Smeg SHW800B User manual

Instructions Manual
SHW800B

2
2
INDEX
RECOMMENDATIONS AND SUGGESTIONS..................................................................................................................... 3
CHARACTERISTICS.............................................................................................................................................................4
INSTALLATION...................................................................................................................................................................... 6
USE........................................................................................................................................................................................9
MAINTENANCE...................................................................................................................................................................11
EN

EN 3
3
RECOMMENDATIONS AND SUGGESTIONS
The Instructions for Use apply to several versions of this appliance. Accordingly, you may find
descriptionsofindividualfeaturesthatdonotapplytoyourspecificappliance.
INSTALLATION
• The manufacturer will not be held liable for any damages resulting from incorrect or improper
installation.
• The minimum safety distance between the cooker top and the extractor hood is 650 mm (some
models can be installed at a lower height, please refer to the paragraphs on working dimensions
andinstallation).
• Checkthatthemains voltagecorrespondstothatindicatedontheratingplatefixedtotheinside of
thehood.
• ForClassIappliances,checkthatthedomesticpowersupplyguaranteesadequateearthing.
Connecttheextractortotheexhaust fluethrougha pipe of minimumdiameter120mm.The route
ofthefluemustbeasshortaspossible.
• Donotconnecttheextractorhoodtoexhaustductscarryingcombustionfumes(boilers,fireplaces,
etc.).
• Iftheextractorisusedinconjunctionwithnon-electricalappliances(e.g.gasburningappliances),a
sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of
exhaust gas.Thekitchenmust havean opening communicatingdirectly withthe openairinorder
to guarantee the entry of clean air. When the cooker hood is used in conjunction with appliances
supplied with energy other than electric, the negative pressure in the room must not exceed 0,04
mbartopreventfumesbeingdrawnbackintotheroombythecookerhood.
• In the event of damage to the power cable, it must be replaced by the manufacturer or by the
technicalservicedepartment,inordertopreventanyrisks.
“WARNING:Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay
resultinelectricalhazards.”
USE
• Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells.
• Neverusethehoodforpurposesotherthanforwhichithasbeendesigned.
• Neverleavehighnakedflamesunderthehoodwhenitisinoperation.
• Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not
engulfthesides.
• Deepfatfryersmustbecontinuouslymonitoredduringuse:overheatedoilcanburstintoflames.
• Donotflambèundertherangehood;riskoffire
• This appliance is not intended for use by persons (including children) with reduced physical, sen-
soryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeen givensu-
pervisionorinstructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.
• Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.
• “WARNING:Accessiblepartsmaybecomehotwhenusedwithcookingappliances.”.
MAINTENANCE
• Switch off or unplug the appliance from the mains supply before carrying out any maintenance
work.
• Cleanand/orreplacetheFiltersafterthespecifiedtimeperiod(Firehazard).
• Cleanthehoodusingadampclothandaneutralliquiddetergent.
Thesymbol on theproduct or on its packaging indicates that this product may not be treatedas household waste. Instead it
shallbehandedovertotheapplicablecollectionpointfortherecyclingofelectricalandelectronicequipment.Byensuringthisproduct
is disposed of correctly, you willhelpprevent potentialnegative consequencesfor the environment and humanhealth, which could
otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product,
pleasecontactyourlocalcityoffice,yourhouseholdwastedisposalserviceortheshopwhereyoupurchasedtheproduct.
2°

EN 4
4
CHARACTERISTICS
Components
Ref. Q.ty Product components
11 Cooker hood with control unit, lights, blower unit, filters
2.1 1 Upper chimney
2.2 1 Lower chimney
81 Air outlet grid
91 Reducer flange Ø 150-120
10 1 Damper
16 1 Cover for recycling version
Ref. Q.ty Installation components
7.2.1 2 Fixing brackets for upper chimney
11 5 Plugs
11a 2 Plugs SB 12/10
12a 5 Screws 4,2 x 44,4
12c 10 Screws 2,9 x 6,5
12e 2 Screws 2,9 x 9,5
Q.ty Documentation
1 Instruction booklet
2.1
2.2
12c
12a 7.2.1 11
11
12a
10
9
1
16
12c
12d
8
11a

