Soyal AR-721U User manual

AR-721U/721K/661U
User’s Guide
Feb. 6, 2004

1
Table of Contents
Page
1. Main Feature --------------------------------- 3
2. AR-721U Installation --------------------------------- 4
2.1 Steps --------------------------------- 4
2.2 Installation Notice --------------------------------- 5
2.3 Wiring --------------------------------- 6
2.4 PCB board ----------------------------------8
2.4.1 No waterproof --------------------------------- 8
2.4.2 Waterproof --------------------------------- 8
2.5 Installation diagram ----------------------------------9
2.5.1 AR-721U & AR-721H ------------------- 9
2.5.2 AR-721U & AR-727H ------------------- 10
2.5.3 AR-721U & AR-821EF ------------------- 11
2.5.4 AR-721U & AR-829E ------------------- 12
3. AR-721K Installation -------------------------------- 13
3.1 Steps -------------------------------- 13
3.2 Installation Notice -------------------------------- 14
3.3 Wiring -------------------------------- 15
3.4 PCB board -------------------------------- 16
3.5 Installation diagram -------------------------------- 17
3.5.1 AR-721K & AR-721H ------------------- 17
3.5.2 AR-721K & AR-727H ------------------- 18
3.5.3 AR-721K & AR-821EF ------------------- 19
3.5.4 AR-721K & AR-829E ------------------- 20

2
4. AR-661U Installation -------------------------------- 21
4.1 Installation Notice -------------------------------- 21
4.2 Wiring -------------------------------- 22
4.3 Installation diagram -------------------------------- 23
4.3.1 AR-661U & AR-721H ------------------- 23
4.3.2AR-661U & AR-727H ------------------- 24
4.3.3AR-661U & AR-821EF ------------------- 25
4.3.4AR-661U & AR-829E ------------------- 26
4.4 The standalone controller do anti-pass-back with
2 pcs of AR-661U -------------------------------- 27
4.5 Testing table of AR-661U Reading Range depends
on tags -------------------------------- 29
5 Troubleshooting -------------------------------- 30
6 Return of Products -------------------------------- 30
7 Warranty -------------------------------- 31

3
1.MainFeatures
Easily integrated with soyal or other access control systems.
Programmable various outputs formats Wiegand, magstripe or
serial.
Built-in watchdog to prevent the system from halting
A bi-color LED indicator and a beep sound.
Item AR-721U AR-721K AR-661U
Reading Range
(Depends on tags)
About 8 cm About 15 cm 33-60 cm
Output Formats WG 26 / 34, ABA II, ASYNC 9600, N, 8, 1
Voltage 9-18VDC
Current < 1W < 2.5W < 4W
RF Frequency 125KHz
Environment -10℃to +50℃
LED Indicators ●●●
Beep Sound ●●●
Keypad X 12 Keys X
Material ABS ABS ABS
Waterproof Option X ●
Dimensions (mm) 80(L)×43(W)×15(H) 112(L)*76(W)*25(H) 230(L)*230(W)*35(H)

4
2. AR-721U Installation
2.1 Steps
1. Use the screwdriver to screw the mounting plate on the wall.
2. Pull cable ends through the access hole in the mounting plate.
AR-721U must be connected before power is applied to the
single door controller.
3. Attach the AR-721U to the mounting plate.
4. Apply power. The red LED will flash once and the beeper will
sound.

5
2.2 Installation Notice
1. AR-721U is narrow enough to mount to most mullions and door
frames.
2. Single door controller locate inside the secure area for use as an
exit controller, the auxiliary reader locate exterior wall for use as
an entrance reader, but not directly behind single door controller.
For best reading distance, offset the single door controller and
auxiliary reader by about 50 cm above and 12 m below
(suggestion value).
3. Normally, AR-721U will read a Card / Key Tag at up to 8 cm.
However, when AR-721U reader is mounted directly on a metal
surface, the reading distance decreases slightly. To reduce this
effect, install wood or plastic between the mounting surface and
mounting plate, this will restore most of the reading distance.

