4
Surface Mount Microphones
Shure Microflex®MX391 Series microphones are small, surface-mounted electret
condenser microphones designed for mounting on conference tables, stage floors,
and lecterns. Their high sensitivity and wide frequency range make them especially
suitable for picking up speech and vocals in sound reinforcement and recording
applications.
• Flat frequency response across the vocal range for uncolored sound
• Interchangeable cartridges that provide a choice of polar pattern for each
application
• Sleek, low-profile design for unobtrusive appearance
• RF filtering
Model Variations
Microflex MX391 microphones are available in black or white.
The polar pattern of the included cartridge is indicated by a model number suffix:
/C Cardioid
/S Supercardioid
/O Omnidirectional
/N Cartridge not included
Interchangeable Cartridges
Microflex microphones use interchangeable cartridges that allow you to choose the
polar pattern for different installations.
Omnidirectional Supercardioid Cardioid
R183 R184 R185
Cartridge Polar Patterns
Microphone Placement
For best low-frequency response
and rejection of background
noise, place the microphone on
a large, flat surface, such as a
floor, table, or lectern.
To reduce reverberance, avoid
reflective surfaces above or to
the side of the microphone, such
as beveled sides of pulpits or
overhanging shelves.
MX395/C
130° @ -3dB
MX395/BI
2 x 90° @ -3dB
MX395/O
360°
Permanent Installation
Permanent Installation
1. Remove grille.
2. Place housing in position and
mark location of screw holes
and bottom cable exit hole.
3. Drill starter hole for each
screw and a 1/2 in. bottom
exit hole for the mic cable.
4. Insert 4-pin mini-connector and
cable through cable hole.
5. Replace grille with screw.
Do not overtighten.
Do not attempt to detach the cable from
the microphone, as damage may result.
Preamp Gain
If necessary, the preamplifier gain can be reduced by 12 dB. Contact an authorized
Shure service center for information.
R6 and R4
R13 and R16
Q8
Q9
Q2
Q6
Q1
Q5
Q3
D1
Q4
Q7
C10
C11
C6
C9
C3
C11
RFI Filtering
Important: Microphones must be used with the RK100PK and RK202PK
plate-mounted preamp to optimize RF immunity.