SWIT BM-H Series User manual

Model:BM-H215/215HDR/245
User Manual
Please read this user manual throughout before using
Ver:A
SWIT ELECTRONICS CO., LTD.
01
4K input FHD Broadcast Monitor
BM-H

Declaration
Any internal technology (including hardware equipment, software design and product trademark)
of the product shall be protected by law, and any infringement of intellectual property rights of the
product shall be investigated for legal liability。
All the brand and trademark in this product are protected by law,all other company’s brand and
trademark in this product are protected by their owner’s law.
In order to better service majority users,SWIT products will keep improving and developing,SWIT
keep the right to revise and improve this user manual without previous notice.
The warranty period of this product are two years,the following condition are not covered by the
warranty:
⑴ The appearance and the LCD panel are damaged by man-made out force;
⑵ The amount of defective pixels are under three;
⑶ Damage the product by using incompatible power adaptor;
⑷ Damage the product due to violation operation;
⑸ Disassemble the product when using;
⑹ Other faults or damages not caused by design ,technology,manufacture and quality.
*Any sales person have no right to provide extra warranty beyond these terms.
If you have any advises or requirements about our products during using,please feel free to contact
with us via phone or E-mail.
This manual is applicable to all models of BM-H monitors. The schematic diagram of BM-H215 is
taken as an example.Any specification, appearance of the different, this manual will be attached
with text.
SWIT Electronics Co., Ltd.
Address: 10 Hengtong Road, Nanjing Economic and Technological Development Zone,
Nanjing 210038, P.R.China
Phone: +86-25-85805753
Fax: +86-25-85805296
Email: cont[email protected]
http://www.swit.cc
02
4K input FHD Broadcast Monitor
BM-H

Maintaince percautions
Warning
1. To reduce the dangerous of fire or electric shock,do not expose the monitor in raining or wet place.
2. The monitor will create noise when using near high-intensity magnetic field.
Precautions for power supply
1. Please use the special power adapter specified by the original factory to avoid damage to the product.
2. If other DC power supply is used, ensure that the voltage range, power supply and polarity of the
power supply meet the requirements.
3. In the following cases, please unplug the power cord and external battery of the product:
(A) If you have not used the product for A long period of time.
(B) If the power cord or power plug/socket is damaged.
(C) If the product is hit or dropped so that the shell is damaged.
Precautions for product use
1. Please do not touch the screen surface directly with your fingers to avoid damage to the screen,
and the oil on the skin will be difficult to remove if left on the screen.
2. Please do not put pressure on the LCD screen, LCD screen is very delicate and fragile.
3. Do not place the product in an unstable place, as the product may be seriously damaged due to falling.
Precautions for product cleaning
1. Clean LCD screen, please use dry soft fabric with fluff and special liquid crystal cleaning agent,
to remove dust and stains on the screen.
2. Do not pressure when wiping the LCD screen surface.
3. Please do not use water and other chemical cleaners to wipe the LCD screen surface,
chemical agents may damage the LCD screen surface.
03

Introduction
This series of monitors adopt LCD panel, the resolution is up to 1920×1080, H178° / V178°
ultra-wide viewing angle, supports 1 channels of 12G/6G/3G/HD/ SD-SDI and has 1 channels of
3G/HD/ SD-SDI, and 1 channel of HDMI 2.0, and has 1 channels of 3G/HD/ SD-SDI 、1 channels of
12G/6G/3G/HD/ SD-SDI ring out, with earphone and speaker output.
Features:
1920×1080 IPS LCD Panel
4K/UHD interface, (1x12G-SDI&3x3G-SD Input,2xSDI output,1xHDMI 2.0 Input)
16ch audio bar display, with any selected 2ch output
Support waveform selection display Y/Cb/Cr/R/G/B /RGB and single line selection mode
Vector scope, R/G/B/Y histogram, bi-color focus assist
3DLUT(17 x 17 x 17) accurate color correction
Dynamic UMD and TALLY(TSL3.1, 4.0) display
Composition ratio auxiliary line:4:3/13:9/14:9/15:9/16:9/1.85:1/2.35:1/2:1/2.39:1/Custom 1/Custom 2
Support USB firmware upgrade and import Log file.(USB file system supports FAT 32 format only)
Support ECO mode
Packing list
Standard accessories
Monitor
User manual
Warranty card
Battery plate(A & S)
Monitor stand
Power cable
Quantities
X
1
X
1
X
1
X
1
X
2
X
1
No.
1
2
3
4
5
6
04
Contents
Declaration
Precaution
Content
Packing list
Introduction
Description
Front panel
Back panel
Display information
Setting
Dimension
Specification
Trouble shooting
2
3
4
4
4
5
5
7
8
11
23
24
27

