when supplying on site equipment. Complies with
ADR1.1.3.1.C for exemption from requirements of ADR regulations. Supplied with a 12V electric pump, 4mtr electric cable and clamps, security
valve and a 4mtr delivery hose with automatic fuel nozzle. Can be safely transported on a pick-up truck or van, with forklift points and 6 handles
for positioning. Model No’s D12512V & D22012V are supplied without lockable cover - order Model No. DC125 for the optional cover. Available in
sizes 125, 220ltr. Not suitable for petrol.
3. SPECIFICATION
Model No: ..............................D12512V.............................D22012V
Voltage: ................................12V .....................................12V
Current: ................................22A ..................................... 22A
Power: .................................140W ..................................140W
Tank Capacity: ...........................125ltr...................................220ltr
Flow Rate: ..............................40ltr/min ............................. 40ltr/min
Duty Cycle: .............................30mins on/30mins off .........30mins on/30mins off
Dimensions (L x W x H): ...................800 x 600 x 450mm ........... 800 x 600 x 650mm
Optional Lockable Cover: ..................DC125 ................................DC125
Key:
1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filler Cap
2 . . . . . . . . . . . . . . . . . . . . . . . . . Security Valve
3 . . . . . . . . . . . . . . . . . . . . Pump On/Off Switch
4 . . . . . . . . . . . . . . . . . . . . .Battery Clip Storage
5 . . . . . . . . Lockable Dispenser Nozzle Storage
6 . . . . . . . . . . . . . . . . .Securing Strap Locations
fig.1
D12512V, D22012V Issue: 1 - 23/09/15
Original Language Version
© Jack Sealey Limited

4.1. Filling and Transport
4.1.1. Move the empty tank assembly with two persons using the hand holds moulded into
the base of the unit (fig.2).DO NOT run the pump without fuel in the tank. To do so will
damage the pump’s internal components and will invalidate your warranty.
4.1.2. The tank is filled by unscrewing the filler (fig.1.1) in an anticlockwise direction. Refit the
filler cap immediately after filling.
WARNING take care not to overfill the tank.
4.1.3. The full tank can be moved by forklift truck using the fork locations shown in fig.2.
Ensure that both the filler (fig.1.1) and security valve (fig.1.2) are closed before moving.
4.1.4. Secure the tank to the carrying vehicle by ratchet straps. Locations for the straps are
moulded into the tank (fig1.6.).
4.2. Fuel Dispensing
4.2.1. Before connecting to a battery, make sure that the pump switch (fig.1.3) is in the ‘off’ (O) position.
Connect the battery clips to the 12V battery, observing correct polarity (red clamp to +ve terminal,
black clamp to -ve terminal)
4.2.2. Open the security valve (fig.1.2).
4.2.3. Switch the pump switch to the ‘on’ (I) position.
4.2.4. Unwind sufficient hose and place the nozzle in the receiving tank and pull the trigger (fig.3);
delivery will commence and continue until the trigger is released.
4.2.5. The trigger can be locked in one of three positions by engaging the latch (fig.3) to hold the
trigger open. DO NOT leave the nozzle unattended with the trigger latched open.
4.2.6. Slight pressure on the trigger will release the latch.
4.2.7. When the level in the receiving tank reaches the nozzle, delivery will stop automatically.
4.2.8. When delivery is complete, switch off the pump and close the security valve.
Ensure that hose is wound into its housing on the tank and that the nozzle is secured in its storage place.
4.2.9.DO NOT operate the pump continuously for more than 30 minutes. The duty cycle of the unit is
30 minutes, after which the motor must be left to cool down for a further 30 minutes.
4.2.10.DO NOT run the unit for more than 2-3 minutes with the delivery nozzle closed.
5.1. The pump contains no user-servicable parts. Repairs should only be undertaken by competent persons.
5.2. Check the integrity of all the hose connections periodically. If any leakage is evident, strip the joint and wind PTFE tape around the
male thread.
5.3. Check all electrical connections and cables for wear and damage. Rectify any faults found.
5.4. Keep clean, especially the dispenser nozzle. Clean with a damp, soapy cloth. DO NOT use abrasive or solvent cleaners.
6.1. The optional cover (part no: DC125) is fitted by inserting the hinge bolts through the holes in the cover and securing into the threaded
brass fittings in the rear top corners of the tank (fig.4).
6.2. The lock plate is fitted to the threaded fittings on the front of the tank (fig.4).
6.2. To engage the lock: adjust the clasp by turning around the threaded stem until it just clears the hook on the tongue, ensuring that the
staple is on the right. Place over the lock tongue and push the lock handle over the clasp with the staple protruding through the
slot (fig.5). If required, secure the lock handle by fitting a padlock (not supplied) through the staple.
5. MAINTENANCE
6. OPTIONAL COVER
4. OPERATION
fig.3
Environmental Protection
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
into approved containers and dispose of the product and the fluids according to local regulations.
WEEE Regulations
Dispose of this product at the end of its working life in compliance with the EU Directive on
Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed
of in an environmentally protective way. Contact your local solid waste authority for recycling information.
fig.4 fig.5
fig.2
This manual suits for next models
1
Other Sealey Tank Equipment manuals
Popular Tank Equipment manuals by other brands

Astro Pneumatic Tool
Astro Pneumatic Tool PT2-4 quick start guide

Franklin Fueling Systems
Franklin Fueling Systems EVO 600 Operation guide

TransTank
TransTank TopCrop Operator's handbook

WELBA
WELBA TW-32 quick start

Amtrol
Amtrol FILL-TROL FT-109 Installation & operation instructions

Regulus
Regulus RBC 200 Installation and operation manual