manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Shure
  6. •
  7. Antenna
  8. •
  9. Shure PSM PA821SWB User manual

Shure PSM PA821SWB User manual

Other Shure Antenna manuals

Shure AXIENT AXT630 User manual

Shure

Shure AXIENT AXT630 User manual

Shure PSM PA760 User manual

Shure

Shure PSM PA760 User manual

Shure UA870 User manual

Shure

Shure UA870 User manual

Shure PA760 User manual

Shure

Shure PA760 User manual

Shure UA870 User manual

Shure

Shure UA870 User manual

Shure UA860SWB User manual

Shure

Shure UA860SWB User manual

Shure UA844+Z18 User manual

Shure

Shure UA844+Z18 User manual

Shure UA845 User manual

Shure

Shure UA845 User manual

Shure PA411 User manual

Shure

Shure PA411 User manual

Shure ua874V User manual

Shure

Shure ua874V User manual

Shure PA705 User manual

Shure

Shure PA705 User manual

Shure UA860WB User manual

Shure

Shure UA860WB User manual

Shure UA874 User manual

Shure

Shure UA874 User manual

Shure PA421A User manual

Shure

Shure PA421A User manual

Shure UA845 User manual

Shure

Shure UA845 User manual

Shure PA805 Series User manual

Shure

Shure PA805 Series User manual

Shure UA874 User manual

Shure

Shure UA874 User manual

Shure UA860V User manual

Shure

Shure UA860V User manual

Shure UA844SWB User manual

Shure

Shure UA844SWB User manual

Shure UA844SWB User manual

Shure

Shure UA844SWB User manual

Shure PA760 User manual

Shure

Shure PA760 User manual

Shure WA380 User manual

Shure

Shure WA380 User manual

Shure UA874 User manual

Shure

Shure UA874 User manual

Shure PA411 User manual

Shure

Shure PA411 User manual

Popular Antenna manuals by other brands

Alfa Network APA-L01 Specifications

Alfa Network

Alfa Network APA-L01 Specifications

Naval PR-422CA Operation manual

Naval

Naval PR-422CA Operation manual

Feig Electronic ID ISC.ANTH200/200 Series manual

Feig Electronic

Feig Electronic ID ISC.ANTH200/200 Series manual

TERK Technologies TV44 owner's manual

TERK Technologies

TERK Technologies TV44 owner's manual

Directive Systems & Engineering DSE2324LYRMK quick start guide

Directive Systems & Engineering

Directive Systems & Engineering DSE2324LYRMK quick start guide

HP J8999A instructions

HP

HP J8999A instructions

MobilSat MSP-S Mounting instructions

MobilSat

MobilSat MSP-S Mounting instructions

Steren ANT-UHF 13 instruction manual

Steren

Steren ANT-UHF 13 instruction manual

Novatel 600-G User information

Novatel

Novatel 600-G User information

Radio Shack Amplified VHF/UHF/FM Indoor Antenna owner's manual

Radio Shack

Radio Shack Amplified VHF/UHF/FM Indoor Antenna owner's manual

TRENDnet TEW-AO12O Specifications

TRENDnet

TRENDnet TEW-AO12O Specifications

Radio Shack 15-1837 owner's manual

Radio Shack

Radio Shack 15-1837 owner's manual

CommScope CMAX-OMFX-43M-I53 Installation instruction

CommScope

CommScope CMAX-OMFX-43M-I53 Installation instruction

Ramsey Electronics DAP25 Kit assembly and instruction manual

Ramsey Electronics

Ramsey Electronics DAP25 Kit assembly and instruction manual

COBHAM SAILOR 800 VSAT Replacement procedure

COBHAM

COBHAM SAILOR 800 VSAT Replacement procedure

Trango Systems AD900-9 Specification sheet

Trango Systems

Trango Systems AD900-9 Specification sheet

Steren ANT-100 user manual

Steren

Steren ANT-100 user manual

IWCS iriBelt II Quick start user guide

IWCS

IWCS iriBelt II Quick start user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Model PA821SWB
User Guide
©2008 Shure Incorporated
27A12135 (Rev. 1) Printed in U.S.A.
PSM®Antenna Combiner User Guide
Guide de l'utilisateur du répartiteur d'antenne PSM
Bedienungsanleitung für die Antennenweiche PSM
Guía del usuario del combinador de antenas PSM
Guida d'uso del combinatore di antenne PSM
PA821SWB
PSM Antenna Combiner
470-952Mh
z
MAINOUT
INPUT SIGNAL
ACTIVE COMBINER
1
23456
78
50O
HMS
AIN
BIN
EXPANSIONP
ORT
A+BO
UT
POWER
2
ENGLISH
DESCRIPTION
The Shure PA821 Antenna Combiners actively combine antenna out-
