Varifan VPM-1 User manual

VPM-1
User’s Manual
www.monitrol.com

Although the manufacturer has made every effort
to ensure the accuracy of the information
contained herein, this document is subject to
change without notice due to ongoing product
development.
WARNINGS AND PRECAUTIONS
Equipment, probe failure, blown fuses and/or
tripped breakers may prove harmful to the
contents of the building. Therefore it is strongly
recommended to install backup devices and alarm
or warning devices. Spare equipment should also
be available at the owner’s site. Equipment
manufactured by the manufacturer is protected
against normal line surges. High surges caused
by thunder storms or power supply equipment
may damage this equipment. For added security
against line voltage surges it is recommended that
surge and noise suppression devices be installed
at the electrical distribution panel. Use of shielded
cable for probes is recommended for protection
against lightning. These devices are available
from most electrical supply distributors.
RECOMMENDATIONS
The manufacturer recommends that all installation
procedures described herein be performed by a
qualified electrician or installation technician.
Further more the manufacturer recommends to
test all the functions and equipment connected to
the VPM, including the alarm system and backup
devices, after installation, after changes to the
installation and every month after that.
Fuse verification and replacement, as well as the
proper setting of control values shall be the
responsibility of the owner of this equipment.
www.monitrol.com

Page 3
INTRODUCTION
1. General ........................................................................... 4
1.1 Description....................................................................... 4
INSTALLATION
2.1 Unpacking........................................................................ 6
2.2 Mounting.......................................................................... 6
2.3 Connection Procedure..................................................... 7
2.3.1 Cabling ............................................................................ 7
2.3.2 Connecting 115 VAC Fan................................................ 7
2.3.3 Connecting 230 VAC Fan................................................ 7
2.3.4 Connecting to the master control..................................... 8
2.4 Powering Up .................................................................... 8
USER’S GUIDE........................................................................... 12
APPENDIX
Troubleshooting........................................................................... 14
Specifications .............................................................................. 14
TABLE OF CONTENTS
www.monitrol.com

Page 4
VPM-1
1. GENERAL
This document provides a description of the VPM-1
unit. This document is organized as follows:
•Introduction
•Installation
•User’s Guide
•Appendix
1.1 DESCRIPTION
The VPM-1 is designed to drive one variable speed fan
of up to 6 amp per stage, under the master control ( LX
or IC) system resulting in a clean air environment for
your livestock.
The VPM-1 provides you with automated control over
its one stage via the use of the master control.
The manufacturer recommends that the following
installation instructions very closely, and that all
work be performed by a certified electrician. Failure
to do so may void the warranty!
www.monitrol.com

Page 5
INSTALLATION
INSTALLATION
www.monitrol.com

Page 6
VPM-1
2.1 UNPACKING
Unpack the VPM-1 from its box and inspect contents for
damage. Should the contents appear to be damaged,
contact your local distributor for return material
procedures.
The package should contain the following standard
items:
•1 VPM-1 control
•1 cable fastener or fuse
•1 user’s manual
2.2 MOUNTING
Mount the unit to the wall using the mounting holes
located on the flange of the control housing.
Once the VPM-1 is in place, use a screwdriver to
remove the four screws holding the faceplate to the
housing.
To limit the unit’s exposure to noxious gases install
To limit the VPM-1’s exposure to noxious gases,
install the unit in a hallway.
Make sure the VPM-1 is properly installed, that is,
side up with the cable entry holes facing down. DO
NOT DRILL ADDITONNAL HOLES INTO THE
ENCLOSURE.
The VPM-1 operates in a temperature range of 0°C
(32°F) to 50°C (122°F).
The enclosure is watertight, but not splash proof or
immersion proof. DO NOT CLEAN WITH HIGH
PRESSURED WATER. Cover it carefully with plastic
when cleaning the room.
Install in an area protected from sunlight.
It is prohibited to use overhead cables outside the
building.
www.monitrol.com

Page 7
INSTALLATION
2.3 CONNECTION PROCEDURE
For the connection procedures which follow refer to
Figures 1 and 2.
2.3.1 - Wiring
Use a screwdriver to remove cable knock-outs for the
installation of cabling to the unit. Knock-outs may be
difficult to remove, drill out if possible.
It is strongly recommended to install PVC conduits.
Make sure that the cables are water tight.
2.3.2 - Connecting 115VAC Fans
Refer to figure 1.
•Connect L1 of the power source to terminal 1 for fan 1.
•Connect the ground wire of the power source to the
ground wire in the housing of the unit.
•Connect the neutral side of the power source to the
neutral of fan 1.
•Connect the live lead of fan 1 to terminal 2.
2.3.3 - Connecting 230VAC Fans
Refer to figure 2.
•Connect L1 of the power source to terminal 1 for fan 1.
•Connect the ground wire of the power source to the
ground wire in the housing of the unit.
•Connect L2 of the power source to the appropriate
terminals of fan 1.
•Connect the appropriate lead of fan 1 to terminal 2.
Do not apply power to the control panel until all con-
nections have been completed!
Maximum load of 10 amps per stage only.
www.monitrol.com

