SOMFY inteo CENTRALIS UNO RTS VB User manual

Trouble shooting guide
CENTRALIS UNO RTS VB is a individual control system for AC motor dedicated to external and
interior venetian blind applications.
•
CENTRALIS UNO RTS VB has an integrated radio receiver compatible with the RT
and RTS transmitters allowing individual, group and master commands. Up to twelve controls can
be recorded in the CENTRALIS UNO RTS VB.
•
The commands coming from the radio controls can be disabled thanks to the 0/auto switch.
• An automatic intermediate position and a slat tilting operation can be programmed.
• CENTRALIS UNO RTS VB is compatible with the EOLIS and SOLIRIS sensors RTS.
Up to three RTS sensors can be memorized in one receiver and one RTS sensor can be memori-
zed in several receivers.
inteo
CENTRALIS UNO RTS VB
INSTALLATION
guide
Ref.5005937A
80 mm
80 mm
33 mm 17 mm
•Main supply : 220-240V 50Hz.
•Class II product
•Protection index IP40.
•Output : 250V~ 3A
•Output temporisation : activ for 180s.
•Environmental conditions for use :
- temperature +5°C to +40°C (no condensation allowed).
- pollution degree typical for usual living space.
This device must be installed and programmed by qualified installers for whom this instruction is inten-
ded.
Before connecting the unit, read the instructions carefully.
We reserve the right to make changes due to technical improvements.
1
CENTRALIS uno RTS VB
FRONT PLATE
CONTROL UNIT FRAME BRACKET
WALL
1
Characteristics
2
Installation
The range of radio control is limited by laws regulating
radio devices and by building design.
When planning, please ensure that there is adequate radio
reception.
In order not to affect quality of reception, a minimum
distance of 30 cm between a CENTRALIS uno RTS VB
and a radio transmitter should be maintained.
CENTRALIS uno RTS VB should not be installed in the
immediate vicinity of metal surfaces. Powerful local trans-
mitter equipment (e.g. cordless headphones) with a trans-
mission frequency identical to the CENTRALIS uno RTS
VB can affect its function.
Hereby, SOMFY, declares that this equipment
is in compliance with the essential require-
ments and other relevant provisions of
Directive 1999/5/EC.
A Declaration of Conformity is available at the
web address www.somfy.com Heading CE
We reserve the right to make changes due to technical improvements.
CENTRALIS uno RTS VB
4
Nothing works:
§Check the wiring.
§Check the battery of the transmitter.
§Check that the transmitter has been properly recorded.
§Check for any other possible source of radio interferences.
Lost in your programming mode:
§Just make a complete reset and start again
(refer to section 5).
• Move the blind at its UP limit with
the ▲button and immediately press
the ■button briefly.
• Press the ▼and ■button simulta-
neously until the blind begins to move
DOWN.
• Stop the blind at the intermediate
position you wish.
If necessary, adjust this position with
the ▲or ▼buttons.
• Press the ■button more than 5 sec.
➜The blind jogs briefly (UP/DOWN),
the intermediate position is recorded.
• Press simultaneously on the ▲
and ■button until the blind begins
to move briefly UP.
• Move the blind downward to get
the slats closed.
• Adjust the tilt angle with the
▲or ▼buttons.
• Press the ■button more than 5 sec.
➜The blind jogs briefly (UP/DOWN), the
tilt angle is recorded.
after
3 seconds STOP IP
• Press briefly the ■button while the
blind is at its UP limit.
➜The blind will move and stop at the
intermediate position.
• Press briefly the ■button while the blind is at its UP limit.
➜The blind will move, stop at the intermediate position and tilt at
the pre-set angle.
Note : after a DOWN movement the blind only tilts.
• Press briefly the ■button while the blind
is closed (after a DOWN movement).
➜The blind will tilt at the pre-set angle.
Note : after an UP movement the blind
does not tilt.
adjust
the angle
Set the blind to its UP limit before programming in order to always have the same adjustment.
If IP only has been programmed If tilting only has been programmed If both IP and tilting have been programmed
2
13
12 3
4
4
5 sec.
5 sec.
Phantom intermediate position/slat tilting:
§The programmed IP can only be reached from the UP limit.
not when the blind is in another position.
§Be sure to adjust the slat tilting after a down movement
when the blind is approximately 3/4 down of the window.
after
3 seconds or
UP
UP limit
UP limit
tilting
tilting IP
IP
SOMFY SAS, capital 20.000.000 Euros, RCS Bonneville 303.970.230
Assembly
2.1
Programming the intermediate position (IP)
a
Programming the automatic slat tilting
b
Operating
c
If you record a new IP or a new tilting function, this will automatically erase the previous one.
If you want to erase without recording a new one, Press briefly on the ■button to reach the IP or to get the tilting (or both), then:
§To erase the intermediate position, press the ▼and ■buttons simultaneously for more than 5 seconds.
§To erase the tilting, press the ■and ▲buttons simultaneously for more than 5 seconds.
§To erase both, just press the ■button for more than 5 seconds.
➜The blind jogs briefly (UP/DOWN) indicating that CENTRALIS uno RTS VB has deleted the intermediate position and/or the tilting.
Delete the intermediate position/automatic tilting
d
5
Complete reset
To completely reset the CENTRALIS uno RTS VB, press its PROG button for more than 7 seconds.
This will erase all of the programmed controls, the intermediate position and the automatic tilting.
➜The blind jogs briefly (UP/DOWN), the memory of the CENTRALIS uno RTS VB is cleared.
P
R
O
G
7 sec.
usable in EU, CH

