WanderGuard® BLUE Wearable Bracelet User Guide
STANLEY Healthcare
75 Portsmouth Blvd., Suite 220, Portsmouth, NH 03801 Tel: 1-800-380-8883 Web: www.stanleyhealthcare.com
© 2021 STANLEY Healthcare. All Rights Reserved. Published: 2021/10/20. 0980-423-000 Rev F. KB# 11749.
FCC Part 15, sub-part C class B, sub-part B, EN 300-328, EN 300-330, EN 301-489, RSS210 (Canada), Radio
Equipment Directive 2014/53/EU (RED), Radio Equipment Directive S.I.2017/1206 (RED), RoHS 2 Directive
2011/65/EU, RoHS 2 Directive S.I.2012/3032. Safety: CE, UKCA, EN62368/UL62368/IEC62368/UL294
D Description SKU
Band Removal tool WGB-REMOVE-1000
Starter Kit for Wearables WGB-TGSTART-1000
Wearable Specifications
LF Frequency 125 kHz
BLE Frequency 2400-2483.5 MHz
Battery Power 3 VDC
Battery Life WGB-TAG-2000-1Y: 90 Days
WGB-TAG-2000-1Y: 1 Year
WGB-TAG-2000-3Y: 3 Years
Operating
Temperature
32° to 122°F (0° to +50°C)
Humidity 0-95% RH @ 70°F (21°C), non-
condensing
IP Rating IP67
UL294 ACC Accessory, TYPE: S, 17XS
Dimensions 2.0 x 1.1 x 0.51” (50.6 x 28 x
13 mm) without band
Weight 0.92 oz. (26.0 g) with band
The Wearable is intended for indoor use only.
STANLEY Healthcare reserves the right to
change specifications without notice.
FCC
Suppliers Declaration of Conformity
47 CFR § 2.1077 Compliance Information
Unique Identifiers:
WGB-TAG-2000-90D
WGB-TAG-2000-1Y
WGB-TAG-2000-3Y
Responsible Party: Stanley Security
Solutions Inc., STANLEY Healthcare Div.,
4600 Vine Street, Lincoln, NE 68503
Telephone: (888) 622-6992
FCC Compliance Statement: 47 CFR Part
15, Class A Digital Device
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) this device may not cause
harmful interference, and (2) this device must
accept any interference received, including
any interference that may cause undesired
operation.
Changes or modifications not expressly
approved by the party responsible for com-
pliance could void the user’s authority to
operate the equipment.
Canada—Innovation, Science, and Economic
Development Canada;
This device contains license-exempt
transmitter(s)/receiver(s) that comply with
Innovation, Science, and Economic Devel-
opment Canada’s license-exempt RSS(s).
Operation is subject to the following two
conditions:
(1) This device may not cause interference.
(2) This device must accept any intefrerence,
including interference tht may cause unde-
sired operation of the device.
Limitation of Liability
This Product has been designed for use to
reduce the risk of resident wandering through
remote detection.
The range, accuracy, function and performance
of this Product may vary from the published
specifications due to many factors, includ-
ing, without limitation, site impairments from
structural eects, metal objects in the vicinity,
placement of the receiver and transmitter, inter-
ference from other electrical devices, atmo-
spheric eects, installation, and maintenance.
There may be other factors, which also aect
performance of this Product.
STANLEY Healthcare does not guarantee
that this Product will detect 100% of resident
wanderings. STANLEY Healthcare does not
guarantee that this Product will not return false
reports of resident wandering.
Weekly testing and maintenance of this
Product, as described in the Product docu-
mentation, is essential to verify the system is
operating correctly and to ensure that the prob-
ability of detecting an alarm and/or locating the
transmitter are maximized.
The failure to undertake regular testing and
maintenance will increase the risk of system
failure and failure to detect resident wander-
ing. The failure to undertake regular testing
and maintenance will increase the risk of false
reports of resident wandering.
STANLEY Healthcare hereby disclaims all war-
ranties, express or implied, arising out of or in
connection with any of its Products or the use or
performance thereof, including but not limited
to, where allowable by law, all other implied
warranties or conditions of merchantable qual-
ity and fitness for a particular purpose and those
arising by statute or otherwise in law or from a
course of dealing or usage of trade.
STANLEY Healthcare’s liability to you or
anyone claiming through or on behalf of you
with respect to any claim or loss arising out of
the use or misuse of STANLEY Healthcare’s
Product, defective products or materials,
improper installation or maintenance of
STANLEY Healthcare’s Product or products or
the system in which they are incorporated, or
alleged to have resulted from an act or omis-
sion of STANLEY Healthcare or any person,
negligent or otherwise, shall be limited to:
A) the repair or replacement of defective Product
