Edition: 20100615 Sw 2.8 Page 6 of 9
IR301 Operation and Installation
4. NMEA Input
Accepted messages (received and transmitted) (NMEA 0183), talker identier is not processed:
Name Description Example Comments
DPT Depth $--DPT,xxxx.x,xxxx.x,xxxx.x <CR><LF>
DBT Depth below
transducer
$--DBT ,xxxx.x,f,xxxx.x,M,xxx.x,F)
DDC Display Dimming
Control
$--DDC,a,xx,*hh<CR><LF> Brightness percentage has priority over display
dimming preset.
Note: Baud rate xed to 4800 baud.
6. Service
• All service requests should be made to the local SKIPPER representative.
• Adjustments and repairs should only be performed by qualied service engineers, and unqualied repair
attempts will void the warranty.
5. Diagnostic information
• If the IR301 does not receive any signal from the external source for more than 3 seconds, “Error”
(“Err”) message is indicated on the LEDs. This may happen, for example if an external talker is not
connected or connection polarity is not correct.
• If input messages do not contain sentences required for indication of selected data, “_” (underline
symbol) is indicated on the corresponding LEDs. As an example: if there is no DBT message available
on the input, IR301 will indicate “_______” instead of depth.
• If elds in the received message is empty (not valid data), dots are indicated on the corresponding LEDs.
As an example: if the depth eld is empty in the $PSKPDPT sentence, “...” will be indicated instead of
the depth value.
NOTE: IR301 will always only indicate depth below transducer. I.e. draught is not processed.
SKIPPER Proprietary sentence
$--PSKPDPT,x.x, , , , , ,c-c*hh<CR><LF>
Transducer location. FWD/AFT
Water depth relative to transducer, meters
messages available. The LEDs for the position will shift automatically and blink every third second
indicating that the Auto selection is active. If the transducer position is unknown, both LEDs will be
on and blinking.
Note: Repeaters can be remotely dimmed by:
• Using external buttons (IR30DIM) connected to the DIM UP, DIM DN and DIMKEY of each repeater.
• Pressing up down arrows on one repeater, when DIM lines are connected in parallel.
• Using the DDC (NMEA) command as described in section 4.
SKIPPER Electronics AS