Smeg SHWG910X User manual

Instructions Manual
SHWG910X

2
2
INDEX
RECOMMENDATIONS AND SUGGESTIONS..................................................................................................................... 3
CHARACTERISTICS.............................................................................................................................................................4
INSTALLATION...................................................................................................................................................................... 5
USE........................................................................................................................................................................................8
MAINTENANCE.....................................................................................................................................................................9
EN

EN 3
3
RECOMMENDATIONS AND SUGGESTIONS
The Instructions for Use apply to several versions of this appliance. Accordingly, you may find
descriptionsofindividualfeaturesthatdonotapplytoyourspecificappliance.
INSTALLATION
• The manufacturer will not be held liable for any damages resulting from incorrect or improper
installation.
• The minimum safety distance between the cooker top and the extractor hood is 650 mm (some
models can be installed at a lower height, please refer to the paragraphs on working dimensions
andinstallation).
• Checkthatthemains voltagecorrespondstothatindicatedontheratingplatefixedtotheinside of
thehood.
• ForClassIappliances,checkthatthedomesticpowersupplyguaranteesadequateearthing.
Connecttheextractortotheexhaust fluethrougha pipe of minimumdiameter120mm.The route
ofthefluemustbeasshortaspossible.
• Donotconnecttheextractorhoodtoexhaustductscarryingcombustionfumes(boilers,fireplaces,
etc.).
• Iftheextractorisusedinconjunctionwithnon-electricalappliances(e.g.gasburningappliances),a
sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of
exhaust gas.Thekitchenmust havean opening communicatingdirectly withthe openairinorder
to guarantee the entry of clean air. When the cooker hood is used in conjunction with appliances
supplied with energy other than electric, the negative pressure in the room must not exceed 0,04
mbartopreventfumesbeingdrawnbackintotheroombythecookerhood.
• In the event of damage to the power cable, it must be replaced by the manufacturer or by the
technicalservicedepartment,inordertopreventanyrisks.
“WARNING:Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay
resultinelectricalhazards.”
USE
• Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells.
• Neverusethehoodforpurposesotherthanforwhichithasbeendesigned.
• Neverleavehighnakedflamesunderthehoodwhenitisinoperation.
• Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not
engulfthesides.
• Deepfatfryersmustbecontinuouslymonitoredduringuse:overheatedoilcanburstintoflames.
• Donotflambèundertherangehood;riskoffire
• This appliance is not intended for use by persons (including children) with reduced physical, sen-
soryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeen givensu-
pervisionorinstructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.
• Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.
• “WARNING:Accessiblepartsmaybecomehotwhenusedwithcookingappliances.”.
MAINTENANCE
• Switch off or unplug the appliance from the mains supply before carrying out any maintenance
work.
• Cleanand/orreplacetheFiltersafterthespecifiedtimeperiod(Firehazard).
• Cleanthehoodusingadampclothandaneutralliquiddetergent.
Thesymbol on theproduct or on its packaging indicates that this product may not be treatedas household waste. Instead it
shallbehandedovertotheapplicablecollectionpointfortherecyclingofelectricalandelectronicequipment.Byensuringthisproduct
is disposed of correctly, you willhelpprevent potentialnegative consequencesfor the environment and humanhealth, which could
otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product,
pleasecontactyourlocalcityoffice,yourhouseholdwastedisposalserviceortheshopwhereyoupurchasedtheproduct.
2°

EN 4
4
CHARACTERISTICS
Dimensions
253
min. 850
max. 1050
740
132
90
433
Min.
500mm
Min.
650mm
Components
Ref. Q.ty Product Components
11 Hood Body, complete with: Controls, Light, Blower,
Filters
21 Telescopic Chimney comprising:
2.1 1 Upper Section
2.2 1 Lower Section
91 Reducer Flange ø 150-120 mm
10 1 Damper
14.1 2 Air Outlet Connection Extension
15 1 Air Outlet Connection
Ref. Q.ty Installation Components
7.2.1 2 Upper Chimney Section Fixing Brackets
11 6 Wall Plugs
12a 6 Screws 4,2 x 44,4
12c 6 Screws 2,9 x 9,5
Q.ty Documentation
1 Instruction Manual
2.1
2.2
2
9
14.1
15
12c
12a 7.2.1 11
1
11
12a
1
10

EN 5
5
INSTALLATION Wall drilling and bracket fixing
11
12a
330 X
116
1÷2
116
650 min.
7.2.1
Wall marking:
• Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the
centre of the area in which the hood will be installed.
• Draw a horizontal line at 650 mm above the hob. Place bracket 7.2.1 on the wall as shown
about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical
reference line.
• Mark the wall at the centres of the holes in the bracket.
• Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the
upper chimney section supplied), aligning the centre (notch) with the vertical line.
• Mark the wall at the centres of the holes in the bracket.
• Mark a reference point as indicated at 116 mm from the vertical reference line and 330 mm
above the horizontal reference line.
• Repeat this operation on the other side.
• Drill ø 8 mm holes at all the centre points marked.
• Insert the wall plugs 11 in the holes.
• Fix the brackets using the 12a (4,2 x 44,4) screws supplied.
• Insert the two screws 12a (4,2 x 44,4) supplied in the hood body fixing holes, leaving a gap
of 5-6 mm between the wall and the head of the screw.

