manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SECO-LARM
  6. •
  7. Lock
  8. •
  9. SECO-LARM SLI ENFORCER 1200-lb Electromagnetic Lock... User manual

SECO-LARM SLI ENFORCER 1200-lb Electromagnetic Lock... User manual

This manual suits for next models

3

Other SECO-LARM Lock manuals

SECO-LARM SD-995C-D3Q User manual

SECO-LARM

SECO-LARM SD-995C-D3Q User manual

SECO-LARM E-941SA-80Q User manual

SECO-LARM

SECO-LARM E-941SA-80Q User manual

SECO-LARM SD-991A-D1Q User manual

SECO-LARM

SECO-LARM SD-991A-D1Q User manual

SECO-LARM SD-993B-SS User manual

SECO-LARM

SECO-LARM SD-993B-SS User manual

SECO-LARM E-941SA-600 User manual

SECO-LARM

SECO-LARM E-941SA-600 User manual

SECO-LARM SLI E-941SA-600 User manual

SECO-LARM

SECO-LARM SLI E-941SA-600 User manual

SECO-LARM E-942FC-1300 User manual

SECO-LARM

SECO-LARM E-942FC-1300 User manual

SECO-LARM E-941DA-600Q User manual

SECO-LARM

SECO-LARM E-941DA-600Q User manual

SECO-LARM ENFORCER SD-961A-36 User manual

SECO-LARM

SECO-LARM ENFORCER SD-961A-36 User manual

SECO-LARM SD-997B-1SQ User manual

SECO-LARM

SECO-LARM SD-997B-1SQ User manual

SECO-LARM SD-994C User manual

SECO-LARM

SECO-LARM SD-994C User manual

SECO-LARM SD-231-ND1Q User manual

SECO-LARM

SECO-LARM SD-231-ND1Q User manual

SECO-LARM SD-997A-GBQ User manual

SECO-LARM

SECO-LARM SD-997A-GBQ User manual

SECO-LARM SD-993B-SS User manual

SECO-LARM

SECO-LARM SD-993B-SS User manual

SECO-LARM SLI E-942FC-1K3SQ User manual

SECO-LARM

SECO-LARM SLI E-942FC-1K3SQ User manual

SECO-LARM SD-996C-NUVQ User manual

SECO-LARM

SECO-LARM SD-996C-NUVQ User manual

SECO-LARM E-946FC-600Q User manual

SECO-LARM

SECO-LARM E-946FC-600Q User manual

SECO-LARM E-941S-600DPSQ Series User manual

SECO-LARM

SECO-LARM E-941S-600DPSQ Series User manual

SECO-LARM SD-997C-GCQ User manual

SECO-LARM

SECO-LARM SD-997C-GCQ User manual

SECO-LARM Enforcer E-941SA-80Q User manual

SECO-LARM

SECO-LARM Enforcer E-941SA-80Q User manual

SECO-LARM CL-210M-U3BQ User manual

SECO-LARM

SECO-LARM CL-210M-U3BQ User manual

SECO-LARM E-941SA-300RQ User manual

SECO-LARM

SECO-LARM E-941SA-300RQ User manual

SECO-LARM Enforcer E-941DA-1K2P User manual

SECO-LARM

SECO-LARM Enforcer E-941DA-1K2P User manual

SECO-LARM E-941DA-600Q User manual

SECO-LARM

SECO-LARM E-941DA-600Q User manual

Popular Lock manuals by other brands

Magic 105 manual

Magic

Magic 105 manual

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Gantner

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Dorma Studio Classic Installation instruction

