20 SKOPE Pegasus Horizontal Chiller
ELECTRONIC CONTROLLER - Controller Parameters
Controller Parameters
Programme P-470 bn1
Horizontal and Vertical Chiller - Integral and Remote
Table 7: Programme P-470 bn1
Table 7: Controller Parameters P-470 bn1 - continued
Carel Custom Controller - ELZ3333
IRSKC0HF325
Parameter Program Sheet for
BN2 BN3 BN6
e
asus - 470 - Chiller
Vert & Horizontal
- B
Access
Descri
tion of Parameter
Level Min Max Password Parameter (PS) = 66 30
/2 4- C 1 15 Measurement stabilit
4
/3 8 - C 0 15 Probe displa
speed
0
/6 0 flag F 01
Decimal point (0 = decimal point)
0
/tE 0 - C 0 6 Sensor shown on remote display
0
/P 0 - C 0 2 Type of probe (0= standard Carel NTC)
0
/A2 2 - C 0 5 Probe 2 configuration (eg 2=evap,3=cond)
2
/A3 3 - C 0 5 Probe 3 configuration (eg 2=evap,3=cond)
0
/c1 0 °C C -20°C 20°C Calibration of probe 1
0
St 2 °C F r1 r2 Temperature set point
0
rd 2 °C C 0.1°C 20°C Controller differential
2
r1 1 °C C -50°C r2 Minimum Set Point allowed
-50
r2 3.5 °C C r1 200°C Maximum Set Point allowed
60
r5 1 flag C 0 1 Enable temperature monitoring (NOT related to HACCP)
0
rt 0 Hours F 0 999 Temperature monitoring interval
0
rH 0 °C F - - Max temperature recorded during period rt
0
rL 0 °C F - - Min temperature recorded during period rt
0
c2 5 Mins C 0 15 Minimum compressor OFF time
0
c3 5 Mins C 0 15 Minimum compressor ON time
0
c4 5 Mins C 0 100 Duty setting
0
dI 6 Hours C 0 250 Interval between defrosts (if not using real time)
8
dt1 4.5 °C C -50 200 End defrost temperature, (if d0 = 0 or 1)
4
dtn 5 °C C -50 200 End defrost temperature, in Night Mode
0
dP1 60 Minutes C 1 250 Maximum defrost duration
30
d6 1 - C 0 2 Display during def.(0=dF (flash),1=locked,2=dEF)
1
dd 1 Minutes C 0 15 Dripping time after defrost
2
d8 1 Hours C 0 15 Bypass alarms after defrost
1
d8d 120 Minutes C 0 250 Graduations for Door Open Notification / Alarm (Secs)
0
A0 2 °C C 0°C 20°C Alarm and fan differential
2
AL -5 °C C -50°C 200°C Low alarm temp (see A1 for absol. or relative)
0
AH 20 °C C -50°C 200°C High alarm temp (see A1 for absol. or relative)
0
AHO 55 °C C -50°C 200°C High Ambient alarm temp (see A1 for absol. or rel.)
0
Ad 120 Minutes C 0 250 Low and high temperature alarm delay
120
A5 0 - C 0 15 Configuration of digital input 2
0
A9 9 - C 0 15 Configuration of digital input 3
0
Ac 66 °C C 0.0°C 200°C Condenser Alarm Shutdown Set Point
70
AE 11 °C C 0.1°C 20°C Cond. Warning (Divided by 2 - i.e. 10 = 5K diff from Ac)
10
F0 2 flag C 05
Evap Fan management
0
F1 20 °C C -50°C 200°C Fan start temperature
5
Fon 2 Minutes C 0 15 Time of Evap Fan On (when FO = 4)
0
FoF 2 Minutes C 0 15 Time of Evap Fan Off (when FO = 4)
0
H0 1 - C 0 207 Serial address
1
H2 1 flag C 1 6 Keypad and IR locking (1 = unlocked)
1
H4 0 flag C 0 1 Disable buzzer (0=enabled, 1 = disabled)
0
H6 8 - C 0 255 Buttons to lock when keypad locked
0
H10 0 flag C 0 15 Configuration relay AUX3
0
H17 0 flag C 0 1 Enable Probe Quick Function (0 = Enabled)
0
H18 0 flag C 0 1 Real Time Clock (RTC) Status (1 = Enabled)
0
H19 0 flag C 0 1 RTC controller alarm (1 = Enabled)
1
HAn 0 - C 0 15 Number of events HA occured
0
HA 0 - C - - Data/Time of most recent event HA
0
HA1 0 - C - - Data/Time of last event -1 HA
0
HA2 0 - C - - Data/Time of last event -2 HA
0
HFn 0 - C - - Number of events HF occured
0
HF 0 - C - - Data/Time of most recent event HF
0
HF1 0 - C - - Data/Time of last event -1 HF
0
HF2 0 - C - - Data/Time of last event -2 HF
0
HOn 0 - C - - Number of events AHO occured
0
HO 0 - C - - Data/Time of most recent event AHO
0
Htd 0 Minutes C 0 250 HACCP Activation (0 = off, >0 = ON & delay)
0
ton Set - C - - Day Mode Start (days of week, hour, minute)
0
tof Set - C - - Night Mode Start (days of week, hour, minute)
0
tc Set - C - - RTC-current time (Yr, Mth, Day of Mth, Day of Wk, Hr, Min)
0
Skope Industries Limited - Electronic Controller Parameter Sheet
Available Controller Program Modes
Program No.
Revision No.
470
BN4
Program Mode
Standard ModeNo PRN Issued
PRN Number
Date Latest Revision
20 July 2010
Date Created
7 July 2008
Defrost Parameters
Alarm Parameters
Fan Parameters
Configuration Parameters
HACCP Parameters
Real Time Clock Parameters
Recorded Parameters
Control Parameters
Compressor Parameters
BN5BN1 1.2
Display Range
Standard Mode
Settings
Probe Parameters