or materials supplied by STANLEY Healthcare
during the warranty period as set out in the
Product documentation; or, at the option of
STANLEY Healthcare,
B) a refund of the purchase price of the Product
supplied by STANLEY Healthcare.
In no event shall STANLEY Healthcare be
liable for general, specific, indirect, conse-
quential, incidental, exemplary or punitive
damages or any losses or expenses suf-
fered by you or anyone else, whether or not
STANLEY Healthcare, or its employees, o-
cers, agents, resellers or installers has been
informed of the risk of such loss or expense
and whether or not such losses or expenses
were foreseeable.
Introduction
The WanderGuard BLUE Wearable Bracelet
(Wearable) signals the WanderGuard BLUE
EX5700 Controller that it is in a monitored
door field and the Controller can lock the
door. The Wearable is worn on the wrist and
has the look and feel of a modern smart
watch.
There are three Wearable types: 3-Year
Wearable (WGB-TAG-2000-3Y) with 3-Year
battery life and 90 Days Wearable (WGB-
TAG-2000-90D) with 90-Days battery life that
transmits messages only when in EX5700
Controller range; the 1-Year Wearable (WGB-
TAG-2000-1Y) transmits messages every 20
seconds when not in the EX5700 Controller’s
range.
The type is indicated on the back label. The
M/N of the Wearable is WGB-TAG-2000-xx,
where xx is 90D, 1Y or 3Y.
Wearable Activation
The Wearable must be activated before
applying it to a resident’s wrist. Once
activated, a Wearable cannot be deactivated.
The Wearable is activated using the
WanderGuard BLUE Detector. Please refer to
the WanderGuard BLUE Deployment Guide.
Cleaning the Wearable
Follow these recommendations for cleaning
the Wearable.
• Use mild soap and water to remove
any apparent debris.
• Disinfect the Wearables by wiping
with an alcohol sanitizer or germicidal
cleaner for 60 seconds. Use only
cleaners marked as safe for plastics.
Wearables are incompatible with
disinfectants containing Glycol Ether.
• Dry with a soft, clean cloth.
• Do not use in an autoclave.
Wearable Wristband Types
Two types of bands are available for the
WanderGuard BLUE Wearable Wearable:
cut -resistant and non-cut resistant. For each
type, there are two possible lengths: short
and long. The Wearable Wearable is shipped
with the wristbands already attached and
ready to be applied to the residents.
Wristband Basic Parts
The wristband kit includes: the band; a
removable metal plate with two Metal Pins,
plus a plastic pin cover called the Locking
Clip; a fixed metal end pin plus a closer loop
called the Band Closer; and the Removal
Tool.
Removing the Wearable
1 Place the Removal Tool over the Lock-
ing Clip.
2 Squeeze the Removal Tool’s sides
together so that the Locking Clip’s ears
spring outward.
3 Remove the Locking Clip, and pull the
band out of the Metal Pins.
4 Take care to keep all parts for future use.
Applying the Wearable
1 Fit the band on the resident’s wrist with
the Wearable number facing outward.
2 Press the band holes on to the two
pins, so that the Metal Pins fully extend
through the band holes.
3 Place the Locking Clip on the Metal
Pins, and lock by pressing the two ears
inward.
4 Place the Band Closer’s hole over the
end pin, and press it through the hole
to complete the Wearable application
process.
Warranty
STANLEY Healthcare’s WanderGuard BLUE
Wearable Bracelets are warranted against
defects in materials and workmanship and
shall perform in accordance to published
specifications:
• WGB-TAG-2000-90D: 90 Days
• WGB-TAG-2000-1Y: 1 Year
• WGB-TAG-2000-3Y: 3 Years
The STANLEY Healthcare Wearable Brace-
let warranty is binding only if the Bracelet
was activated before the “Activate By” date
printed on the Bracelet back label. The war-
ranty starts when the Bracelet is activated.
Orderable SKU List
D Description SKU
Wearable: 90 Day, short
band, non-cut resistant WGB-TAG-2100-90D
Wearable: 1 year, short
band, non-cut resistant WGB-TAG-2100-1Y
Wearable: 3 years, short
band, non-cut resistant
WGB-TAG-2100-3Y
Wearable: 90 Day, short
band, cut resistant
WGB-TAG-2110-90D
Wearable: 1 year, short
band, cut resistant
WGB-TAG-2110-1Y
Wearable: 3 years, short
band, cut resistant
WGB-TAG-2110-3Y
Wearable: 90 Day, long
band, non-cut resistant
WGB-TAG-2200-90D
Wearable: 1 year, long
band, non-cut resistant
WGB-TAG-2200-1Y
Wearable: 3 years, long
band, non-cut resistant
WGB-TAG-2200-3Y
Wearable: 90 Day, long
band, cut resistant
WGB-TAG-2210-90D
Wearable: 1 year, long
band, cut resistant
WGB-TAG-2210-1Y
Wearable: 3 years, long
band, cut resistant
WGB-TAG-2210-3Y
Instructions for the WanderGuard® BLUE Wearable Bracelet