Dorma

Dorma Studio Classic Installation instruction

Securam ECSL-601 quick start guide

Securam

Securam ECSL-601 quick start guide

Sudhaus 3003 operating manual

Sudhaus

Sudhaus 3003 operating manual

Safety 1st 48517 user guide

Safety 1st

Safety 1st 48517 user guide

Pado FDS-10 user manual

Pado

Pado FDS-10 user manual

Esco systeQ Series installation instructions

Esco

Esco systeQ Series installation instructions

COMPX National D8951 instruction sheet

COMPX

COMPX National D8951 instruction sheet

secureo Key Box instruction manual

secureo

secureo Key Box instruction manual

Stock Loks C8713 instruction sheet

Stock Loks

Stock Loks C8713 instruction sheet

COMPX 1T-058 Information

COMPX

COMPX 1T-058 Information

Auslock T11 user manual

Auslock

Auslock T11 user manual

Stealth SAFES ShadowVault Instructions & Troubleshooting

Stealth SAFES

Stealth SAFES ShadowVault Instructions & Troubleshooting

Knox KeySecure 5 Admin & user guide

Knox

Knox KeySecure 5 Admin & user guide

Kwikset 48334/01 Quick installation guide

Kwikset

Kwikset 48334/01 Quick installation guide

Metra Electronics Door Access Terminal Combo Technical manual

Metra Electronics

Metra Electronics Door Access Terminal Combo Technical manual

Kilitronik miniK10m operating manual

Kilitronik

Kilitronik miniK10m operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ENFORCER
®
1200-lb Electromagnetic Lock
4 SECO-LARM
®
U.S.A., Inc
Troubleshooting:
Problem
Possible cause
Solutions
Door does not
lock No power
•
Check to make sure the wires are securely
tightened to the terminal block
•Check that the power supply is connected and
operating
•Make sure the lock switch is wired correctly
Status LED is
not illuminated No power
Door locks, but
can be easily
forced open
Poor contact
between
electromagnet and
armature plate
•
Make sure the electromagnet and armature
plate are properly aligned
•Make sure the contact surfaces of the
electromagnet and armature plate are clean
and free from rust
Incorrect voltage
setting
•
Check the power leads with a meter, and make
sure 12VDC or 24VDC is present
Delay in door
releasing
A secondary diode
was installed across
the electromagnet
•
The electromagnet is fitted with a metal oxide
varistor to prevent interference, so do not install
a secondary diode
No relay output
No power •Check that the power is connected and
operating
•Make sure the lock is aligned properly
•Make sure the NO/NC/COM are wired properly
Misalignment
Delay in door
relocking Check timer
•
Make sure timer is adjusted to desired delay
time
Maintenance:
•Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-
abrasive, non-corrosive cleaner
•Apply a light coat of a silicon lubricant to prevent rust Wipe away the excess
•Check that the armature plate is securely attached to the door, yet can pivot slightly around the
armature screw
•Check that the electromagnet is securely attached to the door frame
WARRANTY ENFORCER Electromagnetic Locks are warranted against defects in material and
workmanship while used in normal service for a period of one (1) year from the date of sale to the
original customer Our obligation is limited to the repair or replacement of any defective part if the unit
is returned, transportation pre-paid, to SECO-LARM
NOTI E The information and specifications printed in this manual are current at the time of publication
However, the SECO-LARM policy is one of continual development and improvement For this reason,
SECO-LARM reserves the right to change specifications without notice SECO-LARM is also not
responsible for misprints or typographical errors
Copyright © 2010 SECO-LARM U S A , Inc All rights reserved This material may not be reproduced
or copied, in whole or in part, without the written permission of SECO-LARM
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www seco-larm com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 E-mail: sales@seco-larm com
MiE
-
941SA
-
1K2PQ
_1012
docx
PI
T
S
W2
1200-lb Electromagnetic Lock Series
Manual
How it works
When power is applied to the magnetic lock, it turns on the unit's powerful built-in
electromagnet This electromagnet is attracted to the steel armature plate which is mounted on
a door, holding the door fast against unauthorized entry When power to the magnetic lock is
turned off, the electromagnet releases the armature plate, allowing the door to open In
addition, the E-941SA-1K2PQ & E-941DA-1K2PQ have built-in LEDs to show electromagnet
status, plus a status sensor to monitor whether the door is securely closed
E
-
941SA
-
1K2PQ
Single Door
w/ Status Sensor
E-941SA-1K2PDQ Single Door
w/ Status Sensor
and Timer
E
-
941DA
-
1K2PQ
Double Door
w/ Status Sensor
Note: Products with model numbers that end with “Q” or that have a round green “Q” sticker are RoHS compliant