6
2.3 Wiring
Table 1 - Color Coding
Wire Application Wire Color Description
1 Red DC Power 12V
Power
2 Black DC Power 0V
3 Yellow LED Red Input ( Low Bright)
LED
4 Brown LED Green Input ( Low Bright)
5 Blue Wiegand DAT:1
Wiegand
6 Green Wiegand DAT:0
Beeper 7 Purple Beeper Input ( Low Sound )
8 White Card Present
Beeper 9 Gray Beeper Output
Output Selection
Output WG26 WG34 RS-232 Magnetic ( ABA )
34/26 Open Close Open Close
ABA Open Open Close Close

7
AR-721U RS-232 Format: ( 9600,N, 8, 1 SOYAL Format )
DAT:0: TTL Inverted Serial Output.
( Can connect to PC comm port )
DAT:1: TTL Serial Output.
( connect to PC comm. port through RS-232 invert driver )

2.4 PCB board
2.4.1 No waterproof
ABA 34126
Buzzer
721U PCB
Output Format
WG 26
WG 34
ABAII
RS-232
ABA 34126
34126ABA
34126ABA
34126ABA
(Default)
2.4.2 Waterproof
Output Format
AR-721U
Buzzer
Cut for WG26 bit
Connect for WG34 bit (Default)
8

2.5 Installation diagram
2.5.1 AR-721U & AR-721H
BA
CN4
CN2
P2
7AC2
Red
CN2
1
DAT:11Blue Blue
AR-721U
Color
Pin
AFunction
Pin
B
Green
Pink
Brown
Yellow
5
3
2
4
DAT:0
Beeper input
Red LED
Green LED
Purple
Green
Brown
Yellow
-GND
+12VDC
SOYAL
12VDC 500mA
Power Supply
RELAY
CN1
P1
CN1
Black
Red
721H5DS
The installation of 721H and auxiliary reader 721U
CN3
Black
9

2.5.2 AR-721U & AR-727H
Green
Blue
Yellow
Purple
Brown
The installation of 727H and auxiliary readers
721U
12VDC 2A
Power Supply
Red(+12VDC)
Black
Red 1
721K
Red
Black
CN1
1
~
Yellow
Brown
CN2 Green
Pink
Blue
661U
Black(-GND)
Brown
Yellow
Green
Pink
Blue
727H
CN3
CN1
10

2.5.3 AR-721U & AR-821EF
CN2
P2
A
Red(+12VDC)
Black(-GND)
Red(+12VDC)
Black(-GND)
1
B
TP1
821EF
Red LED
Yellow
7Yellow
CN7
Black(-GND)
P1
CN1
CN3 CN2
Red(+12VDC)
3
Pin
A
5
4
6
Blue Blue
Color BPin
Pink
Green
Brown Purple
Green
Brown
CN1
+3V
DAT:1
Function
DAT:0
Beeper Input
Green LED
~
reader 721U
Power Supply
12VDC 2A
The installation of 821EF and auxiliary
11

2.5.4 AR-721U & AR-829E
Yellow
Purple
Brown
Blue
Green
The installation of 829E and auxiliary readers
721U
12VDC 2A
Power Supply
Red(+12VDC)
Black
Red 1
721K
Red
Black
CN1
1
~
Yellow
Brown
CN2 Green
Pink
Blue
661U
Black(-GND)
Brown
Yellow
Green
Pink
Blue
829E
CN1
CN2
12

13
3
. AR-721K Installation
3.1 Steps
1. Use the screwdriver to screw the mounting plate on the wall.
2. Pull cable ends through the access hole in the mounting plate.
AR-721K must be connected before power is applied to the
single door controller.
3. Connect plug P1 to socket CN1 on the AR-721K circuit board.
Connect plug P2 to socket CN2 on the AR-721K circuit board.
Connect plug P3 to socket CN3 on the AR-721K circuit board.
4. Attach the AR-721K to the mounting plate and install screw
(supplied) into the hole at the bottom with the Allen wrench
(supplied).
5. Apply power. The red LED will flash once and the beeper will
sound. Refer to beginning of this manual for programming.

