Operating instructions
Additional languages www.r-stahl.com
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60

General information
2
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
Contents
1 General information ............................................................................................2
1.1 Manufacturer .......................................................................................................2
1.2 Information regarding the operating instructions .................................................3
1.3 Further documents ..............................................................................................3
1.4 Conformity with standards and regulations .........................................................3
2 Explanation of the symbols .................................................................................3
2.1 Symbols in these operating instructions .............................................................3
2.2 Warning notes .....................................................................................................4
2.3 Symbols on the device ........................................................................................5
3 Safety notes ........................................................................................................5
3.1 Operating instructions storage ............................................................................5
3.2 Safe use ..............................................................................................................5
3.3 Modifications and alterations ..............................................................................5
4 Function and device design ................................................................................6
4.1 Function ..............................................................................................................6
5 Technical data .....................................................................................................7
6 Transport and storage .........................................................................................9
7 Mounting and installation ..................................................................................10
7.1 Dimensions / fastening dimensions ..................................................................10
7.2 Mounting / dismounting, operating position ......................................................11
7.3 Installation .........................................................................................................21
8 Commissioning .................................................................................................21
9 Operation ..........................................................................................................22
9.1 Troubleshooting ................................................................................................22
10 Maintenance, overhaul, repair ..........................................................................22
10.1 Maintenance .....................................................................................................23
10.2 Repair ...............................................................................................................23
10.3 Returning the device .........................................................................................24
11 Cleaning ............................................................................................................24
12 Disposal ............................................................................................................24
13 Accessories and spare parts ............................................................................24
1 General information
1.1 Manufacturer
R. STAHL Schaltgeräte GmbH
Business Unit Lighting & Signalling
Nordstr. 10
99427 Weimar
Germany
R. STAHL Schaltgeräte GmbH
Am Bahnhof 30
74638 Waldenburg
Germany
Phone:
Fax:
Internet:
E-mail:
+49 3643 4324
+49 3643 4221-76
www.r-stahl.com
Phone:
Fax:
Internet:
E-mail:
+49 7942 943-0
+49 7942 943-4333
www.r-stahl.com

222936 / YL6060300020
2018-04-13·BA00·III·en·01
Explanation of the symbols
3
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
1.2 Information regarding the operating instructions
ID-No.: 222936 / YL6060300020
Publication Code: 2018-04-13·BA00·III·en·01
The original instructions are the English edition.
They are legally binding in all legal affairs.
1.3 Further documents
• Data sheet
For documents in additional languages, see www.r-stahl.com.
1.4 Conformity with standards and regulations
See certificates and EU Declaration of Conformity: www.r-stahl.com.
The device has IECEx approval. For certificate please refer to the IECEx homepage:
http://iecex.iec.ch/
2 Explanation of the symbols
2.1 Symbols in these operating instructions
Symbol Meaning
Tips and recommendations on the use of the device
General danger
Danger due to explosive atmosphere
Danger due to energised parts

Explanation of the symbols
4222936 / YL6060300020
2018-04-13·BA00·III·en·01
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
2.2 Warning notes
Warnings must be observed under all circumstances, in order to minimize the risk due to
construction and operation. The warning notes have the following structure:
• Signalling word: DANGER, WARNING, CAUTION, NOTICE
• Type and source of danger/damage
• Consequences of danger
• Taking countermeasures to avoid the danger or damage
= Strobe
= Sounder
= Earth
= Sounder Tone
= Telephone initiate
DANGER
Danger to persons
Non-compliance with the instruction results in severe or fatal injuries to
persons.
WARNING
Danger to persons
Non-compliance with the instruction can result in severe or fatal injuries to
persons.
CAUTION
Danger to persons
Non-compliance with the instruction can result in light injuries to persons.
NOTICE
Avoiding material damage
Non-compliance with the instruction can result in material damage to the device and / or
its environment.

222936 / YL6060300020
2018-04-13·BA00·III·en·01
Safety notes
5
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
2.3 Symbols on the device
3 Safety notes
3.1 Operating instructions storage
• Read the operating instructions carefully and store them at the mounting location of
the device.
• Observe applicable documents and operating instructions of the devices to be
connected.
3.2 Safe use
• Read and observe the safety notes in these operating instructions!
• Observe characteristic values and rated operating conditions on the rating and
data plates!
• Observe additional information plates on the device!
• Use the device in accordance with its intended and approved purpose only!
• We cannot be held liable for damage caused by incorrect or unauthorized use or
by non-compliance with these operating instructions.
• Before installation and commissioning, make sure that the device is not damaged!
• Work on the device (installation, maintenance, overhaul, repair) may only be carried
out by appropriately authorized and trained personnel.
3.3 Modifications and alterations
Symbol Meaning
05594E00
CE marking according to the current applicable directive.
02198E00
According to marking, device certified for hazardous areas.
15649E00
Input
15648E00
Output
DANGER
Explosion hazard due to modifications and alterations to the device!
Non-compliance results in severe or fatal injuries.
• Do not modify or alter the device.
No liability or warranty for damage resulting from modifications and
alterations.