Page 8
VPM-1
2.3.4 - Connecting to the master control
•Install a 18 - 22 AWG cable pair between the VPM-
1 and the LX control. The maximum cable length is
of 500 feet (150m).
•Connect one end of the cable to the (+) and (-)
terminals of the VPM-1 low voltage terminal block.
Refer to the bottom left corner of figures 1 or 2.
•All wires between the master control and the VPM-
1, as well as the probes should be shielded.
•Do not place low voltage cable into power conduit.
2.4 POWERING UP
Before powering up the VPM-1,
•Screw the faceplate to the casing of the unit using
the four screws previously removed.
•Verify the fan’s motor specifications. The current
must not exceed 10 A per stage
•To test the unit use the manual override parameter
indicated on the master control.
•When you have completed verifying the fan
operation, set the manual override parameter on
the master control to AUTO.
When using 3 phase power, ensure that the
phase supplying the master control and variable
fan is the same. Otherwise the control signal of
the master control will be too early or too late and
the fan will not rotate as expected.
CAUTION
www.monitrol.com

Page 9
INSTALLATION
Figure. 1
Main Board: Connection of 115 VAC source and 115 VAC fan
Notes for Figure 1
Power cut and protection devices in case of overload.
Connect the grounding wire from the power cord to the
ground terminal wire inside the housing.
1
2
www.monitrol.com

Page 10
VPM-1
Figure. 2
Main Board: Connection of 230 VAC source and 230 VAC fan
Notes for Figure 2
Power cut and protection devices in case of overload.
Connect the grounding wire from the power cord to the
ground terminal wire inside the housing.
1
2
www.monitrol.com

Page 11
USER’S GUIDE
USER’S GUIDE
www.monitrol.com

Page 12
VPM-1
The VPM-1 is a single variable speed unit able to drive
one or several fans in a single stage. The fan speed is
controlled accordingly to the logic of the master control,
the LX or IC control.
The VPM-1 can be controlled manually from the master
control to:
•be turned OFF,
•run a variable speed fan from 0 to 100%,
•run automatically following the master control
logic.
www.monitrol.com

Page 13
APPENDIX
APPENDIX
www.monitrol.com

Page 14
VPM-1
NO
NOYES
TROUBLESHOOTING
Description Value
STAGE 1
−10 AMP 115/230 VAC
−50/60 Hz
−Fuse 15A SLO-BLO
SPECIFICATIONS
Storage
Temperature: 0°C to 70°C (32°F to 122°F).
Operation
temperature: 0°C to 50°C (32°F to 158°F).
Weight: 3 pounds (1.35Kg)
Dimension: 7.75”x5.75”x4” (196x146x101mm)
YES
Set the manual override
parameter to AUTO in the
master control.
The unit
is OK.
Adjust setting of the LX or
IC to allow fans to operate.
Are the fan (s) operating?
Verify the power connection
to the VPM-1 fuses, and
fans. Also the low voltage
cable between the LX or IC
and the VPM.
Are the fan (s) operating?
Contact
your
dealer for
service.
www.monitrol.com

WARRANTY
Limited Warranty
The manufacturered equipment and supplied
components have gone through rigorous inspection to
assure optimal quality of product and reliability.
Individual controls are factory tested under load,
however the possibility of equipment failure and/or
malfunction may still exist.
For service, contact your local retailer or supplier. The
warranty period shall be for two years from
manufacturing date. Proof of purchase is required for
warranty validation.
In all cases, the warranty shall apply only to defects in
workmanship and specifically exclude any damage
caused by over-voltage, short circuit, misuse, acts of
vandalism, fortuitous events, acts of God, flood, fire,
hail, lightning or any other natural disaster. Any
unauthorized work, modification or repair on this
product automatically voids the warranty and
disclaims the manufacturer from all responsibility.
The manufacturer assumes only those obligations set
forth herein, excluding all other warranties or
obligations. This warranty stipulates that in all cases
the manufacturer shall be liable only for the supply of
replacement parts or goods and shall not be liable for
any personal injury, damages, loss of profits,
interrupted operations, fine contravention of the law or
damages to the production of the PURCHASER and
the PURCHASER shall take up the defense and hold
the manufacturer faultless regarding any legal or
extra legal proceedings, notice, or claim by the
customer or by a third party, and regarding any legal
and extra legal expenses and fees brought forward on
by such damages.
www.monitrol.com

MAV VPM-1 VER:2.1
JUNE 22,2001
www.monitrol.com
Table of contents
Other Varifan Control System manuals

Varifan
Varifan IC-610 User manual

Varifan
Varifan MSC-10 User manual

Varifan
Varifan DIP-1C Operation manual

Varifan
Varifan IC-68ND User manual

Varifan
Varifan ECS 5M User manual

Varifan
Varifan IC-664 User manual

Varifan
Varifan CPS-3M User manual

Varifan
Varifan ECS-4+ User manual

Varifan
Varifan CM10-2 User manual

Varifan
Varifan ECS-2M User manual