Stahl 8118 Series User manual

Operating Instructions
Terminal box
> 8118

Contents
28118609300
S-BA-8118-02-en-15/06/2007
Terminal box
8118
1 Contents
1 Contents ................................................................................................................2
2 General Information ...............................................................................................2
3 Safety instructions .................................................................................................3
4 Conformity to standards ........................................................................................3
5 Function .................................................................................................................3
6 Technical Data ......................................................................................................4
7 Fitting .....................................................................................................................6
8 Installation .............................................................................................................6
9 Commissioning ......................................................................................................6
10 Repairs and Maintenance .....................................................................................7
11 Accessories and spare parts .................................................................................7
12 Disposal .................................................................................................................7
13 Type examination certificate (Page 1) ...................................................................8
14 Declaration of conformity .......................................................................................9
2 General Information
2.1 Manufacturer
R. STAHL Schaltgeräte GmbH
Am Bahnhof 30
D-74638 Waldenburg
Telephone: +49 7942 943-0
Fax: +49 7942 943-4333
Internet: www.stahl.de
2.2 Information about the Operating Instructions
ID NO.: 8118609300
Publication Code: S-BA-8118-02-en-15/06/2007
We reserve the right to make technical changes without notice.
2.3 Purpose of these instructions
Working in hazardous areas, the safety of personnel and plant depends on complying
with all relevant safety regulations.
Assembly and maintenance staff working on installations therefore have a particular
responsibility. They require precise knowledge of the applicable standards and
regulations.
This introduction gives a brief summary of the most important safety measures.
It supplements the corresponding regulations which the staff responsible must study.

8118609300
S-BA-8118-02-en-15/06/2007
Safety instructions
3
Terminal box
8118
3 Safety instructions
Use the device only for its intended purpose.
Incorrect or impermissible use or non-compliance with these instructions invalidates our
warranty provision.
Any alterations and modifications to the device impairing its explosion protection are not
permitted.
Fit and operate the terminal box only if it is clean and undamaged.
Observe the following during installation and operation:
XNational safety regulations
XNational accident prevention regulations
XNational installation regulations
XGenerally recognized technical regulations
XSafety guidelines in these operating instructions
XCharacteristic values and rated operating conditions on the rating and data plates
XAdditional instruction plates fixed directly to the device
Any damage can invalidate the Ex-protection.
4 Conformity to standards
Each device complies with the following standards and regulations:
XDirective 94/9/EC
XEMC Directive No.: 89/336/EEC
XEN/IEC 60079-0, EN/IEC 60079-7, EN/IEC 60079-11, EN/IEC 60079-18,
EN/IEC 61241-0, EN/IEC 61241-1
Device type 8118 is suitable for use in hazardous areas, zones 1, 2 and zones 21, 22.
5Function
The polyester resin terminal boxes are used for the transfer and distribution of electrical
energy.

Technical Data
48118609300
S-BA-8118-02-en-15/06/2007
Terminal box
8118
6 Technical Data
Fitting in terminal boxes
Maximum number of cables related to conductor cross-section and number of terminals under load for temperature class T6 when
Ta(40 °C or T5 when Ta(55 °C:
Types 8118/112 and 8118/114
Type 8118/..2 8118/..4
Version Terminal box with equipment fuse Terminal box without equipment fuse
Explosion protection
Gas explosion protection
Gas explosion protection
(IECEx) Ex em II T6, T5 or T4
Ex ia/ib IIA, IIB, IIC T6 or T5
Dust explosion protection EII 2 D Ex tD A21 IP 66 T80 °C, T95 °C EII 2 D Ex td A21 IP 66 T80 °C, T95 °C,
T130 °C
Dust explosion protection
(IECEx) Ex tD A21 IP66 T 80 °C, T 95 °C or T 130 °C
Certificates
Gas explosion protection PTB 99 ATEX 3103
Dust explosion protection LCIE 02 ATEX 6240
IECEx certification IECEx PTB 06.0026
Housing Polyester resin, dark grey ~RAL 7012, impact strength > 7 Nm, material self-extinguishing and
flame resistant IEC 92-1, UL 94, ASTM D 635-77
Gaskets Polyurethan, foam
Cover fixing 4 x M 4 cheese head screw, stainless steel
Degree of protection IP 66 / IP 67
Rated voltage max.1100 V AC/DC
with special cable glands max. 550 V AC/DC
with special cable glands
Ambient temperature - 50 °C ... + 55 °C
Rated operating cur-
rent max. number of cables *)for conductor cross-section
1.5 mm22.5 mm24 mm2
3 A 16 **)any any
6 A 16 **)12 **)any
10 A 16 **)12 **)12 **)
16 A 6 **)12 **)12 **)
20 A - 6 **)12 **)
25 A - - 8 **)
Ex e EII 2 G Ex em II T6 / T5 / T4
Ex i EII 2 G Ex ia/ib IIA / IIB / IIC T6 /
T5
Ex e EII 2 G Ex em II T. 1)
1) Fuse (2 A
> 2 A to (5 A
(6,3 A
T6
T5
T4