Function and device design
6222936 / YL6060300020
2018-04-13·BA00·III·en·01
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
4 Function and device design
4.1 Function
The explosion proof combination signal series YL60 is an audible and visual signal.
It provides an audible and/or visual signal intended to alert, warn or draw attention to an
event. It is designed for use in hazardous or harsh environments. In hazardous areas the
devices have explosion protection for ATEX / IECEx Zones 1 & 2 for gas and 21 & 22 for
dust. Gas groups covered are IIB & IIB + H2, dust protection for IIIC.
UL certified variants offer protection to Class I Division I Gas groups BCD,
Class II Division I Gas groups EFG.
The device is not intended for continuos use.
The life of the xenon flash tube is guaranteed for the following number of flashes:
DANGER
Explosion hazard due to improper use!
Non-compliance results in severe or fatal injuries.
• Use the device only according to the operating conditions described in
these operating instructions.
Variant Number of flashes
5 J 2 million

222936 / YL6060300020
2018-04-13·BA00·III·en·01
Technical data
7
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
5 Technical data
Explosion Protection
Global (IECEx)
Gas and dust
Europe (ATEX)
Gas and dust
North America (cULus listed)
Gas and dust
IIB+H2 IECEx BAS 05.0087X
IIB IECEx BAS 05.0086X
IIB+H2, IIB IEC 60079-0: 2011 / IEC 60079-1: 2007-04 / IEC 60079-31: 2008
IIB+H2 Ex d IIB+H2 T4 Gb (Ta = -20 … +60°C)
Ex tb IIIC T135°C Db IP 66 (Ta = -20 … +60 °C)
Ex d IIB+H2 T6 Gb (Ta = -20 … +40 °C)
Ex tb IIIC T85°C Db IP 66 (Ta = -20 … +40 °C)
IIB Ex d IIB T4 Gb (Ta = -35 … +60 °C)
Ex tb IIIC T135°C Db IP 66 (Ta = -35 … +60 °C)
Ex d IIB T6 Gb (Ta = -35 … +40 °C)
Ex tb IIIC T85°C Db IP 66 (Ta = -35 … +40 °C)
IIB+H2 Baseefa02ATEX0222X
IIB Baseefa02ATEX0212X
IIB+H2, IIB EN 60079-0: 2009 / EN 60079-1: 2007 / EN 60079-31: 2009
IIB+H2 EII 2 G Ex d IIB+H2 T4 Gb (Ta = -20 … +60 °C)
EII 2 D Ex tb IIIC T135°C Db IP 66 (Ta = -20 … +60 °C)
EII 2 G Ex d IIB+H2 T6 Gb (Ta = -20 … +40 °C)
EII 2 D Ex tb IIIC T85°C Db IP 66 (Ta = -20 … +40 °C)
IIB EII 2 G Ex d IIB T4 Gb (Ta = -35 … +60 °C)
EII 2 D Ex tb IIIC T135°C Db IP 66 (Ta = -35 … +60 °C)
EII 2 G Ex d IIB T6 Gb (Ta = -35 … +40 °C)
EII 2 D Ex tb IIIC T85°C Db IP 66 (Ta = -35 … +40 °C)
IIB+H2, IIB E161818, E188831
IIB+H2, IIB SL: UL 60079-0 / UL 60079-1 / UL 1203 / UL 1638
CSA C22.2 No. 30-M1986 / CSA C22.2 No. 25-M1966 /
CSA E60079-0-7 / CSA E60079-1
IIB+H2 CLASS I, DIVISION 1, GROUPS B, C and D, T4;
CLASS II, DIVISION 1, GROUPS E, F and G;
CLASS III
CLASS 1, ZONE 1 AEx d IIB+H2 T4
CLASS 1, ZONE 1 Ex d IIB+H2 T4
Operating temperature -25 ... +66 °C
Audible signal appliance public mode with supplementary
Visual signal appliance private mode
IIB CLASS I, DIVISION 1, GROUPS C and D, T4;
CLASS II, DIVISION 1, GROUPS E, F and G;
CLASS III
CLASS 1, ZONE 1 AEx d IIB T4
CLASS 1, ZONE 1 Ex d IIB T4
Operating temperature -35 ... +66 ºC
Audible signal appliance public mode with supplementary
Visual signal appliance private mode

