STI STI-SA5000 Series User manual

STI-SA5000 SERIES
SELECT-ALERT
ALARM MINI CONTROLLER
INSTRUCTION MANUAL
“We Protect The Things That Protect You.”
Safety Technology International, Inc.
Features:
• This controller can be used as a cabinet
alarm, door alarm, link with push but-
ton/switch or as a burglar alarm.
• Available with amber, green, blue, red
or white lens.
• Durable, polycarbonate construction.
• Includes ten high intensity ED’s.
• Siren offers 32 user selectable tones.
• May be set for a piercing 100 or 85 dB
alarm.
• For indoor use only.
• Independent strobe and siren timing
of 15 seconds, 30 seconds, 60 seconds
or continuous.
• Includes a tamper switch which trig-
gers the alarm when unit is being re-
moved from a wall.
• ow battery indicator.
• Powered by a 9 VDC battery (not in-
cluded) or external 12 – 30 volts.
• One Form “C” dry relay contact output.

2
Warnings and Cautions ......................................................................page 3
Warranty Information ........................................................................ page 3
Dimensions ........................................................................................page 3
Specifications ...................................................................................... page 4
Electronic Setup .................................................................................. page 4
Alarm Tones ........................................................................................page 5
Alarm Timing and Volume .................................................................. page 5
Terminal Strip Connections ................................................................ page 5
Mounting Options .............................................................................. page 6
Electronics .......................................................................................... page 7
CONTENTS
SELECT-ALERT ASSEMBLY ARTS LIST
ACCESSORIES
1 - 05000 Electronics Assembly
1 - 05050 Color Lens
4 - 19068 Screw #6 x 5/8 in.
4 - 19002 Screw #8-32 x 3/8 in.
2 - 19039 Screw #6 x 1 1/4 in.
2 - 19018 Anchor #8-10
2 - 19062 Screw #6-32 x 1 1/2 in.
1 - 19011 #8-32 x 1/2 in. tamper screw
1 - 19016 Tamper wrench
SUB-71100A-W Backbox kit
18151 N.C. reed switch and magnet
SUB-SA505 Key switch mounting bracket (includes key switch & 2 keys)
BAT-9VDC 9 volt battery
18075 Additional replacement key

WARNINGS
All units are recommended for indoor use. Unit must be tested periodically to
verify the life of battery. STI recommends you change the 9 Volt battery twice
a year. When purchasing a Select-Alert, you will need to periodically test the
connections to make sure audibles function at a sound level to alert staff. In-
staller may need to purchase a simple audio-meter, typically available at your
local electronics store, to measure the sound in areas where the alarm is ex-
pected to be heard during normal noise environment. Results from this test
may prove it beneficial to purchase additional Select-Alert units.
All specifications and information shown are current as of publication and sub-
ject to change without notice.
WARRANTY INFORMATION
Three year guarantee against breakage of polycarbonate housing in normal
use (one year on electro mechanical and electronic components).
DIMENSIONS
FRONT SIDE
3.25 in.
(83mm)
4.83 in.
(123mm)
1.58 in.
(40mm)
2.73 in.
(69mm)
3

STE 1 - ELECTRONIC SETU
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
TAMPER SWITCH
(REAR VIEW)
WIRE ENTRY
BATTERY
BATTERY CABLE
SIREN
O
4
S ECIFICATIONS
O ERATING VOLTAGE Internal power 9 VDC battery (not included)
Remote power 12-30 VDC
O ERATING TEM ERATURE 32°F -120°
OWER CONSUM TION Stand by: 50µA
Siren low volume: 85mA
Siren high volume: 90mA
Strobe: 25mA
SIREN VOLUME ow: 85 dB
High: 100 dB
ALARM TIMING Independent control for siren and strobe:
15s, 30s, 60s, continuous
LOW BATTERY WARNING ED flash once every 30 seconds
FORM C DRY CONTACTS 0-30VAC/DC, 1 Amp
Contacts reset after longest alarm setting
KEY SWITCH Alarm on: normally closed
ALARM SWITCH Stand by: normally open contact required
OLYCARBONATE U 94V-2
FLAMMABILITY RATING
INSTALLATION
NOTE: Select-Alert must be on a flat surface and lens must be in-
stalled or the tamper switch will trigger the alarm.