Other manuals for WanderGuard BLUE

1

This manual suits for next models

2

Other Stanley Healthcare Medical Equipment manuals

Stanley Healthcare T2s Tag User manual

Stanley Healthcare

Stanley Healthcare T2s Tag User manual

Stanley Healthcare Pedz Tag User manual

Stanley Healthcare

Stanley Healthcare Pedz Tag User manual

Stanley Healthcare AeroScout T12s User manual

Stanley Healthcare

Stanley Healthcare AeroScout T12s User manual

Stanley Healthcare Bed-Check Classic-Check Sensormat 72020 User manual

Stanley Healthcare

Stanley Healthcare Bed-Check Classic-Check Sensormat 72020 User manual

Stanley Healthcare Hugs User manual

Stanley Healthcare

Stanley Healthcare Hugs User manual

Stanley Healthcare Kisses Tag User manual

Stanley Healthcare

Stanley Healthcare Kisses Tag User manual

Stanley Healthcare AeroScout T15e User manual

Stanley Healthcare

Stanley Healthcare AeroScout T15e User manual

Popular Medical Equipment manuals by other brands

Barco Demetra user guide

Barco

Barco Demetra user guide

Nellcor OXIMAX N-560 Service manual

Nellcor

Nellcor OXIMAX N-560 Service manual

Konsung KSOC Series user manual

Konsung

Konsung KSOC Series user manual

Kinetec Maestra Series user manual

Kinetec

Kinetec Maestra Series user manual

FujiFilm XG5000 Service manual

FujiFilm

FujiFilm XG5000 Service manual

medi Spinomed IV Instructions for use

medi

medi Spinomed IV Instructions for use

Dräger Narkomed 2B Operator's instruction manual

Dräger

Dräger Narkomed 2B Operator's instruction manual

Gima VISIO 5 PLUS user manual

Gima

Gima VISIO 5 PLUS user manual

Hovertech HoverJack user manual

Hovertech

Hovertech HoverJack user manual

Sissel Desktop mobil operating manual

Sissel

Sissel Desktop mobil operating manual

i-Optik CV-7800 Operator's manual

i-Optik

i-Optik CV-7800 Operator's manual

nox A1 manual

nox

nox A1 manual

Whitehall Manufacturing T-4-S INSTRUCTIONS FOR OPERATION AND CARE OF

Whitehall Manufacturing

Whitehall Manufacturing T-4-S INSTRUCTIONS FOR OPERATION AND CARE OF

Sunbeam FlexTemp 901-825 instruction manual

Sunbeam

Sunbeam FlexTemp 901-825 instruction manual

Daavlin UV Series Operation manual

Daavlin

Daavlin UV Series Operation manual

Drive Medical 13003 Assembling instructions

Drive Medical

Drive Medical 13003 Assembling instructions

ProxiMity UV-Clean UVC-SM Product guide

ProxiMity

ProxiMity UV-Clean UVC-SM Product guide

Bard Soft-Cell Straight Instructions for use

Bard

Bard Soft-Cell Straight Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.