Technical data
8222936 / YL6060300020
2018-04-13·BA00·III·en·01
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Kazakhstan (TR),
Russia (TR), Taiwan (ITRI), USA & Canada (cULus),
Belarus (TR)
Technical Data
Technical data
Product weight 6 kg
Electrical data
Rated operational
voltage
24 V DC, 48 V DC, 115 V AC and 230 V AC operational parameters + or -10 %
Rated operational
current
Mechanical data
Material
Enclosure aluminium, seawater resistant
Horn ABS, flame retardant
Lens cover polycarbonate
Fixings stainless steel
Cable entries 2 cable entries, equipped with stopping plug (1x) and dust cap (1x)
UL devices: equipped with M20 / 1/2 ’’ adapters (2x)
Degree of protection IP66 – IEC 60529
NEMA 4X – UL 50
Operating temperature range
Variant dependant see Explosion protection
Explosion Protection
24 V DC 570 mA
48 V DC 435 mA
115 V AC 200 mA
230 V AC 100 mA

222936 / YL6060300020
2018-04-13·BA00·III·en·01
Transport and storage
9
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
For further technical data, see www.r-stahl.com.
6 Transport and storage
• Transport and store the device only in the original packaging.
• Store the device in a dry place (no condensation) and vibration-free.
• Do not drop the device.
Acoustic data
Volume 110 dB(A) / 1 m
Polar diagram
Luminous characteristics
Effective candela
Candela seconds
Flash energy 5 J
Flash rate 60 FPM
Technical Data
Horizontal plane Vertical plane
15288E00
5 J
Clear 46 cd
Yellow 42 cd
Amber 28 cd
Red 14 cd
Blue 13 cd
Green 10 cd
Magenta N/A
5 J 9.3 lumens Clear lens

Mounting and installation
10 222936 / YL6060300020
2018-04-13·BA00·III·en·01
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
7 Mounting and installation
7.1 Dimensions / fastening dimensions
Dimensional Drawings (All Dimensions in mm [inches]) – Subject to Alterations
18380E00

222936 / YL6060300020
2018-04-13·BA00·III·en·01
Mounting and installation
11
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
7.2 Mounting / dismounting, operating position
• Mount the device on a flat surface suitable for its weight.
• The tone output should be directed towards the area to be covered
(see chapter Technical Data, Polar diagram).
• Insert the cables using certified and flameproof cable glands which are suitable for the
gas group.
• Close unused entries using certified and flameproof stopping plugs.
7.2.1 Installation conditions for electrical connection
DANGER
Risk of explosion!
Risk of injuries and material damage!
• Terminal sleeves are fitted, they must be gas-tight and applied with a
suitable tool.
DANGER
Explosion hazard!
Risk of injuries and material damage!
• Carefully remove or replace the components.
• Exposed joint surfaces must not be damaged and must be protected
from dust and dirt.
• Install the end flanges squarely without applying any force. Do not use
a hammer or other tools when working on the flanges and do not use the
fixing screws to pull down the flanges.
DANGER
Explosion hazard!
Risk of injuries and material damage!
• Only use cable glands with corresponding certificate. The cable glands
must be flameproof (Ex d) and suitable for the type of cable used.
• Close unused open holes in the enclosure with flameproof stopping
plugs.
• Close unused cable glands using flameproof plugs.
• Cable glands, stopping plugs and plugs must meet the requirements of
IEC/EN 60079-14.
• Installation of the cable gland must be performed in accordance with the
manufacturer's instructions.
• Cable entry temperature may exceed 70 °C.
• To ensure degree of protection IP 66, a non-hardening sealant must be
applied to the threads.
DANGER
Danger due to energised parts!
Non-compliance results in severe or fatal injuries.
• Before opening and dismounting the device, disconnect it from the
power supply.
• Secure the device against unauthorized switching.

