INS_APCH_0611
Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
Protect the heating unit with the appropriate circuit breaker or fuse, in accordance with the nameplate.
Make sure the line voltage (volt) is consistent with that indicated on the unit’s nameplate.
Connect to properly grounded outlets only. (This item may be omitted if the heater is not provided with a grounding type attachment plug.)
Switch off the power at the circuit breaker/fuse before installing, repairing and cleaning the unit. To disconnect heater, turn controls to off, then remove plug
from outlet.
Make sure the unit is appropriate for the intended use (if needed, refer to the product catalog or a representative).
Recommended heating capacity:
1.25 W/cubic foot (0.03 m³).
It corresponds to 10 watts / square foot (0.09 m²) based on a standard ceiling height of 8 feet (2.44 m). The recommended capacity is usually suf-
ficient for normal heating needs. Please note that the insulation quality of walls and windows are some of the factors that influence heat losses, which
modify the required capacity to heat a room. If needed, refer to a specialist (industrial and commercial buildings) who will be able to calculate these heat
losses and optimize the required capacity or consult the “Online heating calculation” section of the Stelpro Design Web site (residential buildings). To heat
a large room and to increase your comfort, it is recommended to install several units instead of one. For example, 2 X 1000 W rather than 1 X 2000 W.
If the unit capacity is insufficient for the size of the room, it will be in operation continuously, and may become defective earlier.
Respect distances and positions indicated in the installation section. Make sure the unit does not fall on its side.
Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
Do not use outdoors. (Omitted if the heater is intended for outdoor use.)
If the installer or the user modifies the unit, he will be held responsible for any damage resulting from this modification, and the CSA certification could be void.
This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water
container. Do not use it if any part has been immersed. Moreover, do not turn it on or off when standing in water or if your hands are wet.
Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange
cord away from traffic area and where it will not be tripped over. Always unplug heater when not in use. (This item may be omitted if the heater is provided
with a clock-operated switch).
Before starting the unit, make sure the power cord is fully inserted into the wall outlet. If it is a ceiling outlet, it is recommended to fix the connector to the
outlet using a proper clamp system.
Always plug heaters directly into a wall outlet/receptacle. Never use with an extension cord or re locatable power tap (outlet/power strip).
When starting up the unit for the first time or after a long period, it is normal that it produces some temporary odours and whitish smoke.
This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this heater. Be careful and
responsible when using it. The unit must cool down for few minutes since it will stay warm for some time after shut-down.
Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9 m) from the front of the heater and keep
them away from the sides and rear. Failure to comply with this warning could lead to a fire. Some materials are more heat-sensitive than others, so make sure
those near the unit can withstand heat. Please note that this unit is not designed to dry clothes.
To prevent a possible fire, do not block air intakes or exhausts in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked.
Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater.
A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, flammable liquids, chlorine, sawdust or cleaning products
are used or stored. Store it in a dry place when not using it.
Some areas are dustier than others. Thus, it is the user’s responsibility to evaluate if the unit must be cleaned based on the amount of dirt accumulated on
and inside air vents. Accumulated dirt can lead to a component malfunction. It may cause a fire hazard if not installed and maintained in accordance with
these instructions.
The thermal protection activation indicates that the unit has been subjected to abnormal operating conditions. If the thermal protection remains activated
or activates and deactivates repeatedly, it is recommended that a qualified electrician or a certified repair centre examine the unit in order to make sure it is
not damaged. (Refer to the limited warranty)
Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been dropped or damaged in any manner. Discard heater, or
return to authorized service facility for examination and/or repair.
This unit is equipped with a protection device whose activation is indicated by a light inside the unit, the protective device cuts off the supply to the unit
and warning light turn on. Unplug the unit, replug it and check if the light turns on again. If such is the case, disconnect the unit and have it repaired at a
recognized service center. Never modify or repair the unit yourself. Failure to follow these instructions may result in a fire.
This heater includes a visual alarm (red light) to warn that parts of the heater are overheating. If the red light turns on, immediately turn heater off and inspect
for any objects on or adjacent to the heater that may cause high temperatures. DO NOT OPERATE WHEN RED LIGHT IS ON.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons.
Read all instructions before using this heater.
Always unplug the heater when not in use.
To disconnect, turn controls to OFF, then remove plug from the outlet.
Avoid the use of an extension cord. Extension cords may overheat and cause risk of fire. If you must use an extension cord, the cord must be a No. 10 AWG
minimum size and rated no less than 6 kW.
Always use a certified electrician should new circuits or outlets be required.
Disconnect all power supplies before performing any cleaning, maintenance or relocation of the heater.
When transporting or storing the heater and cord, keep in a dry place, free from excessive vibration and store so as to avoid damage.
SAVE THESE INSTRUCTIONS
Note:
When a part of the product specification must be changed to improve operability or other functions, priority is given to the product specification itself. In such instances, the
instruction manual may not entirely match all the functions of the actual product.
Therefore, the actual product and packaging, as well as the name and illustration, may differ from the manual.