Sper scientific 840011 User manual

Pocket Laser
PowerMeter
840011
Instruction Manual
WARRANTY
Sper Scientic warrants this product against defects
in materials and workmanship for a period of ve
(5) years from the date of purchase, and agrees to
repair or replace any defective unit without charge.
If your model has since been discontinued, an
equivalent Sper Scientic product will be substituted
if available. This warranty does not cover probes,
batteries, battery leakage, or damage resulting
from accident, tampering, misuse, or abuse of the
product. Opening the meter to expose its electronics
will void the warranty.
To obtain warranty service, ship
the unit postage prepaid to:
SPER SCIENTIFIC LTD.
8281 E. Evans Rd., Suite 103
Scottsdale, AZ 85260
The defective unit must be accompanied by a
description of the problem and your return address.
INTRODUCTION
This tiny meter is less than ¾” thick,
weighing only 4 oz. (120 g) and is easily
carried in a shirt pocket.
The controls, display and sensor are all
neatly contained and protected within the
folding case with directions printed right
inside the cover.
This meter features a bar graph display,
auto power o󰀨, hold functions and indicates
low battery and over range.
SPECIFICATIONS CONSIDERATIONS
• Clean the sensor with a soft dry cloth.
• Turn the selector to OFF after use.
• To protect the sensor, store the unit with the cover closed.
• Do not expose the unit to excess direct sunlight, shock, vibration, humidity, or
extreme temperatures.
• Fluctuations in the reading may be due to shadows or changes in the line
voltage. Do not move the probe’s cord during measurement.
• Avoid Range Overload.
• Opening the case, except for replacing the batteries, will void the warranty
• Laser light can be harmful to the eyes and skin, avoid exposure to the beam and
do not look directly into the light source.
• Do not aim the light source at the eyes of other humans or animals.
• Do not aim the light source into a mirror or reective surface where the light
could be reected back into your eyes.
Insert the fresh batteries (match the
polarity) and replace the cover.
Remove the batteries when the
instrument will not be used for a
prolonged period.
Note...
This instrument uses 633 nm of a He-
Ne laser as the reference wavelength
To measure light wavelengths other
than 633 nm, convert the reading
using the sensitivity correction
coe󰀩cient obtained from the
photodiode’s spectral sensitivity
characteristics (typical values).
Min/Max (hold): Press the Case Lock
button to cycle through minimum hold (“DH”
and “MIN” is displayed), maximum hold
(“DH” and “MAX” is displayed), and normal
mode. Min/Max is cancelled when the range
is changed.
Automatic Shut O󰀨: The instrument has an
automatic shut o󰀨 function in order to prolong
battery life. After approximately 30 minutes
without activity, the meter will automatically
shut o󰀨. When this occurs, turn the range
selector to OFF for about 2 seconds before
selecting a measurement range.
Battery Replacement:
Replace the batteries
when “BT” appears in the
display. Remove the battery
compartment cover using
a screwdriver.
Measurement of weak laser power
(below 1 mW) tends to be a󰀨ected by
ambient light. In such cases, perform
the measurement in a darkened room.
The probe can be snapped
into a xed position during the
measurement, as shown.
After measuring the current
power, set the Power/Range
Selector to the optimum range.
Turn the selector to OFF when the
measurement is complete.
Store the probe so
the sensor faces up.
Take care not pinch
the probe’s wire in
the unit’s cover.
PANEL DESCRIPTION MEASUREMENT PROCEDURES
Open the cover by
pressing and holding
the Case Lock button.
Turn the selector to the
maximum (40 mW) measurement range.
If the measurement is over range, “4000”
displays and the “4” blinks.
Hold the probe’s sensor at a right angle
to the source to be measured. With
some lasers the power may vary due
to “return light” from the light sensor
surface. In such cases, change the
angle of the sensor so that the reect-
ed light does not return directly into the
laser light output.
Case
Lock
Button
Sensor Probe
Probe Storage
Protective
Cover
LCD
Power/Range
Selector
Example: When the measured laser light wavelength is
780 nm and the power meter reading is 2.44 mW:
Reading Correction coe󰀩cient wavelength converted
value 2.44 (mW) x 0.73 ═ 1.78 (mW)