Mounting and installation
12 222936 / YL6060300020
2018-04-13·BA00·III·en·01
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
7.2.2 Access to the PCB
• Remove the 3 screwST 4,2 x 13
• Lift horn cover
• Remove the 4 cheese-head screws M5 x 16
• Lift sounder flange
• Disconnect pressure unit from PCB (see Electrical Connection, Key Components)
• Lift PCB to expose terminals for connection
(see Electrical Connection, Wiring Diagrams for details)
15256E00
1 Screws ST 4,2 x 13
2 Horn cover
3 Cheese-head screws M5 x 16
4 Sounder flange
5PCB
6Enclosure
1
2
3
4
5
6

222936 / YL6060300020
2018-04-13·BA00·III·en·01
Mounting and installation
13
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
7.2.3 Reassembly of enclosure
Inserting the PCB
For correct positioning of the PCB there are 2 grooves in the enclosure.
Depending on the version, insert the PCB in the corresponding groove!
• Carefully insert the connected printed circuit board.
• Connect the horn flange to the printed circuit board.
• Set the horn flange on the enclosure. Do not clamp in any cables in the process.
• Insert the horn flange in a straight position without applying any pressure.
• Replace cheese-head screws M5 x 16 (see information below) and tighten the screws
with a tightening torque of 3 Nm.
• Re-attach the cover. Tighten the ST 4.2 x 13 screws with a tightening torque of 0.4 Nm.
18814E00 18813E00
• YL60/./D50/./..
• YL60/./F50/./..
• YL60/./L50/./..
• YL60/./N50/./..
• Carefully assemble the device to ensure that the degree of protection
is IP 66.
• The cheese-head screws are delivered with Nyltite seals
(see the "Connection" section above).
• Check the Nyltite seals for damage before the installation.
• Tighten cheese-head screws with a torque of 3 Nm.
• Use the Nyltite seal a maximum of five times with the tightening torque.
15748E00

Mounting and installation
14 222936 / YL6060300020
2018-04-13·BA00·III·en·01
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
7.2.4 Electrical connection
Key Components
Cable Connection
15257E00 15258E00
Key components YL60 DC Key components YL60 AC
Legend
7 = Terminal blocks
8 = Connector for sounder
9 = Tone selection switch (ton table)
10 = Link for combined function (DC-version only)
15266E00
Link connected:
• Strobe and sounder work together.
Link removed:
• Strobe and sounder independent
function.
= Strobe
= Sounder
• Approximately 20 cm (8 Inch) tails are required inside the enclosure
for connection to the terminals on the PCB. This is especially important
for installation using solid core cable.
• The terminals accept wires of 2.5 mm2 or 14 to 18 AWG.
7
8
910
7
8
9
0V
+V
LK1
LK2

222936 / YL6060300020
2018-04-13·BA00·III·en·01
Mounting and installation
15
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
Interconnection of devices parallel
Up to 10 devices with common supplies may be connected as a single system loop.
Circuit diagrams
DC version
Combined function of sounder and strobe with one signal tone
Connection to a 2-wire conductor
Combined function of sounder and strobe with two signal tones
Connection to a 3-wire conductor
Line monitoring for devices with DC
• Through reverse polarity
• By connecting an EOL resistor between 0 V and +V.
The resistance value is defined by the system developer.
Two signal levels for devices with DC
• Through reverse polarity
• By connecting a third electrical line.
Two signal levels for devices with AC
• By connecting a third electrical line.
18400E00
Tone 1 Tone 2
18400E00 18402E00

Mounting and installation
16 222936 / YL6060300020
2018-04-13·BA00·III·en·01
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
Connection to a 2-wire conductor - second tone by reverse polarity
Independent function of sounder and strobe
Connection to a 4-wire conductor
Combined function of sounder and strobe - activation by telephone signal
Sounder and strobe are activated by a telephone signal. The function is retained as
long as the telephone signal is available. The strobe can flash up to four times after
deactivating the telephone signal.
Tone 1 Tone 2
18403E00 18404E00
15266E00
Remove jumper from LK1 and LK2
18401E00
Connection:
• Strobe TB1
• Sounder TB2
Second tone by reverse polarity or
3-wire connection to TB2, as shown
above in connection diagrams.
18414E00
0V
+V
LK1
LK2

222936 / YL6060300020
2018-04-13·BA00·III·en·01
Mounting and installation
17
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
AC version
Combined function of sounder and strobe with one signal tone
Connection to a 2-wire conductor
Combined function of sounder and strobe with two signal tones
Connection to a 3-wire conductor
Independent function of sounder and strobe
Connection to a 3-wire conductor
18414E00
Bridge TB1 and TB2 using a conductor.
Tone 1 Tone 2
18408E00 18407E00
18406E00
Second tone via connection to TB4
possible (see above).