EN 6
6
Mounting the hood body
• Before attaching the hood body, tighten the two screws Vr lo-
cated on the hood body mounting points.
• Hook the hood body onto the screws 12a.
• Fully tighten the support screws 12a.
• Adjust the screws Vr to level the hood body.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120mm, the
choice of which is left to the installer.
To install a ø 150 pipe
• To install the dumper 10
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
To install a ø 120 pipe
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9on the dumper 10.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove any activated charcoal filters.
9
ø 120ø 150
10
10
RECIRCULATION VERSION AIR OUTLET
• Push fit connection 15 onto the hood body outlet.
• Insert the connection extension pieces laterally 14.1 in connec-
tion 15.
• Make sure that the outlet of the extension pieces 14.1 is hori-
zontally and vertically aligned with the chimney outlets. If this
is not the case, adjust the position by either reversing the con-
nection extension pieces 14.1 and then reassemble as described
previously.
• Ensure that the activated charcoal filters have been inserted.
14.115

EN 7
7
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.
Chimney assembly
Upper exhaust Chimney
• Slightly widen the two sides of the upper chimney and hook
them behind the brackets 7.2.1, making sure that they are well
seated.
• Secure the sides to the brackets using the 4 screws 12c (2,9 x
9,5) supplied.
Lower exhaust Chimney
• Slightly widen the two sides of the chimney and hook them
between the upper chimney and the wall, making sure that they
are well seated.
• Fix the lower part laterally to the hood body using the 2 screws
12c (2,9 x 9,5) supplied.
12c
2.1
2.2
2
7.2.1
12c

EN 8
8
USE
L T1 T2 T3 T4
L1 L2 L3 L4
Control panel
Button Function Led
L Turns the lighting system on and off. -
Press and hold for approx. 2 seconds to turn
the lighting system on and off at reduced
intensity.
-
T1 Turn the suction motor on and off at speed
one. On.
Press and hold the button for approximately
2 seconds, with all the loads turned off
(Motor and Lights), to reset the Filters and
turn off the Leds that are lit.
After 100 working hours all the LEDs (L1-
L2-L3-L4) will light up and remain lit to
indicate saturation of the metal grease filters.
After 200 working hours all the LEDs (L1-
L2-L3-L4) will light up and start to flash to
indicate saturation of the activated charcoal
filters.
T2 Turn the suction motor on at speed two. On.
Press and hold for approximately 5 seconds,
with all the loads turned off (Motor and
Lights), to enable/disable the Remote
control.
2 flashes, Remote control Enabled.
1 flash, Remote control Disabled.
T3 Turn the suction motor on at speed three. On.
Press and hold the button for 2 seconds to
activate intensive speed. This speed is timed
to run for 10 minutes. At the end of this
time the system will automatically return to
the speed set before.
T4 Press and hold the button for approximately
2 seconds to activate automatic shutdown
with a 30' delay (Motor+Lights).
On.
Press and hold for approximately 5 seconds
to enable/disable the Activated Charcoal
Filter alarm.
2 Flashes of the Leds (L1-L2-L3) Filter
Alarm Enabled.
1 Flash of the Leds (L1-L2-L3) Filter Alarm
Disabled.

EN 9
9
MAINTENANCE
Metal grease filters
These can also be washed in the dishwasher, and need to be
cleaned when all the command LEDs light up in a continuous
manner or at least once every 2 months use, or more frequently if
use is particularly intensive.
Resetting the alarm signal
• Press button T1 (see the paragraph on Use).
Cleaning the Filters
• Remove the Filters one at a time, pushing them towards the
back of the unit and at the same time pulling downward.
• Wash the Filters without bending them, and leave them to dry
completely before replacing.
• Replace, taking care to ensure that the handle faces forwards.

EN 1
10
Activated Charcoal Filter (Recirculation Version)
• This cannot be washed or regenerated, and must be changed when all the command LEDs
start to flash, or at least once every 4 months.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at
a later date.
• Press and hold the Delay button (T4) on the keypad for 5 seconds and the following will be dis-
played:
• Leds (L1-L2-L3) flash twice – Activated Charcoal Filter saturation alarm ACTIVATED.
• Leds (L1-L2-L3) flash once – Activated Charcoal Filter saturation alarm DEACTI
VATED.
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• Press button T1 (see the paragraph on Use).
Changing the Filter
• Remove the Metal grease filters.
• Remove the saturated Activated Charcoal filter, as shown in
the figure.
• Fit the new Filter, hooking it into place.
• Replace the Metal grease filters.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the snap-on lamp cover by levering it from under the
metal ring, supporting it with one hand.
• Remove the halogen lamp from the lamp holder by pulling
gently.
• Replace the lamp with a new one of the same type, making
sure that you insert the two pins properly into the housings on
the lamp holder.
• Replace the snap-on lamp cover.


436006009_ver2
Table of contents
Other Smeg Ventilation Hood manuals