3. The letters represent Mode type.
4. Press <Up>/ <Down> to adjust Mode type.
5. Press <ENT> to select Mode type and return to Normal Display Mode.
Function Setting Selection
1. Press and hold <Fan> and <Down> keys for 2 sec.
2. LCD changes to the display of Function setting selection.
3. The left letters represent Function type; the right letters represent Setting.
4. Press <Up>/ <Down> to adjust Function type/ Setting.
5. Press <NEXT> to select Function type/ Setting.
6. Press <ENT> to return to Normal Display Mode.
Description of the Mode types:
1. Heat only
Heat Only Mode can be used for normal-open or normal -close valves. Fan
cannot be selected.
2. Heat with fan
Heat Only Mode with Fan Selection.
3. Cool
Cool Only Mode with Fan Selection.
4. Heat Pump
Heat/ Cool/ Auto Mode can be selected with changeover valve (reversing
Valve).
(**While in Auto Mode, there is a Heat/Cool switching delay of 4 minutes for
switching a heating system to cooling system or vice versa. During the
period, neither Heater / Cooler nor Fan will turn on.)
5. Electric / gas heat with cool
Heat/ Cool/ Auto Mode can be selected. ( Default Setting)
Table of the Internal Setting:
Mode type Function type Setting
HO
Heat only HS Span of Heater 1C / 2F
2C/ 4F
dU Temperature Display Unit C
F
HF Heat with fan
HS Span of Heater 1C/ 2F
2C/ 4F
dU Temperature Display Unit C
F
FC Fan Control Method O Gas Heater– equipment controls
fan
E Electric furnace – thermostat
controls fan
CL Cool
dU Temperature Display Unit C
F
CS Span of Cool 1C/ 2F
2C/ 4F
Cd Compressor
Minimum-Off Delay
1 1 minute compressor off delay
2 2 minute compressor off delay
3 3 minute compressor off delay
4 4 minute compressor off delay
5 5 minute compressor off delay
HP Heat pump
HS Span of Heater 1C/ 2F
2C/ 4F
CO Changeover Valve C O/B terminal energized in cooling
(default)
H O/B terminal energized in heating
dU Temperature Display Unit C
F
CS Span of Cool 1C/ 2F
2C/ 4F
Cd Compressor/ Heater
Minimum-Off Delay
1 1 minute compressor off delay
2 2 minute compressor off delay
3 3 minute compressor off delay
4 4 minute compressor off delay
5 5 minute compressor off delay
SL Mode Adjustment 1 Heat, Cool, Off Selectable
2 Auto, Off Selectable
3 Heat, Cool, Off, Auto Selectable
HC
Electrical /gas
heat with cool
(Default
setting)
HS Span of Heater 1C/ 2F (Default setting)
2C/ 4F
dU Temperature Display Unit C (Default setting)
F
CS Span of Cool 1C/ 2F (Default setting)
2C/ 4F
Cd Compressor Minimum-Off
Delay
1 1 minute compressor off delay
2 2 minute compressor off delay
3 3 minute compressor off delay
44 minute compressor off delay
(Default setting)
5 5 minute compressor off delay
SL Mode Adjustment
1 Heat, Cool, Off Selectable
2 Auto, Off, Selectable
3Heat, Cool, Off, Auto Selectable
(Default setting)
FC Fan Control Method
O Gas furnace – equipment controls
fan
E Electric furnace – thermostat
controls fan
(Default setting)
F. Replaceable Batteries Instruction
Batteries shall be installed with proper polarity and
correct battery type.
Do not use old and new batteries simultaneously.
Batteries shall be removed if consumed or if product is
to be left unused for a long time. Use 1.5V/ cell ALKALINE
batteries 2 pieces.
G. Specification:
1. Temperature Measurement: 0C~40C/ 32F~99F
2. Accuracy: ±0.5C/ 1°F
3. Temperature Controllable Range:
Heat/ cool Mode:
Heat/Cool Setting: 5C~35C/ 40F~95F
Auto Mode:
Heat Setting: 5C~30C/ 40F~85F
Cool Setting: 10C~35C/ 50F~95F
4. Resolution: 0.5C/1°F
5. Power Supply: 24V~ +/-10% or 2 x AAA alkaline
batteries
6. Rating: 24V~ 50/ 60Hz 1A max
7. Terminals: 2mm
2cable
8. Operating Temperature: 0~50°C/ 32~122 °F
9. Storage Temperature: -5~50°C/ 23~122 °F
10. Sensing Element: NTC thermistor
Due to continual product improvement these specifications
are subject to change without notice.
Warranty – One Year Return to Base.