We reserve the right to make changes due to technical improvements.
CENTRALIS uno RTS VB
2
GROUP CONTROL (one transmitter for several receivers)
To program one control in several CENTRALIS uno RTS VB, set all the receivers in their programming mode then repeat the same procedure.
It is recommended not to use a RT control as a general control point.
To record several RTS controls in CENTRALIS uno RTS VB, repeat the same procedure as described in section 3.1 for each control.
You can also use an already recorded control to set the
CENTRALIS uno RTS VB
in its programming mode
RTS control : press for more than 2 sec. on the “prog” button.
RT control : remove the battery, press briefly the button, replace the battery and press for more than 2 sec. on the button.
➜The LED of the CENTRALIS uno RTS VB lights on and the blind jogs briefly UP and DOWN indicating that the
CENTRALIS uno RTS VB is in programming mode and that you can record a new control.
You can program up to 12 controls to one receiver. If you try to enter a 13th, your instruction will be ignored.
CENTRALIS uno RTS can be operated by its push-buttons or with a RT/RTS control.
CENTRALIS uno RTS VB offers two different modes to control the venetian blind.
P
R
O
G
MAINS
230V - 50Hz
3 wires x 1,5 mm2
4 wires x 0,75 mm2
Neutral
Earth
Phase
123456
5 wires x 1,5 mm2
NL
N
Centralis uno RTS
Junction box MotorSupply
Phase
Neutral
Earth Earth (green/yellow)
Common (blue)
Up (black or brown)
Down (black or brown)
L➜
N➜
N
▲
▼
1
2
3
4
5
6
NL
N
SUPPLY
230V 50Hz
Phase
Neutral
Earth
LT motor
DOWN
PE
N
UP
•disconnect mains before carrying out any work.
•ensure that no forces act on the screw terminals after installation.
3
Radio programming
Set the CENTRALIS uno RTS VB in
its programming mode by pressing the
PROG button until the blind jogs briefly
(UP/DOWN).
The CENTRALIS uno RTS VB will
remain ready to record a control for two
minutes.
P
R
O
G
➜
2 sec.
3V
LITHIUM
RENATA
CR2032
3V
LITHIUM
RENATA
CR2032
S
W
I
S
S
M
A
D
E
3V
LITHIUM
RENATA
CR2032
3V
LITHIUM
RENATA
CR2032
S
W
I
S
S
M
A
D
E
0,5 s
0,5 s 0,5 s
We reserve the right to make changes due to technical improvements.
3
CENTRALIS uno RTS VB
Press the prog button of the
CENTRALIS uno RTS VB
to enter in programming mode, then press shortly the prog button of the RTS
control you wish to remove.
It is also possible to set the
CENTRALIS uno RTS VB
in its programming mode with another RTS control (see 3.2), then press
shortly the prog button of the RTS control you wish to remove.
To remove all the controls, do a complete reset of the
CENTRALIS uno RTS VB
(see section 5).
4
Operating
“auto” position :
All commands from the push buttons of the CENTRALIS uno RTS VB (local control) and from the radio
controls (master control) are taken into account.
“0” position :
Only the push button commands are taken into account and the radio commands are disabled (This feature
allows to isolate a room from the master control). To force the control of the CENTRALIS uno RTS VB with
radio, the radio command should be longer than 2 sec.
In association with the SOLIRIS/EOLIS sensors RTS or a CHRONIS RTS light,
CENTRALIS uno RTS VB is able to control and protect the blind according to the sun
and wind conditions.
To record a SOLIRIS/EOLIS RTS sensor or a CHRONIS RTS light in the CENTRA-
LIS uno RTS VB, repeat the same procedure as describe in section 3.2 (record a new
control).
Refer to the instruction manual of the relevant products for the programming and set-
ting procedures.
➜
The blind jogs briefly (UP/DOWN)
and the LED of the CENTRALIS
uno RTS VB blinks during 5 secs.
indicating that the control has been
recorded.
CENTRALIS uno RTS VB
quits its
programming mode.
RTS control
Press briefly the program-
ming button on the RTS
control you wish to record.
RT control
Remove the battery, press
briefly the button, replace the
battery and press again briefly
the button.
UP/DOWN/STOP/TILT commands
4.1
0/auto switch
4.2
Wind/Sun/Light functions
4.3
Remove a control (on an existing installation)
3.3
Initial installation : record the first control
3.1
Record new controls
3.2
Wiring
2.2
US mode (factory mode)
§Press briefly the ▼or ▲buttons to raise or lower the blind.
§Press briefly the ■button To stop the blind.
§To tilt the slats, press and hold the ▼or ▲buttons.
If you hold the control buttons for more than 6 seconds, the blind
will start to move continuously up to its end limits.
EU mode :
§To raise or lower the blind, press and hold more than 2 secs. the ▼
or ▲buttons.
§To stop the blind, press briefly the ■button.
§To tilt the slats, press briefly the ▼or ▲buttons.
UP button
0/auto switch
STOP/IP button
DOWN button
The configuration can be changed by pressing for more than 5 secs. on the ■button of a RTS control just after the power on. The
blind jogs, indicating that CENTRALIS uno RTS VB has changed the configuration.
With the CENTRALIS uno RTS VB, it is possible to program an automatic intermediate position (IP) and an automatic tilting of the
slats. You can choose to program one or the other, or both. The recording of the intermediate position and the tilting can be made
from the CENTRALIS uno RTS VB or from a RTS control.
Intermediate position / automatic slat tilting
4.4
12
Other SOMFY Control System manuals
Popular Control System manuals by other brands

Watts
Watts OneFlow OFPSYS EU Installation and operation manual

Roland
Roland R1000 series E20 manual

Lenz
Lenz Digital Plus SET010 First steps

WPM
WPM 0792 Instructions for installation and operation

Nordyne
Nordyne Airzone iQ Zone user manual

RF SOLUTIONS
RF SOLUTIONS ESPRIT LOW VOLTAGE Series quick start guide