05
Operation Instructions
·Front panel
(1) Speaker: For SDI/HDMI embedded audio. (Will not work if earphone is plugged in)
(2) F1~F5 function keys: Customize shortcut function keys. Users can set the shortcut keys to
different functions according to their own requirements.
(3) User1~User4:User shortcut key, which can be used to quickly enter the set user mode.
Long press to save user settings. Please see details in “9. System”
(4) INFO:Display setting item. Press "INFO" button to display or turn off relevant status information
and audio and video analysis function graph. When opening the menu, press "INFO" to exit the
menu with one click
(1) (2) (3) (4) (5) (6) (7)(8) (9) (10)
(11)

06
(6) Menu/Enter:When no Menu is displayed, press the button directly to open the Main Menu;
Rotate the knob to select different settings or adjust parameter values, press the knob to set;
(7) LUT/Firmware: Update firmware or import LUT files;
(8) PHONE: 3.5mm headphone jack is used to monitor the embedded audio signals of SDI and HDMI;
(9) Power: Power switch;
(10) Tally lamp: You can select the color of the tally lamp from “Green”, “Red”, or “Yellow”.
(5)
Brightness Contrast Saturation
Backlight Volume Source
Brightness: Adjust the brightness. -100~100 adjustable,
default value is 0.
Contrast: Adjust contrast. -100~100 adjustable,
default value is 0.
Saturation: Adjust saturation. -100~100 adjustable,
default value is 0.
Backlight: Adjust the backlight. 0~100 adjustable, default
value is 16.
Volume:Adjust the volume.0~100 adjustable,
default value is 36.
Press Brightness, Contrast, Saturation, Backlight, Volume five shortcut keys confirm to select
this option, and rotate Menu to adjust the corresponding item value directly. Press the button
and automatically cancel the selection without operation within five seconds, and the button
light will be off, long press to restore default values;: Adjust the volume.0~100 adjustable, the
default value is 36.Long press the volume button to mute.
Source: Select the input source signal format.
Source
SDI 1
SDI 2
SDI 3
SDI 4
4xSDI SQD
4xSDI 2SI
HDMI
Multiview

07
·Rear panel
(1) SDI1 IN&OUT:12G/6G/3G/HD/SD-SDI
(2) SDI2 IN&OUT, SDI3 IN,SDI4 IN: 3G/HD/SD-SDI
(3) ETHERNET(Network interface):1000M high-speed RJ45 Ethernet port,for web external control
(4) HDMI 2.0 IN:Will not display HDCP protected content
(5) RS485:TSL UMD control port
(6) GPI:GPI control port
(7) Fan
(8) VESA bracket mounting area
(9) DC IN:12V~17V
(10) AC IN:100V~240V
(11) Battery plate
(3)
(2)
(1)
(4)
(5)
(6)
(11)
(7) (8) (9) (10)

