Sharp AH-XP10UXD User manual

SPLIT TYPE
ROOM AIR CONDITIONER
OPERATION MANUAL
ENGLISH
INDOOR UNIT
(Premium models)
AH-XP10UXD
AH-XP13UXD
AH-XP10UF
AH-XP15UF
AH-XP20UF
AH-XP25UF
(Standard models)
AH-XS10UF
AH-XS15UF
AH-XS20UF
AH-XS25UF
OUTDOOR UNIT
AU-X10UXD
AU-X13UXD
AU-XP10UF
AU-XP15UF
AU-XP20UF
AU-XP25UF
AU-XS10UF
AU-XS15UF
AU-XS20UF
AU-XS25UF
“Plasmacluster"and "Device of a
cluster of grapes" are registered
trademarksor trademarksof
Sharp Corporation.
R32

EN-1
WARNING
• Do not pull or deform the power supply cord.
Pulling and misuse of the power supply cord
can result in damage to the unit and cause
electrical shock.
• Be careful not to expose your body directly to
the outlet air for a long time. It may affect your
physical conditions.
• When using the air conditioner for infants,
children, elderly, bedridden, or disabled people
make sure the room temperature is suitable for
those in the room.
• Never insert objects into the unit. Inserting
objects can result in injury due to the high
speed rotation of internal fans.
• Ground the air conditioner without fail. Do not
connect the grounding wire to gas pipe, water
pipe, lightning rod or telephone grounding
wire. Incomplete grounding may cause electric
shock.
• If anything is abnormal with the air conditioner
(ex. a burning smell), stop the operation
immediately and turn the circuit breaker OFF.
• The appliance shall be installed in accordance
with national wiring regulations. Improper
cable connection can cause the power supply
cord, plug and the electrical outlet to overheat
and cause re.
• If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similarly qualied person in order
to avoid a hazard. Use only the manufacture-
specied power cord for replacement.
• Do not splash or pour water directly on the
unit. Water can cause electrical shock or
equipment damage.
• Do not attempt to install/remove/repair the unit
by yourself. Incorrect work will cause electric
shock, water leak, re etc. Consult your dealer
or other qualied service personnel for the
installation/removal/repair of the unit.
CAUTION
• Open a window or door periodically to
ventilate the room, especially when using gas
appliances. Insufcient ventilation may cause
oxygen shortage.
• Do not operate the buttons with wet hand. It
may cause electric shock.
• For safety, turn the circuit breaker off when not
using the unit for an extended period of time.
• Check the outdoor unit mounting rack
periodically for wear and to make sure it is
rmly in place.
• Do not put anything on the outdoor unit nor
step on it. The object or the person may fall
down or drop, causing injury.
• This unit is designed for residential use. Do not
use for other applications such as in a kennel
or greenhouse to raise animals or grow plants.
• Do not place a vessel with water on the unit.
If water penetrates into the unit, electrical
insulations may deteriorate and cause electric
shock.
• Do not block the air inlets nor outlets of the
unit. It may cause insufcient performance or
troubles.
• Be sure to stop the operation and turn the
circuit breaker off before performing any
maintenance or cleaning. A fan is rotating
inside the unit and you may get injured.
• This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety. Children should be
supervised to ensure that they do not play with
the appliance.
• Make sure to connect the air conditioner
to power supply of the rated voltage and
frequency. Use of a power supply with
improper voltage and frequency can result in
equipment damage and possible re.
• Do not install the unit in a place where inam-
mable gas may leak. It may cause re.
Install the unit in a place with minimal dust,
fumes and moisture in the air.
• Arrange the drain hose to ensure smooth
drainage. Insufcient drainage may cause
wetting of the room, furniture etc.
• Make sure a leak breaker or a circuit breaker
is installed, depending on the installation
location, to avoid electrical shock.
ENGLISH Please read this manual carefully before using the product.
This manual should be kept in a safe place for handy reference.
CONTENTS
IMPORTANT SAFETY
INSTRUCTIONS
• IMPORTANT SAFETY INSTRUCTIONS............EN-1
• PART NAMES (UNIT) ........................................EN-2
• PART NAMES (REMOTE CONTROL)...............EN-3
• USING THE REMOTE CONTROL.....................EN-4
• AUXILIARY MODE.............................................EN-5
• TIPS ON SAVING ENERGY ..............................EN-5
• OPERATION CONDITION.................................EN-5
• BASIC OPERATION...........................................EN-6
• ADJUSTING THEAIR FLOW DIRECTION........EN-7
• SUPER JET OPERATION..................................EN-8
• PLASMACLUSTER OPERATION......................EN-8
• LOCK ON SENSOR OPERATION.....................EN-9
• BABY MODE OPERATION................................EN-9
• ECO MODE OPERATION................................EN-10
• BEST SLEEP OPERATION .............................EN-10
• TIMER OPERATION........................................EN-11
• SELF CLEAN OPERATION .............................EN-12
• MAINTENANCE...............................................EN-12
• LIGHTING BAR................................................EN-13
• BEFORE CALLING FOR SERVICE.................EN-14
• BEFORE CALLING FOR SERVICE
(GET THE ERROR CODE) ...................................EN-15