8118609300
S-BA-8118-02-en-15/06/2007
Technical Data
5
Terminal box
8118
Types 8118/122 and 8118/124
Types 8118/132 and 8118/134
Example (8118/122):
Installing fuses (8118/1.3 and 8118/1.4)
Rated operating cur-
rent max. number of cables *)for conductor cross-section
1.5 mm22.5 mm24 mm26 mm2
3 A 26 **)any any any
6 A 26 **)26 **)any any
10 A 26 **)26 **)22 **)any
16 A 6 **)14 **)22 **)20 **)
20 A - 6 **)22 **)20 **)
25 A - - 8 **)20 **)
35A ---4**
)
Rated operating cur-
rent max. number of cables *)for conductor cross-section
1.5 mm22.5 mm24 mm26 mm210 mm2
3 A 36 **)any any any any
6 A 36 **)36 **)any any any
10 A 26 **)36 **)32 **)any any
16 A 6 **)18 **)32 **)24 **)any
20 A - 6 **)22 **)24 **)20 **)
25 A - - 8 **)24 **)20 **)
35A ---6**
)20 **)
50A ----4**
)
*)Each cable brought in and each internal connecting cable counts as a conductor. Jumpers and earthing conductors are not
counted.
**)When using these table values, account may be taken of the simultaneity factor or load factor to IEC 439. The use of a
mixture of fittings with circuits of different cross-sections is possible by pro rata use of the different table values.
Cross-section Current No. of cables Loading
1.5 mm210 A 10 (of 16) 63 %
2.5 mm216 A 4 (of 12) 33 %
Sum 96 % < 100 %
Fuse-base Temperature class TaMax.
permissible surface
temperature
(2 A T6 40 °C T80 °C
> 2 A ... (4 A T5 55 °C T95 °C
> 4 A ... (5 A T5 40 °C T95 °C
> 5 A ... < 6.3 A T4 55 °C T130 °C

Fitting
68118609300
S-BA-8118-02-en-15/06/2007
Terminal box
8118
7Fitting
Whenexplosion-protected equipment isexposedto the weather, itisadvisableto provide
a protective cover or wall.
8 Installation
Mains connection
XThe conductors must be carefully connected.
XThe conductor insulation must reach to the terminal. The conductor itself must not be
damaged (nicked) when removing the insulation.
XEnsure that the maximum permissible conductor temperatures are not exceeded by
suitable selection of cables and means of running them.
XPlease also refer to the terminal details in the technical data.
Earth connection:
The earth connection must be made in all circumstances.
9 Commissioning
Before commissioning the device, ensure that
Xit has been correctly installed
Xit is not damaged
Xit contains no foreign bodies
Xthe connection area is clean
Xthe connection is correctly made
Xthe cables have been correctly brought in
Xall screws and nuts are fully tightened
Xthe cable glands are securely tightened
Xunused cable glands are sealed with plugs certified to Directive 94/9/EC, and unused
holes are sealed by stopping plugs certified to Directive 94/9/EC.
Dimension drawings (all dimensions in mm) - subject to alterations
04466E00 04467E00 04468E00
04469E00
8118/.1.
Terminal box 8118/.2.
Terminal box 8118/.3.
Terminal box Additional dimensions for
cable entries 8161
Nominal
size L [mm]
min. max.
M 20 25 31
M 25 27 33
M 32 32 39
Pg 11 24 25
Pg 13,5 30 31