puts from up to eight PSM wireless transmitters to a single antenna, im-
proving RF performance and reducing rack clutter.
INSTALLATION
Set the power switch on the front panel to OFF before installing. Connect
the unit to an AC power source using the supplied power cable. Switch the
power ON to use the device. The power light will illuminate. Power the unit
OFF when not in use or before disconnecting the unit from the AC power
source.
8-TO-1 COMBINING:
1. Using the supplied BNC-BNC cables, connect the ANTENNA
OUTPUT of each transmitter to the ANTENNA INPUTS of the PA821
(Figure 2).
2. Attach an antenna to the MAIN OUT of PA821. For wideband appli-
cations, use PA805SWB directional antenna (Figure 1).
3. Connect the PA821 to a power outlet using one of the supplied power
cables. The PA821 contains a universal power supply to operate
anywhere in the world.
NOTE: When the PA821 is powered on, the input signal
indicators (1-8) on the front panel will illuminate if an active
transmitter is connected to the corresponding input (1-8) on the
back panel (Figure 1).
FIGURE 1
FIGURE 2
! IMPORTANT SAFETY INSTRUCTIONS !
1. READ these instructions.
2. KEEP these instructions.
3. HEED all warnings.
4. FOLLOW all instructions.
5. DO NOT use this apparatus near water.
6. CLEAN ONLY with dry cloth.
7. DO NOT block any ventilation openings. Install in accordance with the manu-
facturer's instructions.
8. DO NOT install near any heat sources such as radiators, heat registers, stoves,
or other apparatus (including amplifiers) that produce heat.
9. DO NOT defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wider blade or the third
prong are provided for your safety. If the provided plug does not fit into your out-
let, consult an electrician for replacement of the obsolete outlet.
10. PROTECT the power cord from being walked on or pinched, particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11. ONLY USE attachments/accessories specified by the manufacturer.
12.
13. UNPLUG this apparatus during lightning storms or when unused for long periods of
time.
14. REFER all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is dam-
aged, liquid has been spilled or objects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not operate normally, or has been
dropped.
15. DO NOT expose the apparatus to dripping and splashing. DO NOT put objects filled
with liquids, such as vases, on the apparatus.
16. The MAINS plug or an appliance coupler shall remain readily operable.
17. The airborne noise of the apparatus does not exceed 70dB (A).
18. Apparatus with CLASS I construction shall be connected to a MAINS socket outlet
with a protective earthing connection.
19. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or
moisture.
20. Do not attempt to modify this product. Doing so could result in personal injury
and/or product failure.
USE only with a cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the
apparatus. When a cart is used, use caution when
moving the cart/apparatus combination to avoid
injury from tip-over.
This symbol indicates that dangerous voltage constituting a
risk of electric shock is present within this unit.
This symbol indicates that there are important operating and
maintenance instructions in the literature accompanying this unit.
WARNING:
Voltages in this equipment are hazardous to life. No user-serviceable parts inside. Refer all servicing to qualified service personnel. The
safety certifications do not apply when the operating voltage is changed from the factory setting.
PSM Transmitters
AC
POWER
3
ENGLISH
FOR MORE THAN 8 TRANSMITTERS:
1. Using the supplied BNC-BNC cables, connect the ANTENNA
OUTPUT of each transmitter to the ANTENNA INPUTS of the
PA821.
2. Use the 1 ft. jumper BNC-BNC cable to connect the MAIN
OUTPUT of the PA821 to the A IN of the EXPANSION PORT.
3. Connect another ANTENNA OUTPUT (from a ninth PSM trans-
mitter, second PA821 or other antenna port) to the B IN of the
EXPANSION PORT.
4. Attach an antenna to the A + B OUT of the EXPANSION PORT.
For wideband applications, use the PA805-SWB directional antenna,