⑴ Time Code(SDI)
Under SDI input, the monitor can display Time code information (LTC, VITC1&2). If no Time code info
is detected, it will display “TC UNLOCKED”. User can set function keys F1~F5 or GPI pins as “Time
Code” to turn on or off this function.
(2)Surround
The default channel of surround is 5.1 channel 7 & 8
⑶ On screen TALLY
Display TALLY signal from GPI control port.
⑷ Source ID/UMD
Display /UMD(TSL3.1/4.0),user can set in the UMD menu
⑸ Color checker
After auto calibration, the color gamut and chromatic aberration (△E) before and after the color
correction pop up. "Auto Calibration" -"Measure" pops up the gamut value and color difference
value (△E) of the previous calibration and this measurement.
⑹ Audio VU/PPM meters
Display meters of SDI/HDMI embedded audio or analog audio. The audio meter display channels,
on screen positions and background blending are adjustable. can be set in the submenu of“Audio
setting ”.User can set function keys F1~F5 or GPI pins as “Audio Bar” to turn on or off this function.
⑺ Histogram
User can set function keys F1~F5 or GPI pins as “Histogram” to turn on or off this function.
⑻ Vector
User can set function keys F1~F5 or GPI pins as“vector”, The vector scope pattern display positions,
08
·OSD
(1) SDI1 IN&OUT:12G/6G/3G/HD/SD-SDI
(2) SDI2 IN&OUT, SDI3 IN,SDI4 IN: 3G/HD/SD-SDI
(3) ETHERNET(Network interface):1000M high-speed RJ45 Ethernet port,for web external control
(4) HDMI 2.0 IN:Will not display HDCP protected content
(5) RS485:TSL UMD control port
(6) GPI:GPI control port
(7) Fan
(8) VESA bracket mounting area
(9) DC IN:12V~17V
(10) AC IN:100V~240V
(11) Battery plate
TC UNLOCKED
CAMERA
L -20DB 01CH R -22DB 01CH
-09
-20
-48
C
LR
Ls Rs
R
R75
Mg
Mg75
B
B75
Cy
Cy75
G
G75
YI
YI75
W
Delta = 1.0
R
R75
Mg
Mg75
B
B75
Cy
Cy75
G
G75
YI
YI75
W
Delta = 0.0
(1)
(2)
(3)
(4)
(5)
(6) (7) (8) (9)

09
Key configuration
Steps
1. Press “Menu/ Enter” button, the main menu will pop up from the left top of the screen. The selected
main menu highlights in yellow .
2. Revolve “Menu/ Enter” to select submenu, the selected submenu highlights in yellow, press “Menu/
Enter” to apply and enter into the selected submenu’s items.
3. Revolve “Menu/ Enter” to select the item which needed to adjust, press “Menu/ Enter”, the selected
item and its parameters will be highlighted in yellow
4. Revolve “Menu/ Enter” to change the selected item’s parameter, press “Menu/ Enter” to apply and
save the settings.
5. Revolve “Menu/ Enter” to select “Exit”, press “Menu/ Enter” to quit submenu. Select “Exit & Status”
under the Main Menu and press to quit Main Menu
※ Notice
* The items in gray cannot be set up
* If there is no operation under the set time, the menu will automatically save settings and quit.
* If the key inhabit function is turned on, except System menu, all other items are in gray. Please
turn off the key inhibit function to adjust the items.
colors, background are adjustable. Turning on the gamut map in the case of turning on the vector map
can display the gamut ratio of the signal image under DCI-P3/REC709/REC2020
⑼ Waveform
User can set function keys F1~F5 or GPI pins as “Waveform” to turn on or off this function.

Menu Configuration
Menu configuration introduces the main menu and each sub-menu. Menu items marked * will give
more detailed menu description or operation explanation after the list
10
1.Exit&Status—Exit the main menu and display the current status of the monitor
2.Input—Set the color of input video
3.Image setting—Setting for the picture preference
*1 Quantization range: Sets the quantization range of the video to suit the input video signal. The default
video quantization range is Limited 64-940 for the broadcast application.
Menu Item
Input Range*1
Red Gain
Green Gain
Blue Gain
Red Bias
Green Bias
Blue Bias
Reset
Menu description
Set the input range of input video
Adjust Red Gain
Adjust Green Gain
Adjust Blue Gain
Adjust Red Bias
Adjust Green Bias
Adjust Blue Bias
Reset the gain and bias values of the settings
Value
Full 0-1023、
SDI Full 4-1019、
Limited 64-940
-100 ~ +100
-100 ~ +100
-100 ~ +100
-100 ~ +100
-100 ~ +100
-100 ~ +100
/
Main Menu
Exit&Status
Input
Picture
Color Management
Scanning
Control
Assist
De-embed
Auto Calibration
System
Multiview Setting >
Format
Source
Color Temp
F1
F2
F3
F4
F5
Profile Type
Version
Status
(1)
(6)
(5)
(4)
(3)
(2)
>
>
>
>
>
>
>
>
>
XX
XX
XX
XXX
XXX
XXX
XXX
XXX
XX
XX
>
>
>
>
>
>
⑵ Input source
Displays the currently selected channel.
(3)Colour temperature
Displays the currently set colour temperature mode
(4) Function key 1 to function key 5
Displays the function value of the current function key setting
(5) Model
Shows the current monitor model
(6)Versions
Shows the current software version number
Press "Menu/Enter" to bring up the main
menu in the top left corner of the screen,
the main menu shows the current working
status of the monitor.
⑴ Format
The current input signal standard is
displayed; if there is no recognisable
signal input, "No signal" is displayed.
When multi-screen is selected for the
current channel, the standard of the
input signal for each of the four SDI
1/2/3/4 channels is displayed.