EN 5
5
Dimensions
Min.
368mm
Min.
368mm

EN 6
6
INSTALLATION
Wall drilling and bracket fixing
11a
11
11
12a
11
12a
3
292 292
960 X
1÷2
7.2.1
368
743
As a first step, proceed with the following drawings:
• a vertical line up to the ceiling or up to the upper limit, at the centre of the area in which the
hood is to be fitted;
• a horizontal line at a minimum 960 mm above the cooker top.
• Mark a point (1) on the horizontal line, 292 mm to the right of the vertical reference line.
• Repeat this operation on the other side, checking that the two marks are levelled.
• Mark a reference point (3) at 743 mm above the cooker top on the vertical reference line.
• Drill at the marked points (1), using a ø 12 mm drill bit.
• Drill at the marked point(3), using a ø 8 mm drill bit.
• Insert the bracket plugs 11a into the holes (1) and tighten the screws.
• Insert plug 11 into hole (3).
• Place bracket 7.2.1 on the wall, about 1-2 mm from the ceiling or from the upper limit,
aligning the centre (notch) with the vertical reference line.
• Mark the wall at the centres of the bracket holes.
• Place the bracket 7.2.1 on the wall at X mm below the first bracket (X = height of the upper
chimney section), aligning the centre (notch) with the vertical line.
• Mark the wall at the centres of the bracket holes.
• Drill ø 8 mm holes at all the marked centre points.
• Insert the wall plugs 11 in the holes.
• Fix the brackets using the 12a screws (4,2 x 44,4) supplied with the hood.

EN 7
7
Hood body mounting
• Firstly, it is necessary to adjust the two Vr-screws of
the 11a-brackets, at minimun (B).
• Hang the hood body on the two brackets 11a.
• Connect the hood to the mains supply by means of a
bipolar switch with at least 3 mm contact gap.
• Press the “A”-key for one second (see Part USE) to
open the upper panel.
• Remove the metal filters.
• In order to align the hood it is necessary to adjust the
Vr-screws from inside the hood.
• Fasten the safety screw 11.
• Fit again the metal filters into their seats and close the
upper panel by pressing “L”-key for one second (see
Part USE).
• Disconnect the hood from the mains supply.
Attention: the upper panel stops if any barrier occurs in its
way during the panel opening or closing. To open the panel
it is enough to remove the barrier and press the key once
again.
(B)
11a
Vr
11
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150
or 120mm, the choice of which is left to the installer.
To install a ø 150 pipe
• To install the dumper 10
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
To install a ø 120 pipe
• To install a ø 120 mm air exhaust connection, insert
the reducer flange 9on the dumper 10.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove any activated charcoal filters.
ø 120
ø 150
10
10
9

EN 8
8
RECYCLING VERSION AIR OUTLET
To install the hood in recycling version, the optional
charcoal filter kit must be purchased.
• Remove the chimney angle bracket.
• Screw the filter cover onto the air outlet, using four
screws 12c (2.9 x 12.5).
• Fix the air outlet grid 8on the recirculation air outlet
using the 2 screws 12d (2,9 x 9,5) provided.
16
12c
12d
8
ELECTRICAL CONNECTION
• Connect the hood to the mains supply.
• Open the upper panel by pressing the A-key (See Part
“USE” ) for at least 2 seconds.
• Remove the metal filters (See Part “MAINTE-
NANCE”) and make sure that the connector piece of
the supply cable is correctly inside the hood socket.
Chimney assembly
Upper exhaust Chimney
• Slightly widen the two sides of the upper chimney and
hook them behind the brackets 7.2.1, making sure that
they are well seated.
• Secure the sides to the brackets using the 4 screws 12c
(2,9 x 9,5) supplied.
Lower exhaust Chimney
• Slightly widen the two sides of the chimney and hook
them between the upper chimney and the wall, making
sure that they are well seated.
• Fix the lower part laterally to the hood body using the
2 screws 12c (2,9 x 9,5) supplied.
12c
2.1
2.2
2
7.2.1
12c

EN 9
9
USE Control panel
B
AD
CEG
FI
HL
Button Function Display
A Door Closed: Press and hold for approximately 2 Sec-
onds to open the door and turn the motor on at the last
speed set.
Door Open: Press briefly to turn the motor Off or On.
Displays the set speed.
B Decrease the working speed. The number of lighted segments decreases.
C Increase the working speed. The number of lighted segments increases.
D Can only be activated with Door Open. This speed is
timed to run for 10 minutes. At the end of this time the
system will automatically return to the speed set before.
Suitable to deal with maximum levels of cooking fumes.
The indicator Iflashes and all the segments
on the Display are lit.
It is disabled by pressing the Button.
E Can only be activated with Door Open. Starts the Motor
at a speed that allows suction of 100 m3/h. Cannot be
activated if Intensive or Delay are active.
Displays 24 and the segments on the Display
all light up and then turn off one at a time in
cycle.
It is disabled by pressing the Button.
F Can be activated with motor on (except for intensive and
24 mode). Activates automatic shutdown of the Motor
and the Lighting with a 30’ delay.
Displays a flashing Clock symbol.
It is disabled by pressing the Button.
G Performs a Reset of the Filter saturation alarm when the
button is pressed for approximately 3 seconds when all
the users (motor + lights) are turned off.
After 100 hours in operation the Drop sym-
bol is displayed to indicate saturation of the
Metal Grease Filters.
After 200 hours in operation the letter Cis
displayed to indicate saturation of the Acti-
vated Charcoal filters.
H Modifies the intensity of the Lighting each time the
Button is pressed, in cycle.
I Door Closed:
When pressed and held for approximately 2 seconds
opens the door half way and turns the lighting on to
maximum intensity. The intensity can be modified using
button H.
- When the button is pressed again, the lighting turns off
and the door closes.
- Press L for door fully open, motor at speed three and
lighting on.
- When button Ais pressed the lights turn on and the
motor operates at the first two speeds only.
Door Open: Press briefly to turn the lighting On or Off.
L Door Closed: Press and hold for approximately 2 Sec-
onds to open the door, turn the motor on at speed three
and turn the lighting on at maximum intensity.
Door Open: When pressed and held for approximately 2
seconds turns off the motor and the lighting, cancelling
any function that may be active and closing the door.
Keyboard Lock: it is possible to lock the keyboard, for example when cleaning the Glass, when the Hood has Motor and
Lights turned off and when no alarms have been triggered.
Press F(Delay) for approximately 5 Seconds to enable or disable the Keyboard Lock, which is always confirmed by a
Beep and an animation on the display motor bar.