ENGLISH
EN-2
INDOOR UNIT
OUTDOOR UNIT
13 Inlet (Air)
14 Refrigerant Pipe and Cable
15 Drainage Hose
16 Outlet (Air)
AU-X10UXD, AU-X13UXD
AU-XP10UF, AU-XP15UF, AU-XS10UF, AU-XS15UF
AU-XP20UF, AU-XS20UF AU-XP25UF, AU-XS25UF
13
14
15
16
13
14
15
16
10
11
Standard models Premium models
1
2
3
4
5
6
7
8
9
10
11
12
1 Inlet (Air)
2 Open Panel
3 Air Filter
4 AUX Button
5 Receiver Window
6 Vertical Airow Louver
7 Horizontal Airow Louver
8 Outlet (Air)
9 Lighting bar
(For XP10/13UXD,
XP10/15UF models only)
10 OPERATION Lamp
(green )
11 TIMER Lamp (orange )
12 PLASMACLUSTER Lamp
(blue )
(For Premium models only)
13
14
15
16
PART NAMES (UNIT)

EN-3
REMOTE CONTROL
1 TRANSMITTER
2 DISPLAY
3 LED Button
4 SUPER JET Button
5 ON/OFF Button
6 PLASMACLUSTER Button
7
LOCK ON SENSOR Button
8 BABY MODE Button
9 FAN Button
10 THERMOSTAT Button
11 MODE Button
12 SWING Button
(: Vertical direction)
13 ECO Button
14 TIMER ON Button
15 BEST SLEEP Button
16 TIMER OFF Button
17 RESET Button
18 TIMER CANCEL Button
19 SWING Button
( : Horizontal direction)
20 SELF CLEAN Button
1
2
5
4
8
9
10
11
15
14
13
12
18
17
16
XS10/15/20/25UF models
Standard models
1
2
4
5
7
8
6
10
9
11
12
13
14
16
15
17
18
19
20
SENSOR
XP20/25UF models
SENSOR
1
2
4
3
5
7
8
6
10
9
11
12
13
14
16
15
17
18
19
20
XP10/13UXD models
XP10/15UF models
Premium models
PART NAMES (REMOTE CONTROL)