11
Menu item
Contrast
Brightness
Saturation
Sharpness
Backlight
Menu description
Adjust contrast
Adjust brightness
Adjust saturation
Adjust sharpness
Adjust backlight
Value
-100 ~ +100
-100 ~ +100
-100 ~ +100
0 ~ +100
0 ~ +100
4.Color Management—Setting about video colors
Menu item
Color gamut *1
Gamma*2
Menu Description
Set gamut values
Set gamma values
Value
LCD Native,DCI-P3,Rec.709,Rec.2020
1.0,1.8,2.2,2.4,2.6,PQ1000,HLG1000,S-Log3
Gamut and
gamma
values are
set to menu
items with
specific
values
HLG System
Gamma *3
D-Log to 709
D-Log to PQ
Set HLG System Gamma
Set gamut to Rec.709 camera table
Camera table when gamut is set to
Rec.2020 and gamma value is PQ1000
1.0,1.1,1.2(default),1.3,1.4,1.5
OFF,J-Log1,Log-C,S-Log2,C-Log,V-Log,RedLogFilm,
S-Log3,User-Log
OFF, ARRI_LogC_PQ,Canon_CLog2Cin_PQ
Canon_CLog3Cin_PQ,Panasonic_VLog_PQ,
RED_L3G10_PQ,Sony_SLog3_Cin_PQ,
Sony_SLog3_SG3_PQ
Camera table when gamut is set to
Rec.2020 and gamma value is HLG1000
OFF,ARRI_LogC_HLG,Canon_CLog2Cin_HLG
Canon_CLog3Cin_HLG,Panasonic_VLog_HLG,
RED_L3G10_HLG,Sony_SLog3_Cin_HLG,
Sony_SLog3_SG3_HLG
D-Log to HLG
Multi gamut*4
Color temp
User temp
G/M
LUT import*5
Reset LUT
Multi-colour gamut on,off
Set screen display colour temperature
values
Set the user color temperature value
when the color temperature mode is
selected as “USER 1/USER2”
Set the user color temperature value
when the color temperature mode is
selected as “USER 1/USER2”
Select the cube file you want to import
Select the appropriate cube file to
restore to factory settings
OFF,ON
D55,D65,D75,D93,DCI,USER1,USER2
4000K~9800K
-100 ~ +100
None,3DLut.cube,User-Log.cube
NO,3DLut.cube
*1 Color gamut
Set the gamut to match the input audio.
*2 Gamma
When Four-screen is selected; the gamma of four signals can be adjusted separately for display
*3 HLG System Gamma
Display tunable only when Gamma is set to HLG1000

