SEW-Eurodrive Movidrive MDX60B User manual

Gearmotors \ Industrial Gear Units \ Drive Electronics \ Drive Automation \ Services
MOVIDRIVE
®
MDX60B / 61B
O
perating Instructions
GA360000
Edition 01/2005
11300310 / EN

SEW-EURODRIVE – Driving the world

Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
3
1 Important Notes...................................................................................................... 5
2 Safety Notes ........................................................................................................... 7
2.1 Installation and startup................................................................................... 7
2.2 Operation and servicing................................................................................. 7
3 Unit Design ............................................................................................................. 8
3.1 Unit designation, nameplates and scope of delivery...................................... 8
3.2 Unit design for size 0 ................................................................................... 15
3.3 Unit design for size 1 ................................................................................... 16
3.4 Unit design for size 2S................................................................................. 17
3.5 Unit design for size 2 ................................................................................... 18
3.6 Unit design for size 3 ................................................................................... 19
3.7 Unit design for size 4 ................................................................................... 20
3.8 Unit design for size 5 ................................................................................... 21
3.9 Unit design for size 6 ................................................................................... 22
4 Installation ............................................................................................................ 23
4.1 Installation instructions for basic unit ........................................................... 23
4.2 Removing / installing the keypad ................................................................. 28
4.3 Removing / installing the front cover............................................................ 29
4.4 UL compliant installation.............................................................................. 31
4.5 Shield clamps............................................................................................... 32
4.6 Touch guard................................................................................................. 34
4.7 Wiring diagram for basic unit........................................................................ 37
4.8 Assignment of braking resistors, chokes and filters..................................... 41
4.9 Connection of system bus (SBus 1)............................................................. 46
4.10 Connection of RS485 interface.................................................................... 47
4.11 Connection of interface converter option UWS21A (RS232)....................... 48
4.12 Connection of interface converter option USB11A....................................... 49
4.13 Option combinations for MDX61B................................................................ 50
4.14 Installing and removing option cards............................................................ 51
4.15 Connection of encoder and resolver............................................................ 53
4.16 Connection of DEH11B (HIPERFACE®) option........................................... 55
4.17 Connection of DER11B (resolver) option..................................................... 59
4.18 External encoder connection ....................................................................... 61
4.19 Connection of incremental encoder simulation............................................ 64
4.20 Master/slave connection .............................................................................. 65
4.21 Connection and terminal description of the DIO11B option......................... 66
4.22 Connection Option DFC11B......................................................................... 69
5 Startup................................................................................................................... 70
5.1 General startup instructions......................................................................... 70
5.2 Preliminary work and resources................................................................... 72
5.3 Startup using the DBG60B keypad.............................................................. 73
5.4 Startup with a PC and MOVITOOLS®.......................................................... 81
5.5 Starting the motor ........................................................................................ 82
5.6 Complete parameter list............................................................................... 85
6 Operation and Service......................................................................................... 96
6.1 Operating mode displays ............................................................................. 96
6.2 Information messages.................................................................................. 97
6.3 Functions of the DBG60B keypad................................................................ 98
6.4 Memory card.............................................................................................. 101
00
I

4
Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
6.5 Malfunction information.............................................................................. 102
6.6 Fault messages and list of faults................................................................ 103
6.7 SEW electronics service ............................................................................ 107
7 Technical Data and Dimensions....................................................................... 108
7.1 CE marking, UL approval and C-Tick......................................................... 108
7.2 General technical data............................................................................... 109
7.3 MOVIDRIVE®MDX60/61B...-5_3 (400/500 V units).................................. 111
7.4 MOVIDRIVE®MDX61B...-2_3 (230 V units).............................................. 118
7.5 MOVIDRIVE®MDX60/61B electronics data.............................................. 122
7.6 MOVIDRIVE®MDX60B dimensions.......................................................... 124
7.7 MOVIDRIVE®MDX61B dimensions.......................................................... 126
7.8 Technical data for option DEH11B, option DER11B and option BW...-T... 135
7.9 Technical data of DIO11B and DFC11B options........................................ 136
8 Index of Changes ............................................................................................... 137
8.1 Changes to the previous version................................................................ 137
9 Index.................................................................................................................... 139
P
i
f
kVA
Hz
n

Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
5
1
Important Notes
Betriebsanleitung
1 Important Notes
Safety and
warning notes
Always follow the safety and warning notes in this publication!
Designated use
MOVIDRIVE®MDX60/61B drive inverters are intended for stationary installation in
control cabinets. All instructions referring to the technical data and the permissible con-
ditions where the unit is operated must be followed.
Do not start up the unit (take it into operation in the designated fashion) until you have
established that the machine complies with the EMC Directive 89/336/EEC and that the
conformity of the end product has been determined in accordance with the Machinery
Directive 98/37/EEC (with reference to EN 60204).
Electrical hazard
Possible consequences: Severe or fatal injuries.
Hazard
Possible consequences: Severe or fatal injuries.
Hazardous situation
Possible consequences: Slight or minor injuries.
Harmful situation
Possible consequences: Damage to the unit and the environ-
ment.
Tips and useful information.
A requirement of fault-free operation and fulfillment of any rights to claim under
guarantee is that you adhere to the information in the operating instructions. Read the
operating instructions before you start operating the unit!
The operating instructions contain important information about servicing.
Therefore, keep the operating instructions close to the unit.
The MOVIDRIVE®MDX60/61B drive inverters operate AC asynchronous motors with
squirrel-cage rotors or permanent-field AC synchronous motors. These motors must be
suitable for operation with frequency inverters. Do not connect any other loads to the
drive inverters.

6
Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
1Important Notes
Operating
environment
The following applications are prohibited unless measures are expressly taken to make
them possible:
Safety functions
Disposal
Please follow the current instructions. Dispose of the following materials in accordance
with the regulations in force:
• Electronics scrap (circuit boards)
• Plastic (housing)
• Sheet metal
• Copper
etc.
• Use in potentially explosive areas.
• Use in areas exposed to harmful oils, acids, gases, vapors, dust, radiation, etc.
• Use in non-stationary applications that are subject to mechanical vibration and shock
loads in excess of the requirements in EN 50178.
MOVIDRIVE®MDX60/61B drive inverters may not perform safety functions without
higher-level safety systems.
Use higher-level safety systems to guarantee the protection of machinery and people.
For safety applications, refer to the following publications:
•Safe disconnection for MOVIDRIVE®MDX60B / 61B – Conditions
•Safe disconnection for MOVIDRIVE®MDX60B / 61B – Applications

Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
7
2
Installation and startup
Safety Notes
2 Safety Notes
2.1 Installation and startup
•Never install damaged products or take them into operation. Submit a complaint
to the shipping company immediately in the event of damage.
•Installation, startup and service work may only be performed by trained
personnel observing applicable accident prevention regulations and operating
instructions! The regulations in force (e.g. EN 60204, VBG 4, DIN-VDE
0100/0113/0160) must also be complied with.
• Follow the specific instructions during installation and startup of the motor and
the brake!
•The unit meets all requirements for reliable isolation of power and electronics
connections in accordance with EN 50178. All connected circuits must also satisfy
the requirements for reliable isolation.
• Take suitable measures (e.g. disconnecting the electronics terminal block) to
ensurethattheconnected motor does not start up automatically when the inverter
is switched on.
2.2 Operation and servicing
•Disconnect the unit from the supply system before removing the protective
cover. Dangerous voltages may still be present for up to 10 minutes after mains
disconnection.
•When the unit switch is in the ON position, dangerous voltages are present at
the output terminals as well as any connected cables and motor terminals. This
also applies even when the unit is inhibited and the motor at a standstill.
• Just because the operation LED and other display elements have gone out does
not mean that the unit has been disconnected from the supply system and is de-
energized.
• The inverter output may only be switched when the output stage is inhibited.
• Make sure that preventive measures and protection devices correspond to the
applicable regulations (e.g. EN 60204 or EN 50178).
Required preventive measures: Grounding the unit
Required protection device: Overcurrent protection devices
• The unit has IP 00 enclosure with the protective cover removed. Dangerous
voltages are present on all subassemblies except for the control electronics. The
unit must be closed during operation.
•Safety functions inside the unit or a mechanical blockage may cause the motor
to stop. The removal of the source of the malfunction or a reset can result in an
automatic restart of the drive. If, for safety reasons, this is not permissible for the
driven machine, the unit must be disconnected from the supply system before
correcting the fault. In such cases, it is also forbidden for the "Auto Reset" (P841)
to be activated.