ENGLISH
EN-4
LOADING BATTERIES
1Remove the battery cover.
2Insert two batteries. (AAA(R03))
Make sure the (+) and (-) polarities are
correctly aligned.
3Reinstall the battery cover.
4Press the RESET button using a
thin stick.
NOTE:
•
The battery life is approximately 1 year in
normal use.
•
Replace the batteries when the remote control
displays “ ”.
• When replacing the batteries, always change
both and use the same type.
• If you will not be using the unit for a long time,
remove the batteries from the remote control.
DISPLAY
USING THE REMOTE CONTROL
HOW TO USE THE REMOTE CONTROL
Point the remote control towards the
receiver window and press the desired
button. The unit generates a beep when
it receives the signal.
• Make sure nothing, such as curtains, block the
signal receiver window.
• The signal effective distance is 7 m.
CAUTION:
• Do not expose the receiver window to direct
sunlight. This may adversely affect its operation.
• Use of certain uorescent lamp in the same
room may interfere with transmission of the
signal.
• Do not leave the remote control in direct
sunlight or near a heater. Protect the remote
control from moisture and shock.
Battery cover
RESET button
1 SUPER JET Symbol
2
MODE Symbols
FAN / AUTO / COOL / DRY
3
BABY MODE Symbol
4
PLASMACLUSTER Symbol
(For Premium models only)
5 SELF CLEAN Symbol
(For Premium models only)
6 ECO Symbols
7 VERTICALAIR FLOW Symbol
8 BATTERY Symbol
9 BEST SLEEP Symbol
10 TIMER ON / TIMER OFF Indicator
11 TEMPERATURE Indicator
12 TRANSMITTING Symbol
13 FAN SPEED Symbols
: AUTO
: Manual setting
21
6
5
4
3
10
9
8
7
11
13
12
7 m
Receiver
window

EN-5
Use this mode when the remote control
is not available.
TO TURN ON
Press the AUX button.
• The green OPERATION lamp ( ) will light
up and the unit will start operating in the
AUTO mode.
• The fan speed and temperature setting are
set to AUTO.
TO TURN OFF
Press the AUX button again.
• The green OPERATION lamp ( ) will turn
off.
AUXILIARY MODE
TIPS ON SAVING ENERGY
Below are some simple ways to save
energy when you use your air conditioner.
Set the proper temperature
• Setting the temperature lower than necessary
during cooling operation will result in
increased power consumption.
Block direct sunlight and prevent drafts
•
Blocking direct sunlight during cooling operation
will reduce power consumption.
• Close the windows and doors during cooling
and heating operations.
Keep lter clean to ensure the most
efcient operation
Disconnect the power cord when the
unit is not used for an extended period
time
• The indoor unit still consumes a small amount
of power when it is not operating.
Mode Indoor
Temp. Outdoor
Temp.
Cooling Upper limit 32°C 43°C
Lower limit 21°C 21°C
• The build-in safety device may prevent
the
unit from operating when used out of
this
range.
• Condensation may form on the air outlet
if the
unit operates continuously in the COOL or
DRY mode when humidity is over 80%.
OPERATION CONDITION
AUX

ENGLISH
EN-6
1
Press the MODE button to select the
operation mode.
2
Press the ON/OFF button to start oper-
ation.
•
The green OPERATION lamp
( )
will light up.
• The lighting bar will light up to different colors.
For more information, refer to page EN-13.
(For XP10/13UXD, XP10/15UF models only)
TO TURN OFF
Press the ON/OFF button again.
•
The green OPERATION lamp
( )
will turn off.
• The lighting bar will turn off.
(For XP10/13UXD, XP10/15UF models only)
3
Press the THERMOSTAT button to set the
desired temperature, you can set temper-
ature in 0.5 °C increments.
(AUTO/DRY mode)
The temperature can be
changed up to ±2.0°C from
the automatic setting.
(COOL mode)
The temperature setting
range: 14.0-30.0°C.
4
Press the FAN button to set the desired
fan speed.
In FAN mode, fan speed cannot be set to AUTO.
BASIC OPERATION
NOTE:
AUTO MODE
In the AUTO mode, the temperature setting and
mode are automatically selected according to the
room temperature when the unit is turned on.
DRY MODE
The fan speed is preset to AUTO and cannot be changed.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store
setting when a power failure occurs.
After power recovery, the unit will automatically re-
start in the same settings which were active before
the power failure, except for TIMER, SUPER JET,
BEST SLEEP, BABY MODE, ECO MODE, SELF
CLEAN settings.
1
4
3
2
SENSOR
AUTO BREEZE QUIET SOFT LOW HIGH
BREEZE QUIET SOFT LOW HIGH
FAN AUTO COOL DRY