EN 1
10
REMOTE CONTROL
The appliance can be controlled using a remote control
powered by a 1.5 V carbon-zinc alkaline batteries of the
standard LR03-AAA type (not included).
• Do not place the remote control near to heat sources.
• Used batteries must be disposed of in the proper
manner.
Remote control (control panel)
T1
T6
T2
T3
T4
T5
T7
T1 Lighting Upper panel closed: opens the upper panel and sets the lights at the maximum inten-
sity.
Upper panel open: switches the lights on/off.
T2 Courtesy light Sets the lights at an intermediate intensity or switches the lights off (only when the
upper panel is open).
T3 Motor Upper panel closed: opens the upper panel, switches on the motor at the latest se-
lected speed.
Upper panel open: switches the motor on/off.
When pressed for about 2 Seconds:
upper panel closed: opens the upper panel and switches on the motor at the third
speed and the lights at the maximum intensity.
Upper panel open: switches off lights and motor and closes the upper panel.
T4 Decreases the speed at every short pressure.
When pressed for about 2 Seconds:
decreases the intensity of lights.
T5 Increases the speed at every short pressure.
When pressed for about 2 Seconds:
Increases the intensity of lights.
T6 Activates/deactivates the intensive speed.
T7 Delay / 24h Activates / deactivates the Delay-function.
When pressed for 2 seconds :
Activates/deactivates the 24H-function.

EN 1
11
MAINTENANCE
Metal grease filters
Filters can be washed in the dish machine. They need to be
washed when Drop-sign appears on the display or in any case
every 2 months, or even more frequently in case of particularly
intensive use of the hood.
Alarm reset
• Press the G–key for at least 2 seconds.
Cleaning the filters
• Open the upper panel by pressing the A-key for 1 second (see
Part USE).
• Remove the filters one by one pushing them towards the back
side of the hood unit and simultaneously pulling downwards.
• Any kind of bending of the filters has to be avoided when
washing them. Before fitting them again into the hood make
sure that they are completely dry. (The colour of the filter sur-
face may change throughout the time but this has no influence
to the filter efficiency).
• When fitting the filters into the hood pay attention that they are
mounted in correct position the handle facing outwards.

EN 1
12
Charcoal filter (recycling version)
This filter cannot be washed or regenerated. It must be replaced when the C appears on the
display or at least once every 4 months. The filter saturation alarm has to be activated already
before.
Activation of the alarm signal
• In the recycling version hoods the filter saturation alarm must be activated during the instal-
lation or later.
• Switch off the hood and the lights.
• Press the E-key for about 5 seconds until the last two segments of the motor LEDS are lit on
the display.
• By releasing the E-key the clock icon starts to flash.
• Within 3 seconds press the D-key to activate/deactivate charcoal filter saturation alarm.
• C-symbol lit - charcoal filter saturation alarm ACTIVATED.
• C-symbol unlit - charcoal filter saturation alarm DEACTIVATED.
REPLACING THE CHARCOAL FILTER
Alarm reset
• Press the G-key for at least 2 seconds.
Replacing the filter
• Open the upper panel by pressing the A-key for about a second
(see Part USE).
• Remove the metal filters.
• Remove the saturated charcoal filter as indicated (A).
• Fit the new filters as indicated (B).
• Put the metal grease filters in their seats.
A
B
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Extract the lamp from the lamp holder by pulling gently.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.

EN 1
13
Replacing the fuser
• The fuser is placed up on the right side. Turn the
fuser holder as indicated. Replace the fuser with one
having the same features.



991.0266.554_ver1
Table of contents
Other Smeg Ventilation Hood manuals
Popular Ventilation Hood manuals by other brands

Thermador
Thermador H Series Care and use instructions

Sirius Satellite Radio
Sirius Satellite Radio SLT960 Installation, use and maintenance instructions

Monogram
Monogram ZV48T installation instructions

KOBE
KOBE CXX8130QF-GBK-1 Installation instructions and operation manual

ELICA
ELICA EGL436S1 Use, care and installation guide

Ancona
Ancona WPRV430 User's manual & installation instructions