8
Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
3Unit designation, nameplates and scope of delivery
Unit Design
3UnitDesign
3.1 Unit designation, nameplates and scope of delivery
Example: Unit designation
Example: System
nameplate
MDX60B/61B..
size 0
The system nameplate for MDX60B/61B.. size 0 is attached to the side of the unit.
MDX60 B0011 - 5 A 3 - 4 00
Version 00 = Standard
0T = Application
XX = Special unit
Quadrants 4 = 4Q (with brake chopper)
Connection type 3 = 3-phase
Radio interfer-
ence suppres-
sion on the line
side
B = Radio interference suppression B
A = Radio interference suppression A
0 = No radio interference suppression
Supply voltage 5 = 380 ... 500 VAC
2 = 200 ... 230 VAC
Recommended
motor power 0011 = 1.1 kW
Version B
Series 60 = no options can be installed
61 = options can be installed
52246AXX
Figure 1: Example: System nameplate for MDX60B/61B.. size 0

Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
9
3
Unit designation, nameplates and scope of delivery
Unit Design
Example:
Nameplate of
braking resistor
for MDX60B/61B..
The braking resistor BW090-P52B is only available for MDX60B/61B size 0.
Example: System
nameplate for
MDX61B.. sizes 1
- 6
For MDX61B.. sizes 1 - 6, the system nameplate is attached to the side of the unit.
Example:
Nameplate of
power section for
MDX61B.. sizes 1
- 6
For MDX61B.. sizes 1-6, the nameplate of the power section is located at the side of
the unit.
Example: Name-
plate of control
unit for MDX61B..
sizes 1 - 6
For MDX61B.. sizes 1-6, the nameplate of the control unit is located at the side of the
unit.
54522AXX
Figure 2: Nameplate of braking resistor for MDX60B/61B.. size 0
90
55431AXX
Figure 3: Example: System nameplate for MDX61B.. sizes 1 - 6
55432AXX
Figure 4: Nameplate of power section for MDX61B.. sizes 1 - 6
55398AXX
Figure 5: Nameplate of control unit MDX61B.. sizes 1 - 6

10
Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
3Unit designation, nameplates and scope of delivery
Unit Design
Scope of delivery
• Connector housing for all signal terminals (X10 ... X17), connected
• Connector housing for the power terminals (X1 ... X4), connected
• Pluggable memory card, connected
Size 0
• 1 set of shield clamps for power cable and signal cable, not installed. The set of
shield clamps comprises:
– 2 shield clamps for power cable (2 contact clips each)
– 1 shield clamp for signal cable (1 contact clip) for MDX60B
– 1 shield clamp for signal cable (2 contact clips) for MDX61B
– 6 contact clips
– 6 screws for attaching the contact clips
– 3 screws for attaching the contact clips to the unit
Sizes 1 -6
• 1 set of shield clamps for signal cable, not installed. The set of shield clamps
comprises:
– 1 shield clamp for signal cable (1 contact clip)
– 2 contact clips
– 2 screws for attaching the contact clips
– 1 screw for attaching the shield clamp to the unit
Size 2S
• Accessories set, not installed. The accessories set (→Following illustration)
comprises:
– 2 mounting feet [1] to be plugged into the heat sink
– 2 touch guards [2] to be fastened to terminals X4: -Uz/+Uzand X3:-R(8)/+R(9).
Once the touch guards [2] have been installed, the enclosure is IP20. Otherwise
it is IP10 (→Section "Touch guards").
54587AXX
[2]
[1]

Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
11
3
Unit designation, nameplates and scope of delivery
Unit Design
Optional scope of delivery
All sizes
• Option DBM60B: Cover installation for separate mounting of the DBG60B keypad
(e.g. in the control cabinet).
Part number 824 853 2.
The DBM60B option consists of the housing in enclosure IP65 and a 5 m extension
cable (→Following illustration). The DBG60B keypad is not part of this option and
must be ordered separately.
• Option DKG60B: 5 m extension cable for DBG60B keypad.
Part number 817 583 7.
5 m extension cables are available for mounting the keypad separately in customer
housing (→Following illustration).
54412AXX
54414AXX
+
DBM60B
DKG60B