EN-7
HORIZONTAL AIR FLOW DIRECTION
(For Premium models)
1
Press the SWING button ( ).
• The horizontal airow louver will swing.
• The lighting bar will wave to show the
swing direction.
For more information, refer to page EN-13.
(For XP10/13UXD, XP10/15UF models only)
2
Press the SWING button ( ) again
to stop at the desired position.
CAUTION:
Never attempt to adjust the louvers manually.
• Manual adjustment of the louvers can cause
the unit to malfunction.
• When the vertical adjustment louver is
positioned at the lowest position in the COOL
or DRY mode for an extended period of time,
condensation may result.
NOTE:
• The adjustment range is narrower than the
swing range in order to prevent condensation
from dripping.
(For Standard models)
Hold the horizontal airow louver lever
and adjust the airow direction.
VERTICAL AIR FLOW DIRECTION
1
Press the SWING button ( ) to set
the desired airow direction.
In AUTO mode, airow direction cannot be
set to “ ”.
ADJUSTING THE AIR FLOW DIRECTION
1
SENSOR
1
2
SENSOR
Louver lever

ENGLISH
EN-8
SUPER JET OPERATION
The air conditioner works at the maximum
power and optimum louver direction to
make the room cool rapidly.
1
During operation, press the SUPER
JET button.
• The remote control will display “ ”.
• The temperature display will go off.
• The vertical airow louver will be set
obliquely downward.
• The lighting bar will turn to blue.
(For XP10/13UXD, XP10/15UF models only)
TO CANCEL
Press the SUPER JET button again.
• The vertical airow louver will return to the
original direction.
NOTE:
• The air conditioner will operate at “Extra
cooling power” and “Extra HIGH” fan speed
for 15 minutes, then shift to “HIGH” fan speed.
• You can not set the temperature or fan speed
during the SUPER JET operation.
NOTE:
• Use of the PLASMACLUSTER operation will
be memorized, and it will be activated the next
time you turn on the unit.
• To perform PLASMACLUSTER operation in
FAN only mode, press the PLASMACLUS-
TER button when the unit is not operating.
The lighting bar will turn to cool white(For
XP10/13UXD, XP10/15UF models only).
The mode symbol of the remote control will
go off and the fan speed cannot be set to
AUTO.
(For Premium models only)
Plasmacluster ions released into the room
will reduce some airborne mold.
1
During operation, press the PLAS-
MACLUSTER button.
• The remote control will display “ ”.
• The blue PLASMACLUSTER lamp ( )
will light up.
TO CANCEL
Press the PLASMACLUSTER button again.
• The blue PLASMACLUSTER lamp ( )
will turn off.
1
SENSOR
PLASMACLUSTER OPERATION
1
SENSOR

EN-9
Soft , quiet and clean operation cools a
room with well optimized for infants.
1During operation, press the BABY
MODE button.
• The remote control will display “ ”.
• Fan speed will be automatically set to
LOW, SOFT or QUIET.
• Louver will be set to top position (Coanda
position).
• PLASMACLUSTER will be turned on.
(For Premium models only)
• The lighting bar will turn to pink.
(For XP10/13UXD, XP10/15UF models only)
TO CANCEL
Press the BABY MODE button again.
NOTE:
• BABY MODE operation is not available in
DRY and FAN mode.
BABY MODE OPERATION
1
SENSOR
The air conditioner will cool the position of
user
more effectively in this mode.
1During operation, press the LOCK
ON SENSOR button.
• The sensor will nd the position of remote
control.
• The horizontal airow louver angle will be
automatically set toward the position of
remote control.
• The vertical airow louver angle will be set
obliquely downward.
LOCK ON SENSOR OPERATION
1
SENSOR
(For Premium models only)
NOTE:
• Make sure the remote control is pointed straight
towards the unit’s signal receiver window when
you press the LOCK ON SENSOR button, other-
wise the horizontal airow louver may not work
properly.
• The unit remembers the airow direction by
LOCK ON SENSOR button even after turned off.
• The airow direction can also be changed with
SWING button ( ) ( ). (Refer to EN-7)
• If use the LOCK ON SENSOR button when
remote control is very close to the unit, the hori-
zontal airow louver may get to center position.
• When the distance between the unit and remote
control is longer than 5 m, the unit may not detect
the position of remote control correctly.