12
5. Scanning—Setting for picture scan, zoom, etc.
Menu Item
Scanning*1
Zoom Mode*2
Freeze Frame
Odd/Even Frame*3
Menu Description
Set up a scanning mode that matches the audio to
the screen
Set a zoom mode
Select an image still mode
Set to open odd field or even field
Value
Pixel To Pixel, Panel Fit, Native
OFF, Top Left, Top, Top Right, Left, Center,
Right, Bottom Left, Bottom ,Bottom Right
OFF, ON
OFF, Odd Frame, Even Frame
*1. Scanning Panel Fit: Turn on this feature to adapt the video to the entire screen.
Native only displays the original mode in the specified mode.
*2. Zoom mode: Shown below, the image is divided into 9 regions and adjusted to display
in sequence.
When the zoom mode is turned on, a rectangle box pops up at the bottom left of the screen, showing the currently
selected zoom image area;Open Low Latency Mode,Zoom mode function is turned off.
*3.Odd/Even Frame Odd/Even Frame is only displayed in I mode. Open Low Latency Mode and Odd/Even Frame
function is turned off.
*4 Multi-colour gamut
Individual colour gamut for multi-colour gamut, gamma can be adjusted individually,
multi-colour gamut default colour gamut Rec.2020, gamma 2.2.
*5 LUT import
Place the cube file that needs to import the monitor in the root directory of the u-disk,
insert the u-disk into the USB interface on the front shell of the monitor, and choose to
import the corresponding file

13
6.Control—Setting for TALLY, UMD, IP control to the monitor
Menu Description
Open or close GPI Control
Set the function of each
pin for GPI terminal
Switch on/off Tally light
Set the display position of On
Screen Tally Lamp
Set the control function of the
function key
Open or close UMD display
Set the color of UMD characters
Set the position of UMD characters
Set the size of UMD characters
Show the transparency of the UMD
background
Set display UMD or source name
characters
Set the location of RS485
Fixed for 115200
Set the character that the source
name displays
Menu Item
GPI Control *1
GPI 1Pin
GPI 2Pin
GPI 3Pin
GPI 4Pin
GPI 5Pin
GPI 6Pin
Tally Setting
Tally Position
F1
F2
F3
F4
F5
UMD *2
UMD Color
UMD Position
UMD Size
UMD Blending
Display Type
RS485 Address
Baud Rate
Source ID
Value
OFF,ON
SDI1, SDI2, SDI3, SDI4, 4×SDI(2-SI)、
4×SDI(SQ), HDMI, Red Tally, Green Tally,
Yellow Tally ,Time Code, Freeze Frame,
WFM Type, WFM Single Line, UMD,
Marker , Waveform, Audio Bar, Zebra,
Vector, Low Latency Mode, Histogram,
Focus Assist , False Color
OFF, ON, Blinking
Top, Bottom
Time Code, Color Temp, Freeze Frame ,
Waveform, Waveform Type , UMD, Marker,
H/V Delay, Blue Only, Audio Bar, Zebra,
Vector, Low Latency mode, Histogram,
Odd/Even Frame , Focus Assist ,False
Color,CIE
OFF, ON
White,Red,Green,Blue,Black,Gray
Top,Bottom
Large, Small
OFF, LOW, HIGH
Source ID, TSL3.1,TSL4.0
1~126
115200,8,n,1/38400,8,n,1/9600,8,n,1
A-Z, a-z, 0-9, [\]^_`{l}~@?>=<,,/.-+*
()’&%$#’’!

Cascade:
14
*1 GPI control
Connect the GPI remote control terminal through the GPI interface on the real panel of the monitor,
turn on “GPI control” and set the function of GPI 1-6 buttons.
The GPI control allows you to control both the Tally
light and the on screen TALLY light at the same time:
*2 UMD
Select the display type as “UMD”, which can be controlled with TSL UMD.
Pin No
1
2
3
4
5
6
7
8
RS 485 IN
GND
NC
RXD-
NC
NC
RXD+
TXD-
TXD+
RS 485 OUT
GND
NC
RXD-
NC
NC
RXD+
TXD-
TXD+
Soft Tally Soft TallyTally