12
Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
3Unit designation, nameplates and scope of delivery
Unit Design
Size 2S
• DMP11B mounting plate option (→Following illustration), not installed.
Part number 818 398 8.
If a MOVIDRIVE®MD_60A size 2 unit is to be replaced by MOVIDRIVE®MDX61B
size 2S, the MDX61B size 2S can be fitted on the existing mounting plate with the
DMP11B mounting panel. New retaining holes do not have to be drilled.
54588AXX
DMP11B

Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
13
3
Unit designation, nameplates and scope of delivery
Unit Design
Plug adapter for
replacing
MOVIDRIVE®A
with MOVIDRIVE®
B
Three adapters have been developed to enable rapid replacement of a MOVIDRIVE®A
unit with a MOVIDRIVE®B unit in running systems.
• DAT11B: Terminal adapter, part number 824 671 8
X10 can be rearranged directly when using MOVIDRIVE®MDF, MDV or MDS. Three
plugs have to be rewired. You can avoid such rewiring work by using the DAT11B
terminal adapter. Using this adapter will prevent incorrect connection and save time.
The terminal adapter is required for terminals X11 (analog input), X12 (SBus) and
X13 (binary inputs).
• DAE15B: Encoder adapter X15, part number 817 629 9
If a motor with encoder on X15 is in operation on an MDV or MCV, the encoder is
connected via a 9-pin plug to MOVIDRIVE®A. Since the DEH11B option for
MOVIDRIVE®MDX61B comes equipped with a 15-pin plug, you will either have to
rework the encoder cable or use the encoder adapter. The encoder adapter can be
plugged directly between the existing encoder cable with 9-pin plug and the 15-pin
plug on the DEH11B. This step makes for fail-safe and fast connection of existing
drives.
Length of DAE15B: 200 mm ±20 mm
Line cross section: 6 x 2 x 0.25 mm2(AWG23)
54589AXX
54585AXX
Terminal of the 15-pin sub D plug
(MOVIDRIVE®MDX61B, option DEH11B, X15) Core color in prefabri-
cated cable Terminal of 9-pin sub
D socket
(encoder end)
1 Yellow (YE) 1
2Red(RD)2
3 Pink (PK) 3
4 Violet (VT) 4
5 Brown (BN) 8
6 Green (GN) 9
7 Blue (BU) 10
8Gray(GY)11
9 White (WH) 15
DAT11B
DAE15B

14
Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
3Unit designation, nameplates and scope of delivery
Unit Design
• DAE14B: Encoder adapter X14, part number 817 630 2
If a synchronous encoder or an encoder simulation at X14 is in operation on a
MOVIDRIVE®MDV, MDS, MCV or MCS, connection takes place via a 9-pin plug.
Since the DEH11B and DER11B options for MOVIDRIVE®MDX61B comes
equipped with a 15-pin plug, you will either have to rework the encoder cable or use
the encoder adapter. The encoder adapter can be plugged directly between the
existing encoder cable with 9-pin plug and the 15-pin plug on the DEH11B/DER11B.
This step makes for fail-safe and fast connection of existing drives.
Length of DAE14B: 200 mm ±20 mm
Line cross section: 6 x 2 x 0.25 mm2(AWG23)
54586AXX
Terminal of the 15-pin sub D plug
(MOVIDRIVE®MDX61B, option
DEH11B/DER11B, X14)
Core color in prefabricated
cable Terminal of 9-pin sub
D socket
(encoder end)
1 Yellow (YE) 1
2Red(RD)2
3 Pink (PK) 3
4 Violet (VT) 4
5 Brown (BN) 8
6 Green (GN) 9
7 Blue (BU) 10
8Gray(GY)11
9 White (WH) 15
DAE14B

Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
15
3
Unit design for size 0
Unit Design
3.2 Unit design for size 0
MDX60/61B-5A3 (400/500 V units): 0005 ... 0014
52389AXX
Figure 6: MOVIDRIVE®MDX60/61B unit design, size 0
* View of unit underside
[1] X1: Mains connection L1 (1) / L2 (2) / L3 (3) and PE connection, separable
[2] X4: Connection for DC link connection -UZ/ +UZand PE connection, separable
[3] Power shield clamp for mains connection and connection for DC link connection
[4] X2: Motor connection U (4) / V (5) / W (6) and PE connection, separable
[5] X3: Braking resistor connection R+ (8) / R- (9) and PE connection, separable
[6] Power shield clamp for motor connection and braking resistor connection
[7] Memory card
[8] 7-segment display
[9] Xterminal: Slot for DBG60B keypad or UWS21A serial interface
[10] DIP switches S11 ... S14
[11] X12: Electronics terminal strip for system bus (SBus)
[12] X11: Electronics terminal strip for setpoint input AI1 and 10 V reference voltage
[13] X13: Electronics terminal strip for binary inputs and RS-485 interface
[14] X16: Electronics terminal strip for binary inputs and outputs
[15] X10: Electronics terminal strip for binary outputs and TF/TH input
[16] Electronics shield clamp MDX61B size 0
[17] Electronics shield clamp MDX60B size 0
[18] X17: Electronics terminal strip for safety contacts for safe stop
[19] Only with MDX61B: Encoder slot
[20] Only with MDX61B: Fieldbus slot
1
2
3
7
8
9
10
11
12
13
14
15
16
20
19
64
5
1
8
*
17

16
Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
3Unit design for size 1
Unit Design
3.3 Unit design for size 1
MDX61B-5A3 (400/500 V units): 0015 ... 0040
MDX61B-2A3 (230 V units): 0015 ... 0037
52329AXX
Figure 7: MOVIDRIVE®MDX61B unit design, size 1
[1] X1: Mains connection L1 (1) / L2 (2) / L3 (3), separable
[2] X4: Connection for DC link connection -UZ/ +UZ, separable
[3] Memory card
[4] 7-segment display
[5] Xterminal: Slot for DBG60B keypad or UWS21A serial interface
[6] DIP switches S11 ... S14
[7] X12: Electronics terminal strip for system bus (SBus)
[8] X11: Electronics terminal strip for setpoint input AI1 and 10 V reference voltage
[9] X13: Electronics terminal strip for binary inputs and RS-485 interface
[10] X16: Electronics terminal strip for binary inputs and outputs
[11] X10: Electronics terminal strip for binary outputs and TF/TH input
[12] X17: Electronics terminal strip for safety contacts for safe stop
[13]X2: Motor connection U (4) / V (5) / W (6) and PE connection, separable
[14] Electronics shield clamp and PE connection
[15]X3: Braking resistor connection R+ (8) / R- (9) and PE connection, separable
[16] Encoder slot
[17] Expansion slot
[18] Fieldbus slot
[1] [2]
[15]
[16]
[18]
[17]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
X12
X11
X13
X16
X10

Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
17
3
Unit design for size 2S
Unit Design
3.4 Unit design for size 2S
MDX61B-5A3 (400/500 V units): 0055 / 0075
54525AXX
Figure 8: MOVIDRIVE®MDX61B unit design, size 2S
[1] X1: Mains connection L1 (1) / L2 (2) / L3 (3)
[2] X4: Connection for DC link connection -UZ/ +UZand PE connection
[3] Memory card
[4] 7-segment display
[5] Xterminal: Slot for DBG60B keypad or UWS21A serial interface
[6] DIP switches S11 ... S14
[7] X12: Electronics terminal strip for system bus (SBus)
[8] X11: Electronics terminal strip for setpoint input AI1 and 10 V reference voltage
[9] X13: Electronics terminal strip for binary inputs and RS-485 interface
[10] X16: Electronics terminal strip for binary inputs and outputs
[11] X10: Electronics terminal strip for binary outputs and TF/TH input
[12] X17: Electronics terminal strip for safety contacts for safe stop
[13]X2: Motor connection U (4) / V (5) / W (6)
[14] Electronics shield clamp and PE connection
[15]X3: Braking resistor connection R+ (8) / R- (9) and PE connection
[16] Encoder slot
[17] Expansion slot
[18] Fieldbus slot
[1] [2]
[15]
[16]
[18]
[17]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]

