manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Swegon
  6. •
  7. Fan
  8. •
  9. Swegon EAGLE Ceiling Guide

Swegon EAGLE Ceiling Guide

Other manuals for EAGLE Ceiling

1

This manual suits for next models

1

Other Swegon Fan manuals

Swegon EAGLE Free g Guide

Swegon

Swegon EAGLE Free g Guide

Swegon SILVER C User manual

Swegon

Swegon SILVER C User manual

Swegon HAWK Ceiling User manual

Swegon

Swegon HAWK Ceiling User manual

Swegon HAWK Ceiling User manual

Swegon

Swegon HAWK Ceiling User manual

Swegon DOMO C Guide

Swegon

Swegon DOMO C Guide

Swegon ADAPT Parasol EXb User manual

Swegon

Swegon ADAPT Parasol EXb User manual

Swegon KDYa Series Guide

Swegon

Swegon KDYa Series Guide

Swegon GOLD PX Series Troubleshooting guide

Swegon

Swegon GOLD PX Series Troubleshooting guide

Swegon ADAPT Extract Guide

Swegon

Swegon ADAPT Extract Guide

Swegon PARAGON Wall VAV Guide

Swegon

Swegon PARAGON Wall VAV Guide

Swegon WISE Damper a User manual

Swegon

Swegon WISE Damper a User manual

Swegon EAGLE Free f Guide

Swegon

Swegon EAGLE Free f Guide

Swegon LOCKZONE Ceiling a Guide

Swegon

Swegon LOCKZONE Ceiling a Guide

Swegon GOLD PX User manual

Swegon

Swegon GOLD PX User manual

Swegon CASA W3 Smart User manual

Swegon

Swegon CASA W3 Smart User manual

Swegon PARASOL VAV Series Guide

Swegon

Swegon PARASOL VAV Series Guide

Swegon PARASOL c Series Guide

Swegon

Swegon PARASOL c Series Guide

Swegon WISE Paragon d User manual

Swegon

Swegon WISE Paragon d User manual

Swegon ADAPT Parasol b 600 Guide

Swegon

Swegon ADAPT Parasol b 600 Guide

Swegon CASA PR085LKA User manual

Swegon

Swegon CASA PR085LKA User manual

Swegon ADAPT Colibri c Guide

Swegon

Swegon ADAPT Colibri c Guide

Swegon ADAPT Parasol b User manual

Swegon

Swegon ADAPT Parasol b User manual

Swegon GOLD RX User manual

Swegon

Swegon GOLD RX User manual

Swegon ADAPT Extract d Guide

Swegon

Swegon ADAPT Extract d Guide

Popular Fan manuals by other brands

Minka Group minkaAire Wave F843 instruction manual

Minka Group

Minka Group minkaAire Wave F843 instruction manual

Airflow Adroit DV50 instruction manual

Airflow

Airflow Adroit DV50 instruction manual

Vornado 270 Series owner's guide

Vornado

Vornado 270 Series owner's guide

comfort air TH-10D instruction manual

comfort air

comfort air TH-10D instruction manual

Livoo DOM386 instruction manual

Livoo

Livoo DOM386 instruction manual

Holmes BLIZZARD HAOF-90 owner's guide

Holmes

Holmes BLIZZARD HAOF-90 owner's guide

Taurus GRECO 16 ELEGANCE manual

Taurus

Taurus GRECO 16 ELEGANCE manual

Quorum PINNACLE installation instructions

Quorum

Quorum PINNACLE installation instructions

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Craftmade UH52 installation guide

Craftmade

Craftmade UH52 installation guide

Jocel JVA030658 instruction manual

Jocel

Jocel JVA030658 instruction manual

MIKA MFB1211/GR user manual

MIKA

MIKA MFB1211/GR user manual

Harbor Breeze RLG52NWZ5L manual

Harbor Breeze

Harbor Breeze RLG52NWZ5L manual

Allen + Roth L1405 instruction manual

Allen + Roth

Allen + Roth L1405 instruction manual

ViM KUBAIR F400 ECOWATT Technical manual

ViM

ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA R10R-56LPS-ES50B-04C10 user guide

HIDRIA

HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering HEAT BUSTER SPL Series owner's manual

Triangle Engineering

Triangle Engineering HEAT BUSTER SPL Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
EAGLETM Wall
Installation - Commissioning - Maintenance
Installation
See Figure 1.
1. Cut the opening in the wall. The size of the opening
should be according to dimensions I x J, which are
given in the Dimensions table on page 2.
2. Place the commissioning box in the opening.
3. Insert the mounting frame into the commissioning box
and secure it with screws in the short sides to the com-
missioning box and to the wall structure.
4. Insert to air distribution baffle into the mounting frame
and lock it in position by means of wing nuts.
5. Press the diffuser face to engage it in the mounting
frame.
Commissioning
Commissioning must be carried out with the diffuser face
mounted. Pull the measuring tube and the damper adjust-
ment cords out of the air diffuser through a disc. Connect
a manometer to the measuring tube. The desired commis-
sioning pressure can be calculated using the rated coef-
ficient of performance of the air diffuser. Set the damper
to the correct blade position, tie a commissioning knot in
the damper cords to indicate the damper position, then
lock the cords.
Maintenance
The air diffuser can be cleaned, if necessary, using luke-
warm water with dishwashing detergent added or by
vacuum cleaning using a brush nozzle. The duct system
can be accessed after the air diffuser section has been
removed, the acoustic baffle has been withdrawn, the air
distribution discs have been moved to the side and the
damper has been turned and withdrawn from its fastener
from the inlet. See Figure 1.
Environment
The Building Materials Declaration is available from www.
swegon.com.
Figure 1. Installation. Commissioning.
p
q
k-factor
EAGLE Wall
Tomelilla
Sweden
400-200
+ALVT1 400-200-160-B
k-faktor=14,6/27,8
k
kpq⋅=
k
pq
=
( )2
q = Flow reading l/s
p = Current pressure reading (Pa)
k = Commissioning factor
2
EAGLE Wall
Swegon reserves the right to alter specifications. 20100929 www.swegon.com
ALVT 1 frame
Size A B L
300-150 330 180 230
400-150 430 180 230
400-200 430 230 230
550-250 580 280 255
550-300 580 330 255
Figure 3. ALVT 1 frame.
Dimensions and Weights
EAGLE W
Size A B ØD F G G2
300-150 330 180 99 295-375 225-305 270-350
400-150 430 180 124 295-375 225-305 331-411
400-200 430 230 159 315-395 225-305 331-411
550-250 580 280 199 360-440 251-331 371-451
550-300 580 330 249 385-465 251-331 425-505
Size of opening = I x J
The G2, K, L and M dimensions are applicable to a side-connec-
ted commissioning box.
Figure 2. EAGLE Wall with ALV commissioning box.
Rated coefficient of
performance
EAGLE W and ALV
ALVd EAGLE Wall, supply air
Connection, rear Connection, short side
Size Size Closed slot Open slot Closed slot Open slot
300-150-100 300-100 7.8 9.2 7.2 8.1
400-150-125 400-150 9.9 11.8 9.6 11.1
400-200-160 400-200 14.8 17.1 14 15.9
550-250-200 550-250 25.5 27.8 24.4 26.8
550-300-250 550-300 31.1 33.9 30.5 33.4
Size K L M I x J Weight,
kg
300-150 85 145-225 195-275 305 x 155 3.0
400-150 85 180-260 240-320 405 x 155 3.5
400-200 100 145-225 225-305 405 x 205 4.0
550-250 120 145-225 245-325 555 x 255 6.5
550-300 145 145-225 275-355 555 x 305 7.5