ENGLISH
EN-10
The air conditioner will operate with
lower power consumption than usual in
this mode.
1
During operation, press the ECO
MODE button to enter 1st step pow-
er consumption mode.
• The remote control will display “ ”.
• The lighting bar will turn to green.
(For XP10/13UXD, XP10/15UF models only)
2
Press the ECO MODE button again
to enter 2nd step power consump-
tion mode.
• The remote control will display “ ”.
TO CANCEL
Press the ECO MODE button again during
2nd step power consumption mode.
ECO MODE OPERATION
1
SENSOR
2
For more comfortable sleep, temperature
and fan speed will be controlled automati-
cally by the best program.
1During operation, press the BEST
SLEEP button.
• The remote control will display “”.
• Temperature and fan speed will be con-
trolled automatically for the best sleep.
• The lighting bar will turn to orange. After
1h, the light will turn off. For more informa-
tion, refer to EN13.
(For XP10/13UXD, XP10/15UF models only)
TO CANCEL
Press the BEST SLEEP button again.
BEST SLEEP OPERATION
SENSOR
1
NOTE:
• BEST SLEEP operation is not available in
DRY and FAN mode.

EN-11
TIMER ON
1
Press the TIMER ON button and set
the time as desired.
• The orange TIMER lamp ( ) will light up.
• The timer setting will count down to show
the remaining time.
TO CANCEL
Press the CANCEL button.
• The orange TIMER lamp ( ) will turn off.
TIMER OFF
1
Press the TIMER OFF button and set
the time as desired.
• The orange TIMER lamp ( ) will light up.
• The timer setting will count down to show
the remaining time.
TO CANCEL
Press the CANCEL button.
• The orange TIMER lamp ( ) will turn off.
NOTE:
• Timer duration can be set from a minimum half an hour to a maximum of 12 hours. Up to 9.5 hours,
you can set in half-hour increments, and from 10 to 12 hours, in 1-hour increments.
• The TIMER OFF and TIMER ON can not be set together.
• When the temperature is set during timer setting, the temperature will show in the display for 5 sec-
onds and then return to the timer display.
• If a power failure occurs while the TIMER is set, the TIMER setting will be cancelled and will not be
retrieved even after the power is restored.
TIMER ON
• The unit will turn on prior to the set time to allow the room to reach the desired temperature by the
programmed time. (Awaking function)
TIMER OPERATION
CANCEL
1
SENSOR
SENSOR
SENSOR
SENSOR
1
CANCEL