15
7. Assist— Setting for Vector scope and Histogram patterns.
Menu Item
False Color
Blue Only
Focus Assist
Zebra
Menu Description
Turn false color display on or off
Turn blue only on or off
Turn on or off focus assist and adjust the
color of the focus assist
Turn zebra on or off
Value
OFF, ON
OFF, ON
OFF, Blue, Red
OFF, ON
Waveform
WFM Type
WFM Position
WFM Blending
WFM Brigh
WFM Color
WFM Single Line*1
WFM Line Count
Vector
Waveform
Turn waveform on or off
Set the WFM Type
Set the WFM position
Set the blending of the background color of the
waveform
Set the brightness within a WFM image
Set the color of the waveform displayed on the
waveform chart
Switch on single line waveform
Set a line for the single line waveform
OFF, ON
Y, Cb, Cr, R,G,B,RGB
Bottom Left, Bottom
Right, Top Left, Top Right
OFF, High, Low
Low, Medium, High
White, Green, Color
OFF, ON
1-1080
Vector
Vector Position
Vector Blending
Vector Brigh
Vector Color
Turn vector on or off
Adjust the position of the vector on the screen
Vector scope transparency selection
Set the brightness within a vector image
Set vector colors
OFF, ON
Bottom Left, Bottom
Right, Top Left, Top Right
OFF, LOW, HIGH
Low, Medium, High
White, Green, Color
CIE
CIE Position
CIE Blending
CIE Bright
CIE Color
Histogram
Marker
Eye pattern*3
CIE
Turn the colour gamut chart on or off
Adjusting the position of the colour gamut map on
the screen
Set the transparency of the background colour of
the colour gamut map
Set the brightness within the colour gamut map
chart
Set gamut map colours
On,Off
Top left, Top right, Bottom
left, Bottom right
Off, Low, High
Low, Medium, High
White, green, colour
Histogram
Histogram Position
Histogram Blending
Turn histogram on or off
Set the display position on the histogram screen
Set the transparency of histogram background color
OFF, ON
Top left, Top right, Bottom
left, Bottom right
OFF, LOW, HIGH
Marker
Marker Select
Horizontal*2
Vertical
Safety area
Fit Marker
Center Marker
Marker Color
Marker type
Marker background
Turn marker on or off
Set the scale of the market line
Set the X ‒ axis value of the marker
Set the Y ‒ axis value of the marker
Set safety area percentage
Set safety area to fit marker ratio or not
Switch on the center cross marker
Select a color for marker
Set the display type of marker
Marker outside color setting
OFF, ON
16:9,15:9,14:9,13:9,4:3,2.
35:1,2:1,1.85:1,2.39:1,
Custom1,Custom2
50%~99%(0~1920)
50%~99%(0~1080)
80%~100%
OFF, ON
OFF, ON
White, Red, Green, Blue,
Black, Gray
Type 1,type 2
OFF, Black, Gray
Turn eye pattern on or off ON,OFF

16
*1 WFM Single Line
Open waveform single-line mode, the monitor shows only one line of audio waveform.
Rotate the Menu/Enter knob to select the number of lines of audio signal to display the
waveform. (The selection range of the number of lines in a waveform depends on the
current signal standard)
*2 X-axis/Y-axis position
When marker select is USER 1, Users can adjust the X position and Y position of the marking
line according to their own needs,Coordinate value is adjustable from 50% to 99%;when
marker select is USER2,the value of X-axis is adjustable between 0~1920,the value of Y-axis
is adjustable between 0~1080.
8. De-embed— Setting for video/audio analysis functions
Y
WFM Single Line:OFF WFM Single Line:ON
Y
64 64
256 256
512 512
768 768
940 940
Line:1
Menu Item
Audio Meter
Lissajous
Surround
Phase
Left Channel*2
Right Channel
Volume
Volume
Time code
H/V Delay*3
Menu Description
Audio Meter
Audio meter Position
Audio meter Blending
Audio meter marker *1
Lissajous Pattern
Lissajous position
Surround Phase
Surround Position
Surround type
Surround Blending
Turning audio meters on or off
Adjusting the position of the audio
meter on the screen
Set the transparency of the audio
meter background colour
Setting the audio meter marker line
Value
ON,OFF
Top Left, Top Right, Bottom Left,
Bottom Right
OFF,LOW,HIGH
ON,OFF
ON,OFF
Top Left, Top Right, Bottom Left,
Bottom Right
ON,OFF
Top Left, Top Right, Bottom Left,
Bottom Right
5.1,
OFF,LOW,HIGH
Turn on or off Lissajous figure
Set the position of the Lissajous
position on the screen
Turn surround Phase on or off
Adjusting the position of the surround
sound display on the screen
Selecting the type of surround sound
Set the transparency of the surround
sound background colour
Select the left channel
output channel
Select the right channel
output channel
Adjust audio volume
Adjust audio volume
Turn on/off Time code
Turn on/off H/V Delay
Channel 1~16
Channel 1~16
0~100
0~100
OFF, ON
OFF, ON
*3 Eye pattern
Only SDI1 supports eye diagrams.

