SenseAir aSENSE User manual

Installation Manual
aSENSE
Dismounting of the sensor
Pull the top part upwards
Push the front part upwards while Fold the front part forwards and
keeping the wall plate steady loose it from the hooks (#1)
3
2
5
14
1
1 Top part
2 Front part
3 Wall plate
4 Screw
5 Label with
settings inside
the top part
Mounting of the sensor
The wall plate is screwed onto the wall (A) Put the top tabs of the front part into the top
holes of the wall plate.
(B) Press the lower edge of the case onto
the wall plate to latch
If the connection cables are drawn through a conduit the conduit must be sealed.
Air of different temperature may otherwise disturb the temperature measurements.
+
~
The top part is pushed under the Terminals and jumpers on aSENSE.
locking hooks of the wall plate The darker positions are default settings.
and is secured with a screw Terminals and jumpers are located under the top part.
NOTE!
If for some reason the PCB must be removed it must be handed carefully and protected from
electrostatic discharge! Normally, removing the PCB is not required.
A
B
Screw head diameter: max 7.5 mm
Screw head height: max 2.5 mm
Electrical connections
The power supply has to be connected to and . is considered as system ground. The
same ground reference has to be used for the aSENSE VAV unit and for any connected device! Unless
different transformers are used, special precautions need to be taken.
NOTE!
The signal ground is not galvanically separated from the aSENSE VAV power supply!
NOTE!
The same ground reference has to be used for the aSENSE VAV unit and for any connected device!
If possible keep the sensor powered up after mounting. Connect the analogue output before
measuring.
Connection
Terminal
Function
Electrical Data
Remarks
Power (+)
Power ground (-)
24 VAC/DC+ (+-20%), 1W
24 VAC/DC-
See note 1
Out(1)
CO2
Out(2)
Temp
Analogue Output 1 (+)
Standard 0-2000ppm
See label for non-
standard
Analogue Output 2 (+)
Standard temperature
0-50 oC or 32-122 oF
See label for non-
standard
0-10 VDC or 0-20 mA
2-10 VDC or 0-20 mA or
See label
Same as Output 1
According to positions of Out(1)
and start point jumpers.
See note 1!
According to positions of Out(2)
and start point jumpers.
See note 1 and 2!
Note 1: The ground terminal is used as negative power supply DC input or AC phase ground
(halfwave rectifier). A single transformer may be used for the entire system.
Note 2: aSENSE can deliver a voltage or a current loop for Out(1) / Out(2). To change between
voltage and current output mode the hardware jumpers are used. There is one jumper for Out(1) and
one for Out(2), so that one output can be a voltage output and the other a current output. Both, voltage
output and current output can have start points 0 % (0-10 VDC or 0-20mA) or 20% (2-10 VDC or 4-
20mA). The same start point is used for both outputs. See the user manual.
+
~
~
+
Dimensions and holes
Dimensions of sensor in mm and (inches)
Mounting of the sensor onto the wall
Screw head diameter: max 7.5 mm
Screw head height: max 2.5 mm
Dimensions of mounting plate in mm and (inches)
120(4,72)
31(1,22)
83(3,26)
29,8(1,17)
30(1,18)
7,8(0,31)
4,2(0,16)
2(0,08)
52,5(2,07)
30(1,18)
25(0,98)
30(1,18)
SenseAir®AB (headquarter)
Stationsgatan 12 Phone: +46-(0)653 - 71 77 70
Box 96 E-mail: info@senseair.com
824 08 Delsbo
SWEDEN Web site: www.senseair.com

Other manuals for aSENSE

7

Other SenseAir Transmitter manuals

SenseAir tSENSE VAV User manual

SenseAir

SenseAir tSENSE VAV User manual

SenseAir aSENSE GH (Disp) RL User manual

SenseAir

SenseAir aSENSE GH (Disp) RL User manual

SenseAir aSENSE User manual

SenseAir

SenseAir aSENSE User manual

SenseAir aSENSE User manual

SenseAir

SenseAir aSENSE User manual

SenseAir tSense User manual

SenseAir

SenseAir tSense User manual

SenseAir aSENSE User manual

SenseAir

SenseAir aSENSE User manual

SenseAir eSENSE User manual

SenseAir

SenseAir eSENSE User manual

SenseAir aSENSE User manual

SenseAir

SenseAir aSENSE User manual

SenseAir aSENSE User manual

SenseAir

SenseAir aSENSE User manual

SenseAir aSENSE User manual

SenseAir

SenseAir aSENSE User manual

SenseAir tSENSE (Disp) T RH RL User manual

SenseAir

SenseAir tSENSE (Disp) T RH RL User manual

SenseAir eSENSE Ind User manual

SenseAir

SenseAir eSENSE Ind User manual

SenseAir tSENSE VAV Disp User manual

SenseAir

SenseAir tSENSE VAV Disp User manual

SenseAir eSENSE II User manual

SenseAir

SenseAir eSENSE II User manual

SenseAir eSENSE User manual

SenseAir

SenseAir eSENSE User manual

SenseAir aSENSE RL User manual

SenseAir

SenseAir aSENSE RL User manual

SenseAir aSENSE Ind User manual

SenseAir

SenseAir aSENSE Ind User manual

Popular Transmitter manuals by other brands

taranis Q X7 manual

taranis

taranis Q X7 manual

Sensor Electronics SEC 3100 Instruction and operation manual

Sensor Electronics

Sensor Electronics SEC 3100 Instruction and operation manual

Emerson Rosemount 644 quick start guide

Emerson

Emerson Rosemount 644 quick start guide

Jamara CCX Lipo Instruction

Jamara

Jamara CCX Lipo Instruction

LRS T9601 Setup guide

LRS

LRS T9601 Setup guide

CYP CH-1106TX & RX Operation manual

CYP

CYP CH-1106TX & RX Operation manual

ICP DAS USA WLS-T01 quick start

ICP DAS USA

ICP DAS USA WLS-T01 quick start

Emerson Rosemount 3300 Series quick start guide

Emerson

Emerson Rosemount 3300 Series quick start guide

Questtel L-1SDI-NFE-TX user manual

Questtel

Questtel L-1SDI-NFE-TX user manual

Gossen MetraWatt SINEAX V604 operating instructions

Gossen MetraWatt

Gossen MetraWatt SINEAX V604 operating instructions

Air Monitor MASS-tron II/CEM Installation, operation and maintenance manual

Air Monitor

Air Monitor MASS-tron II/CEM Installation, operation and maintenance manual

CYP PU-1H7HBTL Operation manual

CYP

CYP PU-1H7HBTL Operation manual

FMUser CZH-T200 user manual

FMUser

FMUser CZH-T200 user manual

Phonak TX-300V user manual

Phonak

Phonak TX-300V user manual

satron VG Installation and Setting-Up Instructions

satron

satron VG Installation and Setting-Up Instructions

Portos RR-5T instruction manual

Portos

Portos RR-5T instruction manual

Philips SGP6024BB/27 user manual

Philips

Philips SGP6024BB/27 user manual

BFT CLONIX RTD Installation and user manual

BFT

BFT CLONIX RTD Installation and user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.