Mounting and installation
18 222936 / YL6060300020
2018-04-13·BA00·III·en·01
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
Combined function of sounder and strobe - activation by telephone signal
Sounder and strobe are activated by a telephone signal. The function is retained as
long as the telephone signal is available. The strobe can flash up to four times after
deactivating the telephone signal.
7.2.5 Earth connection
• The unit must be connected to a good quality earth.
• The internal Earth connection is the primary point. The external connection is for a
supplementary bonding connection and is used where local code or authorities permit
or require such connection.
18409E00
= Strobe
= Sounder
= Earth
= Sounder Tone
= Telephone initiate
15265E00

222936 / YL6060300020
2018-04-13·BA00·III·en·01
Mounting and installation
19
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
7.2.6 Sound tone selection
• For signal tone selection and its switch positions refer to the table below.
• Check if the correct switch positions of the selected signal tones have been selected.
Tone table
Tone
no.
Version Frequency
Sound
selection
switch
12345
(ON = 1)
Repeti-
tion rate
(sec)
Special application
Tone
01
Alternate two-tone 800-1000 11111 0.5 Fire alarms -
Level crossing
Tone
02
Alternate two-tone 2500-3100 01111 0.5 Security alarms
Tone
03
Alternate fast two-tone 800-1000 10111 0.25 Increased urgency -
Level crossing
Tone
04
Alternate fast two-tone 2500-3100 00111 0.25 Security deterrent
Tone
05
Alternate two-tone 440-554 11011 0.4/0.1 AFNOR, France
Tone
06
Alternate two-tone 430-470 01011 1.0
Tone
07
Alternate very fast
two-tone
800-1000 10011 0.13
Tone
08
Alternate very fast
two-tone
2500-3200 00011 0.07
Tone
09
Alternate two-tone 440-554 11101 2.0 Turn out, Sweden
(SS 031711)
Tone
10
Continuous tone 700 01101 All clear, Sweden
(SS 031711)
Tone
11
Continuous tone 1000 10101
Tone
12
Continuous tone 1000 00101
Tone
13
Continuous tone 2300 11001
Tone
14
Continuous tone 440 01001
Tone
15
Interrupted tone 1000 10001 2.0
Tone
16
Interrupted tone 420 00001 1.25 AS2220, Australia
Tone
17
Interrupted tone 1000 11110 0.5
Tone
18
Interrupted tone 2500 01110 0.25
Tone
19
Interrupted tone 2500 10110 0.5

Mounting and installation
20 222936 / YL6060300020
2018-04-13·BA00·III·en·01
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
The PFEER sound signals recommended by UKOOA are:
Sound selection switch detail
Tone
20
Interrupted tone 700 00110 6/12 Important message, Sweden
Tone
21
Interrupted tone 1000 11010 1.0
Tone
22
Interrupted tone 700 01010 4.0 Air-raid alarm, Sweden
Tone
23
Interrupted tone 700 10010 0.25 Local warning, Sweden
Tone
24
Interrupted tone 720 00010 0.7/0.3 Industrial alarm, Germany
Tone
25
Interrupted, fast,
rising volume
1400 11100 0.25
Tone
26
Fast siren 250-1200 01100 0.085
Tone
27
Rising constantly,
falling
1000 10100 10/40/10 Industrial alarm, Germany
Tone
28
ISO 8201 Evacuation 800-1000 00100 As
standard
International evacuation
alarm
Tone
29
Fast whoop 500-1000 11000 0.15
Tone
30
Slow whoop 500-1200 01000 4.5 Evacuation,
The Netherlands
Tone
31
Reverse sweep 1200-500 10000 1.0 Fire alarm, Germany
(DIN 33404)
Tone
32
Siren 500-1200 00000 3.0
General alarm Sound signal 15 Interrupted tone 1000 Hz
PAPA Sound signal 31 Reverse sweep 1200-500 Hz
Toxic gas Sound signal 11 Continuous tone 1000 Hz
15268E00 15269E00
Standard Telephone initiate
Tone table
SW1
ON = 1
12345
ON
1
SW2
12345
ON
2
SW1
ON = 1
12345
ON
1
Other manuals for YL60 Series
1
Table of contents
Other Stahl Security Sensor manuals
Popular Security Sensor manuals by other brands

Tevel
Tevel CANARY user manual

Ultra-safe
Ultra-safe 96602NS User instruction manual

STEINEL PROFESSIONAL
STEINEL PROFESSIONAL IS 2180-2 installation instructions

Industrial Dynamics
Industrial Dynamics Filtec FT-50 Installation and setup guide

TPI
TPI 721 instruction manual

Mier
Mier Drive-Alert DA-700 instruction manual