*2. Left Channel/ Right Channel
Audio meter under SDI showing 16 channel audio meter
Audio meter under HDMI, menu shows 8 groups of channels
*3 H/V Delay
H/V Delay is not displayed on HDMI channel.
*1. Audio meter marker
Audio table display, display 16 channel audio table Type1: Only the audio table is
displayed Type2: Display audio decibels, audio alarm signal and left and right channel
options
9. Auto Calibration*1
Menu Item
Probe Select *2
Start Calibration*3
Measure*4
Menu Description
Select a probe to use
Select whether to start calibration
Test current color
Value
X-rite l1 Pro OEM, Jeti Specbos 1211
No/Yes
No/Yes
*1.Auto Calibration
The monitor has 3D LUT calibration software built-in, and supports the following color
sensor probe to directly plug into front USB port. When start calibration, the monitor will
generate standard colors and the color sensor will read the colors one by one and upload
result to the monitor by USB connection. The monitor will comparing the generated
colors and sensor read colors, to work out 3D LUT cube and calibrate itself automatically.
*2.Probe Select
This monitor supports the following probes models:
BRAND
X-rite
JETI
MODE
I1 Pro OEM(SWIT OEM)
Specbos 1211
*3.Start Calibration
Steps:
1、Put the monitor into a dark room. Switch on the monitor.
2、Connect the calibration instrument (compatible with x-rite and JETI color measuring
instruments) and monitor via USB. Before calibration, ensure that the monitor and the color
calibration instrument are in good condition and the monitor aging time reaches 30 minutes.
.eborp noitarbilac desu yltnerruc eht tceles dna ”tceleS eborP“ eht retnE、3
eht yalpsid lliw rotinom ehT .noitarbilac trats ot ”sey“ tceles dna ”noitarbilaC tratS“ eht retnE、4
prompt message and the color position prompt box. Put the sensitive part of the device in the
color position prompt box correctly. Note that when placing the calibration instrument; do not
squeeze the monitor’s LCD screen.
17
Audio alarm information
Left Channel:1 Green Right Channel:2 Red
Type 1 Type 2
M
T
U
E
M
T
U
E
M
T
U
E
M
T
U
E
M
T
U
E
M
T
U
E
U
N
L
O
C
K
E
D
U
N
L
O
C
K
E
D
U
N
L
O
C
K
E
D
U
N
L
O
C
K
E
D
U
N
L
O
C
K
E
D
U
N
L
O
C
K
E
D
U
N
L
O
C
K
E
D
U
N
L
O
C
K
E
D
1 2 3 4 5 6 7 8 9 10111213141516
-50
-20
-10
L -32DB 01CH R -13DB 02CH
-60
-40
-30