8118609300
S-BA-8118-02-en-15/06/2007
Repairs and Maintenance
7
Terminal box
8118
10 Repairs and Maintenance
Repairs and maintenance work on the devices may only be carried out by appropriately
authorized and trained personnel.
Before work commences, the devices must be disconnected from the mains.
The following points must be tested during maintenance:
XClamping screw holding the cables is securely seated
XOperating temperature (by EN/IEC 60079-0)
XCracks in plastic enclosures
XDamage to the gaskets
11 Accessories and spare parts
12 Disposal
WARNING
Observe the relevant national regulations for your country!
WARNING
The device may only be cleaned with a damp cloth!
WARNING
Use only original spare parts as well as original accessories made by R. STAHL
Schaltgeräte GmbH. WARNING
The fuses fitted may only be replaced by fuses with matching characteristics. Any
infringements can change the temperature class of the whole box.
Designation Illustration Description Ordering code Weight
kg
Brass plate with
thread
05735E00
For earth continuity when using metal glands drillings are
drilled to order; – –
8118013550 0,030
8118010550 0,060
8118011550 0,080
8118012550 0,140
Fuse-base
05736E00
Type 8560
see current catalogue – –
WARNING
XObserve the national standard for refuse disposal.
for glands can be fitted into enclosure
size1size2size3
1 x M 20 x 1,5 Side C/D Side C/D Side C/D
1 x M 25 x 1,5
1 x M 32 x 1,5
1 x M 20 x 1,5
Side C/D Side C/D
2 x M 25 x 1,5 Side C/D Side C/D
2 x M 32 x 1,5 Side C/D

Type examination certificate (Page 1)
88118609300
S-BA-8118-02-en-15/06/2007
Terminal box
8118
13 Type examination certificate (Page 1)
UNCERTIFIED TRANSLATION
Physikalisch-Technische Bundesanstalt
Braunschweig and Berlin
Page 1/2
EC-type-examination Certificates without signature and official stamp shall not be valid. The certificates may be circulated
only without alteration. Extracts or alterations are subject to approval by the Physikalisch-Technische Bundesanstalt.
In case of dispute, the German text shall prevail.
Physikalisch-Technische Bundesanstalt Bundesallee 100 D-38116 Braunschweig
(1) EC-TYPE-EXAMINATION CERTIFICATE
(2) Equipment and Protective Systems Intended for Use in
Potentially Explosive Atmospheres - Directive 94/9/EC
(3) EC Type Examination Certificate Number
PTB 99 ATEX 3103
(4) Equipment: Junction and Terminal Boxes Type 8118/...-...
(5) Manufacture
r
: R. Stahl Schaltgeräte GmbH
(6) Address: Bergstraße 2, D-74653 Künzelsau
(7) This equipment and any acceptable variation thereto are specified in the schedule to this
certificate.
(8) The Physikalisch-Technische Bundesanstalt, notified body No. 0102 in accordance with Article
9 of the Council Directive 94/9/EC of 23 March 1994, certifies that this equipment has been
found to comply with the Essential Health and Safety Requirements relating to the design and
construction of equipment and protective systems intended for use in potentially explosive
atmospheres, given in Annex II to the Directive.
The examination and test results are recorded in the confidential report PTB Ex 99-30041.
(9) Compliance with the Essential Health and Safety Requirements has been assured by
compliance with:
EN 50 014:1997 EN 50 019:1994 EN 50 020:1994
(10) If "X" is placed after the certificate number, it indicates that the equipment is subject to special
conditions for safe use specified in the schedule to this certificate.
(11) This EC-type-examination Certificate relates only to the design and construction of the
specified equipment in accordance with Directive 94/9/EC. Further requirements of this
Directive apply to the manufacture and supply of this equipment.
(12) The marking of the equipment shall include the following:
II 2 G EEx e II T6/T5 or EEx ia/ib IIA/IIB/IIC T6/T5
Zertifizierungsstelle Explosionsschutz Braunschweig, 19 April 1999
By order:
signed: U. Engel L.S.
Dr.-Ing. U. Engel
Regierungsdirekto
r

8118609300
S-BA-8118-02-en-15/06/2007
Declaration of conformity
9
Terminal box
8118
14 Declaration of conformity



8118609300
S-BA-8118-02-en-15/06/2007
Other manuals for 8118 Series
4
Table of contents
Other Stahl Touch Terminal manuals