ENGLISH
EN-12
Be sure to disconnect the power cord from
the wall outlet or turn off the circuit breaker
before performing any maintenance.
CLEANING THE FILTERS
1
Turn off the unit.
2
Remove the lters.
Lift the open panel.
Pull the air lters down to remove them.
3
Clean the lters.
• Use a vacuum cleaner to remove dust. If the
lters are dirty, wash them with warm water
and a mild detergent. Dry lters in the shade
before reinstalling.
4
Reinstall the lters and close the
open panel.
MAINTENANCE
MAINTENANCE AFTER AIR CONDI-
TIONER SEASON
1
Dry the inside of the indoor unit thor-
oughly by taking the following steps.
(For Premium models)
Run the unit in the SELF CLEAN operation mode.
(For Standard models)
Run the unit in the COOL mode with temperature
setting of 30°C.
2
Stop the operation and unplug the
unit.
•Turn off the circuit breaker, if you have one
exclusively for the air conditioner.
3
Clean the lters, then reinstall them.
MAINTENANCE BEFORE AIR CONDI-
TIONER SEASON
1
Make sure that the air lters are not
dirty.
2
Make sure that nothing obstructs
the air inlet or outlet.
CLEANING THE UNIT AND THE RE-
MOTE CONTROL
• Wipe them with a soft cloth.
• Do not directly splash or pour water on them. It
can cause electrical shock or equipment damage.
• Do not use hot water, thinner, abrasive powders
or strong solvents.
SELF CLEAN operation will reduce
the growth of mold fungus with
Plasmacluster ions and dry inside of the
unit. Utilize the operation at seasonal
change over terms or every 4 months.
1
Press the SELF CLEAN button when
the unit is not operating.
• The remote control will display “ ”.
• The blue PLASMACLUSTER lamp ( )
will light up.
• The lighting bar will turn to cool white.
(For XP10/13UXD, XP10/15UF models only)
• The unit will stop operation after 90 minutes.
TO CANCEL
Press the SELF CLEAN button again.
• The blue PLASMACLUSTER lamp ( )
will turn off.
SELF CLEAN OPERATION
(For Premium models only)
1
SENSOR

EN-13
LIGHTING BAR
The lighting bar on the unit turns to
different colors to show the operation
situation.
OPERATION COLOR
COOL MODE • Color: Blue or Green
•
When the room temperature
is colse to the setting
temperature, it turns to green,
otherwise it's blue.
DRY MODE
AUTO MODE
FAN MODE • Color: Cool White
SUPER JET • Color: Blue
• When Super Jet function
is started, 5 lights blink 3
times.
PLASMACLUSTER
• Color: Cool White
• Only in FAN only mode.
BABY MODE • Color: Pink
ECO MODE • Color: Green
BEST SLEEP
• Color: Orange
• All of the 5 lights will turn on
in the rst 10 seconds.
After 10 seconds, just the 1
lights in the middle will keep
lighting.
After 20 minutes all the
lights will turn off.
SELF CLEAN • Color: Cool White
LED • Color: White
• Only after press the LED but-
ton when unit is not operating.
The lighting bar also can show the
horizontal airow direction in each
mode.
• Swing:
• Center:
• Right:
• Left:
NOTE:
• When the horizontal airow direction is swing-
ing, all of the 5 lights will turn on.
After the position is decided, the lighting bar
will wave to show the direction.
If you think the lighting bar is too bright.
1
Press the LED button and the light-
ing bar will just keep the middle
light in low bright.
2
Press the LED button again and all
the lights will turn off.
TO CANCEL
Press the LED button again.
If you need some light when the unit is
not operating.
1
Press the LED button and the light-
ing bar will turn on.
TO CANCEL
Press the LED button again.
(For XP10/13UXD, XP10/15UF models only)
1
2
SENSOR
1
2
1
SENSOR