Figure 3.
FIGURE 3
SPECIFICATIONS
RF Carrier Frequency Range
470-952 MHz
System Gain
+0/-5 dB
Input AC Line Voltage
100-240 Vac, 50/60 Hz
Maximum Input Line VA
100 VA
Maximum Current Drain
0.42-1.0 Amperes
(Amperes = 100 VA/Input AC Line Voltage)
Maximum RF Input Power
24 dBm (250 mW) per channel
Input Signal Indicator Threshold
+4 dBm (2.5 mW), +2 dBm (1.6 mW) typical
Impedance
50 Ωnominal
Operating Temperature Range
0° F (-18° C) to +135° F (+57°C)
NOTE: Electrical safety approval is based on a maximum
ambient temperature of 35°C.
Overall Dimensions
43.4 mm high x 398.8 mm wide x331.5 mm deep
(1 11/16 in. H x 15 11/16 in. W x 13 1/2 in. D)
Net Weight
4.53 Kg (10 lbs unpackaged, without power and RF cables)
Input/Output Connector Type
BNC-type 8 input, 1 output ACTIVE
2 Inputs, 1 output EXPANSION PORT
FURNISHED ACCESSORIES
(8) 2 ft. Coaxial Cable (RG58C/U).................................... UA802
1 ft Jumper..................................................................... 95E2035
120 VAC Power Line Cord............................................. 95A8389
230 VAC Power Line Cord............................................. 95A8247
240 VAC Power Line Cord (U.K.) .................................. 95A8713
OPTIONAL ACCESSORIES
Wideband Unidirectional Antenna (470-952 MHz) ....PA805SWB
10 ft. Coaxial Cable (RG-8X/U) ......................................... PA725
25 ft. Coaxial Cable (RG-8X/U) ........................................ UA825
50 ft. Coaxial Cable (RG-8X/U) ........................................ UA850
50Ω BNC
PSM Transmitters
AC POWER
4
ENGLISH
CERTIFICATIONS
PA821:Certified to FCC Part 74 (FCC ID No. DD4PA821). Certified in
Canada by IC to RSS-123 AND RSS-102 (Certification No. IC 616A-
PA821). UL LISTED to UL6500 (2nd Edition) and cUL LISTED to CAN/CSA
E60065-00. Meets the Essential Requirements of the European R&TTE Di-
rective 99/5/EC, eligible to bear CE mark. Meets EMC requirements of EN
301 489 Parts 1 and 9 and is GS-Certified to EN 60065 (6th Edition). Con-
forms to Australian EMC requirements, eleigible to bear C-Tick mark
(N108).
LICENSING
Changes or modifications not expressly approved by Shure Incorporat-
ed could void your authority to operate the equipment. Licensing of Shure
wireless microphone equipment is the user's responsibility, and licensabil-
ity depends on the user's classification and application, and on the selected
frequency. Shure strongly urges the user to contact the appropriate tele-
communications authority concerning proper licensing, and before choos-
ing and ordering frequencies.
THIS RADIO EQUIPMENT IS INTENDED FOR USE IN PROFES-
SIONAL ENTERTAINMENT AND SIMILAR APPLICATIONS.
NOTE: THIS EQUIPMENT MAY BE CAPABLE OF OPERATING ON
SOME FREQUENCIES NOT AUTHORIZED IN YOUR REGION.
PLEASE CONTACT YOUR NATIONAL AUTHORITY TO OBTAIN
INFORMATION ON AUTHORIZED FREQUENCIES FOR
WIRELESS MICROPHONE PRODUCTS IN YOUR REGION
Licensing: Note that a ministerial license to operate this equipment
may be required in certain areas. Consult your national authority for
possible requirements.
1) THIS DEVICE MAY NOT CAUSE INTERFERENCE, AND
2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE,
INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION OF THE DEVICE.
OPERATION OF THIS DEVICE IS SUBJECT TO
THE FOLLOWING TWO CONDITIONS:
www.shure.com
United States:
Shure Incorporated
5800 West Touhy Avenue
Niles, IL 60714-4608 USA
Phone: 847-600-2000
Fax: 847-600-1212
Email: [email protected]
©2008 Shure Incorporated
Europe, Middle East, Africa:
Shure Europe GmbH
Wannenäckestr. 28,
74078 Heilbronn, Germany
Phone: 49-7131-72140
Fax: 49-7131-721414
Email: [email protected]
Asia, Pacific:
Shure Asia Limited
Unit 301, 3rd Floor
Citicorp Centre
18, Whitfield Road
Causeway Bay, Hong Kong
Phone: 852-2893-4290
Fax: 852-2893-4055
Email: [email protected]
Canada, Latin America,
Caribbean:
Shure Incorporated
5800 West Touhy Avenue
Niles, IL 60714-4608 USA
Phone: 847-600-2000
Fax: 847-600-6446
Email: [email protected]