Dismounting the wall plate
The sensor is delivered with the wall plate
mounted. The wall plate has to be
removed before the sensor is mounted
onto the wall. Unscrew the screw on the
side of the box.
Wall Mounting Instruction
1) Electrical cable entry: The box has a factory mounted cable entry bushing in
dimension PG9. Never feed more than one cable through each cable entry bushing, or
else gas might leak through!
2) Screw the wall plate onto the wall: The wall plate has holes for three screws. Drill
holes for 3,5mm screws and put dowel into them. Dowels and screws 3,5 x 25mm are
included in a plastic bag
3) Attaching the sensor box to the wall plate is done by a snap-in fitting. The wall plate
has three hooks that fit in holes in the sensor box. Fasten the screw on the side of the
box.
4) The lid can be locked with the screw at the bottom of the sensor box.
If for some reason the PCB must be removed it must be handed carefully and
protected from electrostatic discharge! Normally, removing the PCB is not
required.