14
3.2 Installation Notice
1. Single door controller locate inside the secure area for use as an
exit controller, the auxiliary reader locate exterior wall for use as
an entrance reader, but not directly behind single door controller.
For best reading distance, offset the single door controller and
auxiliary reader by about 50 cm above and 12 m below
(suggestion value).
2. Normally, single door controller will read a Card / Key Tag at up
to 15 cm. However, when single door controller or optional
auxiliary reader is mounted directly on a metal surface, the
reading distance decreases slightly. To reduce this effect, install
wood or plastic between the mounting surface and mounting
plate, this will restore most of the reading distance.
3. AR-721K can cover standard electrical boxes.

15
3.3 Wiring
Table 1 - Connector P1 Color Coding
Wire Application Wire Color Description
1 Thick Red DC Power 12V
Power
2 Thick Black DC Power 0V
Table 2 - Connector P2 Color Coding (Wiegand Read Head )
Wire Application Wire Color Description
1 Thin Blue Wiegand DAT:1 Input
ABA Format:Clock
2 Thin Green Wiegand DAT:0 Input
ABA Format:Data
Wiegand
ABA
3 Orange ABA Format Card Present
4 No Connection
Beeper 5 Pink Beeper Input ( Low Sound )
6 Brown
LED Green Input ( Low Bright)
LED
7 Yellow LED Red Input ( Low Bright)

Table 3 - Connector P3 Color Coding (Tamper Switch )
Wire Application Wire Color Description
1 Red N.C.
2 Orange COM
Tamper Switch
3 Yellow N.O.
3.4 PCB board
EM Format
SOYAL Format
BIT(26/34)
ABA 10
WG 34
Output Format
J2
WG J1 J3
Buzzer
1FF9
721K WG 34
WG 26
J3
J3
J2
J2
WG
WG
BIT(26/34)
BIT(26/34)
(Default)
(Default)
J2
J2
WG
WG
BIT(26/34)
BIT(26/34)
16

3.5 Installation diagram
3.5.1AR-721K & AR-721H
CN1
CN1
P 1
Gray
Black
Red
-GND
+12VDC
+12VDC
-GND
12VDC 2A
Power Supply
1
12VDC 500mA
Power Supply
7AC2
CN4CN2
721K
CN3
SOYAL
-GND
+12VDC
CN1
P 1
CN1
P 2
CN2
Black
Red
Blue White (N.O)
White (COM)
CN4CN2
721H5DS
7AC2
+12VDC
CN3
COM
N.O
ALM
N.C
SOYAL
+12VDC
-GND
RELAY
Yellow(LED)
Brown(LED)
Green(DAT:0)
Blue(DAT:1)
Pink (ALM)
The installation of 721H and auxiliary reader 721K
P 2
~
CN2
17

3.5.2AR-721K & AR-727H
Green
Blue
Yellow
Purple
Brown
The installation of 727H and auxiliary readers
721U
12VDC 2A
Power Supply
Red(+12VDC)
Black
Red 1
721K
Red
Black
CN1
1
~
Yellow
Brown
CN2 Green
Pink
Blue
661U
Black(-GND)
Brown
Yellow
Green
Pink
Blue
727H
CN3
CN1
18

3.5.3AR-721K & AR-821EF
Black(-GND)
Red(+12VDC)
CN1
P1
CN2
P2
A
Black(-GND)
Red(+12VDC)
P2
CN2
~
821EF
1
~
CN2 CN4
B27BF
721K
1
+3V
DAT:024 Green
3
CN1
CN3
CN7
CN2
Color
Blue Pin
1
BFunction
DAT:1
6
5
7
Beeper Input
Green LED
Brown
Pink
Yellow 6
5
7Red LED
CN3
The installation of 821EF and auxiliary
TP1
APin
Red(+12VDC)
reader 721K
Black(-GND)
Power Supply
12VDC 2A
CN1
CN1
P1
SOYAL
19
Other manuals for AR-721U
2
This manual suits for next models
2
Table of contents
Other Soyal Controllers manuals

Soyal
Soyal AR-716Ei User manual

Soyal
Soyal AR-716EV2 User manual

Soyal
Soyal AR-821EF User manual

Soyal
Soyal AR-721U User manual

Soyal
Soyal AR-721E User manual

Soyal
Soyal AR-716E User manual

Soyal
Soyal AR-888H User manual

Soyal
Soyal AR-401 User manual

Soyal
Soyal AR716-E02 User manual

Soyal
Soyal AR-727HB-RAY Series Installation guide