5、Select "yes" to begin auto calibration. The color calibration instrument will automatically
measure the color of the screen and correct the color of the screen. During this process,
it is necessary to observe the color calibration progress bar in the color correction prompt box.
6 、 Press "INFO" to terminate the color correction process at any time. When the prompt color calibration
progress reaches 100%, the whole automatic color calibration is completed. After automatic color
correction, press the "INFO" button to exit the menu and let the monitor enter the normal display mode.
7、After the automatic color correction, the display screen pops up “Before Calibration” and “After
Calibration”.
*4. Measure
The monitor has been calibrated in factory. And may need to be re-calibrated after a period of time.
Before re-calibrated, the measure function can check the current color to compare with the last time
calibrated color, to decide if the monitor needs to be re-calibrated. Connect with the sensor probe
and place the sensor probe onto the right position like calibration step. Enter “Auto Calibration” ‒
“Measure”.
18
Auto Calibration
Progress 23%
Please wait...
Select INFO to Cancel!
INFO:Quit
Auto Calibration
Please make sure the monitor is in
dark room,and the sensor probe is
put in the center marker and close
to the screen.
Select MENU to start!
MENU:OK INFO:Quit
Auto Calibration
Please make sure the monitor is in
dark room,and the sensor probe is
put in the center marker and close
to the screen.
Select MENU to start!
MENU:OK INFO:Quit
R
R75
Mg
Mg75
B
B75
Cy
Cy75
G
G75
YI
YI75
W
Delta = 0.9
Before Calibration After Calibration
R
R75
Mg
Mg75
B
B75
Cy
Cy75
G
G75
YI
YI75
W
Delta = 2.3
CIE and Delta E
before calibration
CIE and Delta E
after calibration
R
R75
Mg
Mg75
B
B75
Cy
Cy75
G
G75
YI
YI75
W
Delta = 0.9
Last Calibration
New Measured
R
R75
Mg
Mg75
B
B75
Cy
Cy75
G
G75
YI
YI75
W
Delta = 2.3
CIE and Delta E
from last calibration
CIE and Delta E
from new measured
The monitor will generate several
colors and finish measure within 30
seconds. And display the result as:

10. System— User profile saving, firmware update.
Menu Item
Key Lock *1
Recall Profile*2
Save Profile
Payload ID
Low Latency Mode
Green mode
Idle Duration
IP*3
Net Mask
Gateway
Port(1024~65535)
OSD TIME
Key Brightness
Language
System Reset
Update *4
Menu Description
Set lock key
Select make user mode current
Save the current state as a user setting
When turned on, Payload ID information conforming to
SMPTE ST 352 standard is automatically adapted
Open or close low latency mode
Set the display mode of green mode
Set how long it will be in the no-signal state and turn
on green mode
Set up the monitor IP address to achieve remote web
control
Set OSD display time
Set the brightness of the key lamp
Select Chinese or English language to display
Reset all Settings in the menu system
Set whether to upgrade firmware
Value
OFF, Full Lock
Factory,USER1,USER2,USER3,USER4
USER1,USER2,USER3,USER4
OFF, ON
OFF, ON
Black Backlight, Gray Backlight
30 Sec, 1 Hour, 2 Hours, 4 Hours, OFF
192.168.001.200
255.255.255.000
192.168.001.001
08080
5~180
OFF, Low, High
Chinese,English
No/Yes
No/Yes
*1.Key Lock
The “Menu/Enter” button can be operated when the button is locked. “Key Locked” will be displayed
on the screen when you press the Locked button or knob.
19
Key Locked
All

20
*2 . Recall Profile/ Save Profile
User Settings provide 4 menu Settings, that is, users can save the current monitor menu Settings as
one user Settings (USER1~USER4) according to usage habits. Then, when switching menu Settings,
just select the corresponding "USER1~USER4" through the “Recall Profile” item to display the corre-
sponding menu Settings.Example:By adjusting the parameters of the color temperature of 2200K,
open the necessary auxiliary functions (such as: histogram), set the function key to the desired menu
(such as F1 is set to "Blue Only"), and so on, the monitor Menu Settings can be "USER Settings" save as
"USER" 1, rotating the “Menu/Enter” choose to load the USER Settings "set to the current" USER 1
"mode, the monitor Menu item value will show" USER 1 "mode to save Menu.
*3 . IP control
Connect the monitor to the LAN through an ETHERNET interface, and the Monitor can be controlled
by web page.
Fig1:IP Address setting Fig2:Web page
Monitor IP address Monitor port address
Pin No
1
2
3
4
5
6
7
8
Pin Name
TX+
TX-
RX+
RX-
Enter Menu- System ‒ IP/Net Mask/Gateway/Port to set the monitor address. Set the computer
Ethernet IP addresses at the same LAN environment as the Monitor. Launch any of a web
browser on the computer, and enter URL: Monitor IP+ Port (Example: 192.168.1.99.8080). The
web server control page will be displayed.
This manual suits for next models
3
Other SWIT Monitor manuals