18
Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
3Unit design for size 2
Unit Design
3.5 Unit design for size 2
MDX61B-5A3 (400/500 V units): 0110
MDX61B-2A3 (230 V units): 0055 / 0075
52330AXX
Figure 9: MOVIDRIVE®MDX61B unit design, size 2
[1] X1: Mains connection L1 (1) / L2 (2) / L3 (3)
[2] X4: Connection for DC link connection -UZ/ +UZand PE connection
[3] Memory card
[4] 7-segment display
[5] Xterminal: Slot for DBG60B keypad or UWS21A serial interface
[6] DIP switches S11 ... S14
[7] X12: Electronics terminal strip for system bus (SBus)
[8] X11: Electronics terminal strip for setpoint input AI1 and 10 V reference voltage
[9] X13: Electronics terminal strip for binary inputs and RS-485 interface
[10] X16: Electronics terminal strip for binary inputs and outputs
[11] X10: Electronics terminal strip for binary outputs and TF/TH input
[12] X17: Electronics terminal strip for safety contacts for safe stop
[13] X2: Motor connection U (4) / V (5) / W (6)
[14] Electronics shield clamp and PE connection
[15] X3: Braking resistor connection R+ (8) / R- (9) and PE connection
[16] Encoder slot
[17] Expansion slot
[18] Fieldbus slot
[1] [2]
[15]
[16]
[18]
[17]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
X12
X11
X13
X16
X10

Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
19
3
Unit design for size 3
Unit Design
3.6 Unit design for size 3
MDX61B-503 (400/500 V units): 0150 ... 0300
MDX61B-203 (230 V units): 0110 / 0150
52331AXX
Figure 10: MOVIDRIVE®MDX61B unit design, size 3
[1] PE connections
[2] X1: Mains connection L1 (1) / L2 (2) / L3 (3)
[3] X4: Connection for DC link connection -UZ/ +UZ
[4] Memory card
[5]7-segment display
[6] Xterminal: Slot for DBG60B keypad or UWS21A serial interface
[7] DIP switches S11 ... S14
[8] X12: Electronics terminal strip for system bus (SBus)
[9] X11: Electronics terminal strip for setpoint input AI1 and 10 V reference voltage
[10] X13: Electronics terminal strip for binary inputs and RS-485 interface
[11] X16: Electronics terminal strip for binary inputs and outputs
[12] X10: Electronics terminal strip for binary outputs and TF/TH input
[13] X17: Electronics terminal strip for safety contacts for safe stop
[14] Electronics shield clamp and PE connection
[15] X2: Motor connection U (4) / V (5) / W (6)
[16] X3: Braking resistor connection R+ (8) / R- (9)
[17] Encoder slot
[18] Expansion slot
[19] Fieldbus slot
[1]
[19]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
[15] [16]
[17]
[18]
[2] [3]

20
Operating Instructions – MOVIDRIVE® MDX60B/61B Drive Inverters
3Unit design for size 4
Unit Design
3.7 Unit design for size 4
MDX61B-503 (400/500 V units): 0370 / 0450
MDX61B-203 (230 V units): 0220 / 0300
52332AXX
Figure 11: MOVIDRIVE®MDX61B unit design, size 4
[1] PE connection
[2] X1: Mains connection L1 (1) / L2 (2) / L3 (3)
[3] X4: Connection for DC link connection -UZ/ +UZand PE connection
[4] Memory card
[5] 7-segment display
[6] Xterminal: Slot for DBG60B keypad or UWS21A serial interface
[7] DIP switches S11 ... S14
[8] X12: Electronics terminal strip for system bus (SBus)
[9] X11: Electronics terminal strip for setpoint input AI1 and 10 V reference voltage
[10] X13: Electronics terminal strip for binary inputs and RS-485 interface
[11] X16: Electronics terminal strip for binary inputs and outputs
[12] X10: Electronics terminal strip for binary outputs and TF/TH input
[13] X17: Electronics terminal strip for safety contacts for safe stop
[14] Electronics shield clamp
[15] PE connection
[16] X2: Motor connection U (4) / V (5) / W (6)
[17] X3: Braking resistor connection R+ (8) / R- (9) and PE connection
[18] Encoder slot
[19] Expansion slot
[20] Fieldbus slot
[1]
[20]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[15]
[14]
[16] [17]
[18]
[19]
[2] [3]
Other manuals for Movidrive MDX60B