Operating Instructions
To turn the System On
To Adjust the Set (or desired) Room Temperature
To select the System Modes (First press of the Mode Button)
To select the Fan Mode (Second press of the Mode Button)
To select the Fan Speed (Accessed with the “Fan” Button).
With each press of the “ON” button, the ETN will toggle between “On” and “Off” mode. The ETN retains in memory the last temperature set point
and operational mode. These values are used when the ETN is turned on.
When no buttons are pressed, the LCD indicates the current room temperature. When the up (+) or down (-) buttons is first pressed the LCD will
flash rapidly and indicate the Set (or desired) room temperature. The word “SET” will also be displayed in the LCD to confirm the set temperature is
being adjusted.
When the desired set temperature is shown and there are no further button presses the LCD will stop flashing and again indicate the current room
temperature. The new desired room temperature is now active and the ETN will control the Air Conditioning system to archive this new desired
temperature.
Pressing the “Mode” button once will permit you to select the operational mode of the thermostat and by pressing the (+) or (-) buttons select these
modes. The modes available are Heat only mode, Cool only mode, Auto mode (Indicated by the words Heat & Cool in the LCD) or fan only modes.
Pressing the Mode button again will permit you to Select the Fan Control mode and select your desired fan mode by using the (+) or (-) buttons. The
two fan options are Auto Fan Mode or Continuous Fan Mode. Pressing the Mode Button again will return the ETN to normal operation.
Heat Mode: In heat mode, the thermostat will only activate the system heating when the room temperature falls below the set (or desired)
room temperature. Heat will be displayed in the LCD to indicate this mode is set. When the ETN is calling for the system to heat, the word
“HEAT” will flash slowly in the LCD. In this mode, the ETN will not turn on the Air Conditioning equipment to cool the room.
Cool Mode: In cool mode the thermostat will only activate the system cooling when the room temperature raises above the set (or
desired) temperature. Cool will be displayed in the LCD. When the ETN is calling for the system to cool, the word “COOL” will flash slowly
in the LCD. In this mode, the ETN will not turn on the Air Conditioning equipment to heat the room.
Auto Season Change over Mode: In Auto mode the thermostat will automatically activate the system heating or cooling to maintain the
set (or desired) temperature to within +/- 0.8 Deg C (approx). For example, if the set temperature is 21 deg C, the ETN will activate the
system cooling when the room temperature raises to 22 deg C and activate the system heating if the room
temperature falls to 20 deg C. The LCD will indicate Auto Season Mode by displaying both “Heat & Cool” in the
LCD. When the ETN is calling for the system to heat or cool the appropriate word will flash slowly in the LCD.
Fan only Mode: In fan only mode the ETN will only run the system fan regardless of the set and room
temperature. The ETN will not attempt to control the Air Conditioning System heating or cooling functions.
Fan only mode is typically used to improve building ventilation and not to control room temperature.
Continuous Fan Mode
In Continuous Fan mode the system fan will run 24 hours per day, but unlike the Fan Only mode described
above the ETN will also control the room temperature as dictated by the Heating, Cooling or Auto modes
set above. The ETN will indicate that this mode is active by displaying the word “Fan” in the lowest section
of the LCD.
Auto Fan Mode
In Auto Fan mode the ETN will only turn on the system fan on when there is a call for system heating or
cooling and off again when the room is at the desired temperature. The LCD will indicate that this mode
is active by displaying the words “Auto Fan” in the lowest section of the LCD.
The ETN has the ability to control the system fan through 3 fixed fan speeds. Low, Medium and High
Speed. Further in Auto fan speed mode (indicated by all three speeds being shown in the LCD) the
ETN will automatically increase or decrease the fan speed depending on the differential between
room temperature & set temperature. The Current Fan speed is Indicated by the appropriate word
flashing in the LCD.
Model ETN-HP22/3S
24 Volt Two Stage Heat Pump thermostat
with 3 Speed Fan
Auto Changeover - Non Programmable
Congratulations on the purchase of your new
Electronic Thermostat!
Your new Smart Temp ETN thermostat has been built using the best
components and design philosophy. As a consequence of this, if properly
installed your new electronic programable thermostat will provide you with
many years of trouble free and reliable service.
The Smart Temp ETN has been designed to be attractive, highly reliably and
simple to use. Please take the time to read these simple instruction to
familiarise yourself with the function and features offered in this product.
Optional Remote Control
Smart Temp
Thermostats
TM