Other Sper scientific Measuring Instrument manuals

Sper scientific 300056 User manual

Sper scientific

Sper scientific 300056 User manual

Sper scientific 850011 User manual

Sper scientific

Sper scientific 850011 User manual

Sper scientific 850001 User manual

Sper scientific

Sper scientific 850001 User manual

Sper scientific 800058 User manual

Sper scientific

Sper scientific 800058 User manual

Sper scientific 840029 User manual

Sper scientific

Sper scientific 840029 User manual

Sper scientific 860040 Guide

Sper scientific

Sper scientific 860040 Guide

Sper scientific 800020 User manual

Sper scientific

Sper scientific 800020 User manual

Sper scientific 840021 User manual

Sper scientific

Sper scientific 840021 User manual

Sper scientific AquaShock 850034K User manual

Sper scientific

Sper scientific AquaShock 850034K User manual

Sper scientific AquaShock 850046K User manual

Sper scientific

Sper scientific AquaShock 850046K User manual

Sper scientific 840029 User manual

Sper scientific

Sper scientific 840029 User manual

Sper scientific 850009 User manual

Sper scientific

Sper scientific 850009 User manual

Sper scientific 850007 User manual

Sper scientific

Sper scientific 850007 User manual

Sper scientific 800015 User manual

Sper scientific

Sper scientific 800015 User manual

Sper scientific 300058 User manual

Sper scientific

Sper scientific 300058 User manual

Sper scientific 900019 User manual

Sper scientific

Sper scientific 900019 User manual

Sper scientific 300079 User manual

Sper scientific

Sper scientific 300079 User manual

Sper scientific 800015 User manual

Sper scientific

Sper scientific 800015 User manual

Sper scientific 300003 User manual

Sper scientific

Sper scientific 300003 User manual

Sper scientific 850013 User manual

Sper scientific

Sper scientific 850013 User manual

Sper scientific 300107 User manual

Sper scientific

Sper scientific 300107 User manual

Sper scientific 840005 User manual

Sper scientific

Sper scientific 840005 User manual

Sper scientific AquaShock Bluetooth pH Kit 850057K User manual

Sper scientific

Sper scientific AquaShock Bluetooth pH Kit 850057K User manual

Sper scientific 850069 User manual

Sper scientific

Sper scientific 850069 User manual

Popular Measuring Instrument manuals by other brands

RX only stryker user guide

RX only

RX only stryker user guide

Pro's Kit MT-3102 user manual

Pro's Kit

Pro's Kit MT-3102 user manual

dymax Accu-Cal 50 user guide

dymax

dymax Accu-Cal 50 user guide

Sacher Lasertechnik TEC-500 Technical documentation

Sacher Lasertechnik

Sacher Lasertechnik TEC-500 Technical documentation

Novasina PascalMaxx +/-50Z operating instructions

Novasina

Novasina PascalMaxx +/-50Z operating instructions

AEMC 193-24-BK user manual

AEMC

AEMC 193-24-BK user manual

Minolta FLASH METER IV - PART 2 manual

Minolta

Minolta FLASH METER IV - PART 2 manual

PCB Piezotronics CS625B11 Installation and operating manual

PCB Piezotronics

PCB Piezotronics CS625B11 Installation and operating manual

Hoymiles HMS-1600-4T Quick installation guide

Hoymiles

Hoymiles HMS-1600-4T Quick installation guide

Lovato DME D122MID installation manual

Lovato

Lovato DME D122MID installation manual

Fluke PRUFTECHNIK VIB 6.172 Additional Instructions for Installation and Operation

Fluke

Fluke PRUFTECHNIK VIB 6.172 Additional Instructions for Installation and Operation

Nikon Forestry Pro II user manual

Nikon

Nikon Forestry Pro II user manual

sauter CP P1 instruction manual

sauter

sauter CP P1 instruction manual

Eaton Power Xpert Meter 2000 quick start guide

Eaton

Eaton Power Xpert Meter 2000 quick start guide

MRC PMG-302 Operation manual

MRC

MRC PMG-302 Operation manual

WEBTEC FlowHUB Series user manual

WEBTEC

WEBTEC FlowHUB Series user manual

ALTHEN NM1-ISU-IP-3L-24 Series manual

ALTHEN

ALTHEN NM1-ISU-IP-3L-24 Series manual

National Instruments 9775 Getting started guide

National Instruments

National Instruments 9775 Getting started guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.