ENGLISH
EN-14
Check the following points before call-
ing for service.
The unit does not operate
• Check if the circuit breaker has tripped or the
fuse has blown.
The unit does not cool effectively
• Check the lters. If dirty, clean them.
• Check the outdoor unit to make sure nothing
is blocking the air inlet or outlet.
• Check the thermostat is proper setting.
• Make sure windows and doors are closed
tightly.
The unit does not receive the remote
control signal
• Check whether the remote control batteries
have become old and weak.
• Try to send the signal again with the remote
control pointed properly towards the unit’s
signal receiver window.
• Check whether the remote control batteries
are installed properly.
Please call for service when the green
OPERATION lamp, the orange TIMER
lamp and the blue PLASMACLUSTER
lamp on the unit blink.
To describe the malfunction to service,
you may nd out the error code by the
remote control before calling for ser-
vice.
BEFORE CALLING FOR SERVICE
The following conditions do not denote
equipment malfunctions.
UNIT DOES NOT OPERATE
The unit will not operate if it is turned on im-
mediately after it is turned off. The unit will not
operate immediately after the mode is changed.
This is to protect the unit. Wait 3 minutes before
operating the unit.
ODORS
Carpet and furniture odors that entered into the
unit may be sent out from the unit.
CRACKING NOISE
This sound is generated by the friction of the
unit expanding or contracting due to a tempera-
ture change.
MIST SEEN AT INDOOR AIR OUTLET
In cooling operation, this is caused by the differ-
ence between the room air temperature and the
air discharged.
THE OUTDOOR UNIT DOES NOT STOP
After stopping the operation, the outdoor unit
will rotate its fan for about a minute to cool
down the unit.
SWISHING NOISE
The soft, swishing noise is the sound of the
refrigerant owing inside the unit.
(For Premium models only)
ODOR EMITTED FROM THE
PLASMACLUSTER AIR OUTLET
This is the smell of ozone generated from
the Plasmacluster Ion generator. The ozone
concentration is very small, posing no adverse
effect on your health. The ozone discharged
into the air rapidly decomposes, and its density
in the room will not increase.
A LOW BUZZING NOISE
This is a sound of the unit generating Plasma-
cluster ions.
BEFORE CALLING FOR SERVICE

EN-15
3Press the FAN button once, the remote
control will display “ ”.
4
Press the THERMOSTAT button “ ”
and “ ”, remote control display
will change from “ ” to “ ” step by
step. Meanwhile, buzzer makes a short
beep sound on every step.
• When it displays “ ”, the buzzer will
make a long beep sound to remind you
this error code “ ” is sub error code.
ABOUT ERROR CODE
• The error code contains main code and sub
code.
Example: error 23-4.
ERROR CODE
Main
Code Sub
Code
GET THE ERROR CODE
Example: error 23-4.
1
Press the THERMOSTAT button “ ”
for over 5 seconds on remote control
when the indoor unit and remote control
is off.
• The remote control will display “ ” and
there will be a beep sound from the unit’s
buzzer.
2
Press the THERMOSTAT button “ ”
and “ ”, remote control display
will change from “ ” to “ ” step by
step. Meanwhile, buzzer makes a short
beep sound on every step.
• When it displays “ ”, the buzzer will
make a long beep sound to remind you
this error code “ ” is main error code.
SENSOR
14
SENSOR
2
SENSOR
3
SENSOR
BEFORE CALLING FOR SERVICE (GET THE ERROR CODE)

Printed in Thailand
TINSEA987JBRZ 16K- TH 1
This manual suits for next models
19
Table of contents
Other Sharp Air Conditioner manuals

Sharp
Sharp AE-A189J User manual

Sharp
Sharp AH-AP18KSY User manual

Sharp
Sharp AF-Q100RX User manual

Sharp
Sharp AH-X075E User manual

Sharp
Sharp AH-X08CR User manual

Sharp
Sharp AY-XPC9RR User manual

Sharp
Sharp Plasmacluster AE-X12JJ User manual

Sharp
Sharp AF-W18CME User manual

Sharp
Sharp AH-XP18UHD User manual

Sharp
Sharp AF-05CML User manual

Sharp
Sharp AY-XP07ER User manual

Sharp
Sharp AF-Q100PX User manual

Sharp
Sharp AE-X9USR User manual

Sharp
Sharp AH-A09BF User manual

Sharp
Sharp GS-XP9FGR User manual

Sharp
Sharp AE-X3M18JR User manual

Sharp
Sharp AY-XP18GR User manual

Sharp
Sharp AH-S22AW2 User manual

Sharp
Sharp AY-XPM7PHR Installation manual

Sharp
Sharp AE-X4M30PU User manual