SETTINGS AND ADJUSTMENTS
Setting the thermostat
The thermostat is calibrated and sealed at the
factory.
Re-calibration is not authorised as it may
adversely affect the performance of the
appliance to which it is fitted and will also
invalidate warranty.
Low fire adjustment
Turn the MIN screw clockwise to decrease the
flow, anti-clockwise to increase it (calibrated
screws available on request).
Adjusting pilot gas flow
Turn the relevant screw clockwise to decrease
the flow or anticlockwise to increase it.
Adjusting the outlet pressure
(Versions with pressure regulator)
Remove the cap and turn the setting screw (A)
clockwise to increase the outlet pressure or
anticlockwise to reduce it.
Adjusting the outlet flow
(Versions with pressure regulator)
Remove the safety cap.
Turn the screw (B) clockwise to decrease the
flow or anticlockwise to increase it.
WARNING
For Minisit operation on third family gases
ensure:
- The MIN screw is replaced by a pre-drilled
version MIN screw as specified by the appliance
manufacturer. This screw must be screwed fully
home.
- The pilot adjusting screw is un-screwed two
turns from the fully closed position.
- Pressure regulator adjustment screw is
screwed fully clockwise or if an output flow
adjuster is fitted, it is screwed fully
anti-clockwise, so that they are non-operable
thereby enabling the gas supply regulator to
be ineffective.
Please ensure you follow all the guidelines detailed in the installation
and operation manual (code 9.956.710) when installing, adjusting or
operating the equipment in your possession.
A
1
B
Adjusting the outlet pressure
Adjusting the outlet flow
Low fire adjustment
IMMAGINE