®
1200-lb Electromagnetic Lock
2 SECO-LARM
®
U.S.A., Inc
Specifications:
E
-
941SA
-
1K2PQ
E
-
941SA
-
1K2P
D
Q
E
-
941DA
-
1K2PQ
Door Type
Single Door
Double Door
Magnet Size
10
1
/
2
”
x1
19
/
32
”
x2
5
/
8
”
(267x40x67 mm)
21”x1
19
/
32
”x2
5
/
8
”
(534x40x67 mm)
Armature Siz
e
7
1
/
4
”
x
5
/
8
”
x2
3
/
8
”
(185x16x61 mm)
7
1
/
4
”x
5
/
8
”x2
3
/
8
” x 2
(185x16x61 mm) x 2
Status Sensor
Relay,
1A@12VDC
1
Status LED (2
-
color)
Green (locked), Red (unlocked)
1
Timer
2
n/a
0,
2 5
, 5, 9 seconds
n/a
Weight
11
-
lb (5 0kg)
22 5
-
lb (10kg)
Holding Force
1200
-
lb (545kg)
1
Power
12VDC/24VDC
Current Drain
475mA@12VDC
1
/
250mA@24VDC
1
Voltage Tolerance
±
10%
Housing
Aluminum
Temperature
14°
~
131°
F
(
-
10°
~°
55
C
)
1
On each side, for double door models
2
E-941SA-1K2PDQ only
Installation:
A.
Drill holes for the mounting plate and armature
plate (see fig 1 and 2) by doing the following:
1 Fold the mounting template along the dotted
line
2 Close the door Find a mounting location on
the door frame near the upper free-moving
corner of the door, as close to the corner of
the door frame as possible
3 Place the template against the door and
frame
4 Drill two holes in the door frame and three
holes in the door as indicated on the
template
NOTE: A filler plate or an L-bracket or Z-bracket
(optional) may be required for the electromagnet,
depending on the door frame See fig 1
B. Mount the armature plate to the door using at
least two steel washers and one rubber washer
(fig 2):
NOTE: Actual installation varies according to door style
1 Put one rubber washer between two steel
washers, and place them over the armature
screw between the armature plate and the
door This will allow the armature plate to
pivot slightly around the armature screw in
order to compensate for door misalignment
2 Tighten the sexnut bolt enough so the
armature plate can withstand the force of
someone attempting to break down the door
while the electromagnet is engaged
3 Do not tighten the armature plate against the
door The plate must be able to pivot around the
armature screw
4 Make sure the anti-spin guides are in the two
guidepin holes
. Screw the mounting plate onto the door frame or
optional bracket:
1 Screw the two short self-tapping screws in the
slotted holes of the mounting plate and adjust
the position of the mounting plate so that it and
the armature plate form a 90-degree angle
2 Once the position is correct, use the long self-
tapping screws to permanently mount the
bracket
3 Remove the two short screws
D. Drill the cable access hole
E. Mount the electromagnet on the door frame (fig 1)
1 Use the Allen wrench to screw the socket-head
mounting screws through the bottom of the
electromagnet into the mounting bracket
F. Connect the power leads (fig 3)
1 Open the electromagnet and run two power
leads from the power supply through the cable
access hole into the electromagnet
2 Connect the power leads to the terminal block
and close the electromagnet
3 Test the unit
G. Insert the tamper caps into the mounting screw
access holes
NOTE: This should be the last step, as once the tamper
caps are in place, they are difficult to remove
ENFORCER
®
1200-lb Electromagnetic Lock
SECO-LARM
®
U.S.A., Inc 3
Diagrams:
Figure 1
Figure 2
Setting the timer:
Seconds
0s
3
2 5s
5s
9s
DIP swtch
position
OFF / OFF
OFF / ON
ON / OFF
ON / ON
3
Default
Relay
Voltage
Selection
Jumpers
E-941SA-1K2PDQ
Power
Supply
Status LED
3
3
Status LED:
Indicates whether
the magnetic lock
is locked or
unlocked
Green — Locked
Red — Unlocked
Off — No power
P.S.
A
B
A:
For standard function, connect control
device(s) between the power supply and
electromagnetic lock positive terminals ( + )
B:
E-941SA-PDQ only For timer function,
connect control device(s) between the power
supply negative terminal ( - ) and the
electromagnetic lock P S terminal
NOTE: Choose either A or B—do not connect both
Timer DIP Switch
E-941SA-1K2PDQ only
Status Sensor Output
SPDT rated 1A@12VDC
Voltage Selection
24VDC
Position a jumper over
the two middle pins for
24VDC operation
Status Sensor Output:
Monitors whether the protected door
is open or closed
N C — Door is open, red LED on
N O — Door closed, green LED on
Relay — 1A@12VDC
Figure 3
Status Sensor Output:
Connect to an alarm panel or
other monitoring device
12VDC
Magnet set for 12VDC
operation as supplied
from factory
*
Note: may require more than
one filler plate