5
1 0 0 0 0 0 BUZZ
2 1 0 0 0 0 SLOW ON/OFF
3 0 1 0 0 0 SLOW SIREN
4 1 1 0 0 0 3 BEE / AUSE/RE EAT
5 0 0 1 0 0 UFO FAST
6 1 0 1 0 0 FAST SIREN
7 0 1 1 0 0 #5 FAST
8 1 1 1 0 0 #2 MEDIUM
9 0 0 0 1 0 #5 MEDIUM
10 1 0 0 1 0 SWOO MEDIUM
11 0 1 0 1 0 #3 MEDIUM
12 1 1 0 1 0 BUZZ TONE
13 0 0 1 1 0 STEADY FAST
14 1 0 1 1 0 SWOO SLOW
15 0 1 1 1 0 CONTINUOUS
16 1 1 1 1 0 FAST RE EAT
17 0 0 0 01 STANDARD ALARM
18 1 0 0 0 1 #3 FAST
19 0 1 0 0 1 #5 SLOW
20 1 1 0 0 1 FAST BEE
21 0 0 1 0 1 SOUND A
22 1 0 1 0 1 SOUND B
23 0 1 1 0 1 SOUND C
24 1 1 1 0 1 SOUND D
25 0 0 0 1 1 SOUND D LOUD
26 1 0 0 1 1 SOUND E
27 0 1 0 1 1 SOUND F
28 1 1 0 1 1 SOUND G
29 0 0 1 1 1 SOUND H
30 1 0 1 1 1 #4 LOW
31 0 1 1 1 1 SOUND K
32 1 1 1 1 1 CONTINUOUS FAST
1
ALARM TIMING VOLUME
STROBE TIMING
ON
OFF
1
2345
0
15 seconds 1 1 1 1 High
30 seconds 1 0 1 0 1
60 seconds 0 1 0 1 ow
Continuous 0 0 0 0 0
1 = ON 0 = OFF
STE 2 - ALARM TONES - S1
STE 3 - ALARM TIMING AND VOLUME - S2
STE 4 - TERMINAL STRI CONNECTIONS
REMOTE POWER IN
12-30 VDC, 125mA
+-OFF ON
**MAIN POWER
CONTROL
STAND
BY
ALARM
SWITCH
FORM "C"
DRY CONTACTS
NORMALLY OPEN
COM
+ -
DC IN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
NORMALLY CLOSED
ACTIVE
1 2 3 4 5 1 2 3 4 5
ALARM
TIMING 1 2 3 4 5
VOLUME
STROBESIREN
*Factory default settings
*
*
**Shipped with jumper
wire installed. Remove
to add key switch or
other main power
on/off switch.
NOTE: “DC IN” are the
only polarity sensi-
tive terminals .
When external
power is used, bat-
tery will act as a
backup. “Dry Con-
tacts: NC, COM,
NO” are used for
remote alarm
monitoring.
NOTE: Sound may be disabled by clipping wires to
the siren. THIS WI VOID A WARRANTIES.
Remove two screws on circuit board; leave
enough length of wire to possibly reattach in
the future. Then insulate wires to prevent
shorting to electronic components.
WIRES TO SIREN
O
O

6
DRILL (4) 3/16 in. DIA. HOLES IF USING #8-10 ANCHORS.
DRILL (4) 3/32 in. DIA. HOLES WHEN USING #6 SCREWS ONLY.
19018 ANCHOR
#8-10
(4) PROVIDED
SUB-71100A-W
19039 SCREW
#6 x 1 1/4 in.
(4) PROVIDED
19060 SCREW
#6-32 x 1 in.
(2) PROVIDED
BASE PLATE
A) TO STI BACKBOX SUB-71100A-W
B) TOKEY MOUNT LATE OR INTO WALL WITHOUT ELECTRICAL BOX
STE 5 - MOUNTING O TIONS
NOTE: For bare wall installation, wire access hole may need to be drilled.
O
DRILL
3-/16 DIA HOLES
19018 ANCHOR
#8-10
(2) PROVIDED
19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED
BASE PLATE
18074 SWITCH LOCK
SUB-SA505 KEY SWITCH
MOUNTING BRACKET
3 9/32 in.
18075 REPLACEMENT
#801 KEY
O
1. Using 5/32 drill, drill through the (4) existing holes in backbox (one in each corner).
2. Place backbox on wall and mark the mounting hole positions.
3. If using #8-10 anchors, drill 3/16 dia. holes 1 in. deep into wall and press anchor into hole.
If using #6 screws only, drill 3/32 dia. holes 1 ¼ in. deep.
4. Mount backbox to wall using #6 x 1 ¼ in. screws.
5. Mount base plate as shown using (2) #6-32 x 1 in. screws.
NOTE: If not using STI backbox, make sure surface will depress tamper switch.
ENCLOSURE
ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN
E

7
O
SINGLE GANG
ELECTRICAL BOX
19062 SCREW
#6-32 x 1 1/2 in.
(2) PROVIDED
BASE PLATE
O
05050- LENS COLORS
A - AMBER
B - BLUE
G - GREEN
R - RED
W - WHITE
19002 SCREW
#8-32 x 3/8 in.
(4) PROVIDED
05000 ELECTRONICS
INSTALLED
BASE PLATE
WIRE ACCESS HOLE
19016 TAMPER-PROOF
TOOL (1) PROVIDED
19011 TAMPER-PROOF
SCREW
ROUTE WIRES
THRU HOLE
STE 6 - ELECTRONICS FINAL ASSEMBLY
C) TOSINGLE GANG ELECTRICAL BOX
Wiring: After mounting circuit board assembly, connect wires. Refer to terminal strip connections (step 4).
Lens installation: Slide lip of lens behind circuit board mounting plate. Rotate lens into position. Secure with
tamperproof screw and special wrench.

Printed in USA Inst. Sht. SA5000, FEB2012
Safety Technology International, Inc.
2306 Airport Road
Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Toll Free: 800-888-4784 • Fax: 248-673-1246
Safety Technology International (Europe) Ltd.
Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch
Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only)
E-mail: info@sti-europe.com • Web: www.sti-europe.com
STE 7 - O ERATION
• Turn key switch on to arm.
• Cycle key switch to reset alarm.
• Alarm will sound when cover is removed, unit is removed from the wall or
cabinet is opened (alarm switch is electronically closed).
• To service, turn key switch off.
Table of contents
Other STI Controllers manuals

STI
STI SA5000 Series Instruction sheet

STI
STI SC/BQ User manual

STI
STI MC4 Series User manual

STI
STI STI-SA5000 Series User manual

STI
STI RTQ Series User manual

STI
STI MC6 Series User manual

STI
STI Select-Alert STI-SA5000 Series User manual

STI
STI QuadSafe RM-4 User manual

STI
STI SA5000 Series User manual

STI
STI SC Operating and maintenance manual