manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Symmons
  6. •
  7. Plumbing Product
  8. •
  9. Symmons Symmetrix S-20-IPS Quick guide

Symmons Symmetrix S-20-IPS Quick guide

This manual suits for next models

2

Other Symmons Plumbing Product manuals

Symmons SK-6600 Manual

Symmons

Symmons SK-6600 Manual

Symmons Elm SRT-5570 Reference guide

Symmons

Symmons Elm SRT-5570 Reference guide

Symmons Symmetrix S202PP Manual

Symmons

Symmons Symmetrix S202PP Manual

Symmons SLW-5512-1.5 User manual

Symmons

Symmons SLW-5512-1.5 User manual

Symmons 3DIV-BODY Manual

Symmons

Symmons 3DIV-BODY Manual

Symmons Symmetrix S-250 Series Quick guide

Symmons

Symmons Symmetrix S-250 Series Quick guide

Symmons Carrington Trim Series Installation instructions

Symmons

Symmons Carrington Trim Series Installation instructions

Symmons SLS-5512 Series User manual

Symmons

Symmons SLS-5512 Series User manual

Symmons Allura 4700-TRM Installation instructions

Symmons

Symmons Allura 4700-TRM Installation instructions

Symmons Identity SLC6712PP Manual

Symmons

Symmons Identity SLC6712PP Manual

Symmons Vella S-2610 Series Quick guide

Symmons

Symmons Vella S-2610 Series Quick guide

Symmons Carrington Series Installation instructions

Symmons

Symmons Carrington Series Installation instructions

Symmons Duro 361TS Series Manual

Symmons

Symmons Duro 361TS Series Manual

Symmons Unity SK6600PO Manual

Symmons

Symmons Unity SK6600PO Manual

Symmons Sereno 4300-TRM Manual

Symmons

Symmons Sereno 4300-TRM Manual

Symmons Origins 9600-P Manual

Symmons

Symmons Origins 9600-P Manual

Symmons Carrington 442HS User manual

Symmons

Symmons Carrington 442HS User manual

Symmons Oxford Trim Series Installation instructions

Symmons

Symmons Oxford Trim Series Installation instructions

Symmons Unity Trim Series Installation instructions

Symmons

Symmons Unity Trim Series Installation instructions

Symmons Winslet S-5100-TRM Installation instructions

Symmons

Symmons Winslet S-5100-TRM Installation instructions

Symmons TEMPTROL II Operation manual

Symmons

Symmons TEMPTROL II Operation manual

Symmons SLC72121.2 Manual

Symmons

Symmons SLC72121.2 Manual

Symmons Ballina 522TS Manual

Symmons

Symmons Ballina 522TS Manual

Symmons Carrington SRT-4470 Quick guide

Symmons

Symmons Carrington SRT-4470 Quick guide

Popular Plumbing Product manuals by other brands

Moen SANI-STREAM 8797 manual

Moen

Moen SANI-STREAM 8797 manual

Grohe Allure Brilliant 19 784 manual

Grohe

Grohe Allure Brilliant 19 784 manual

Cistermiser Easyflush EVO 1.5 manual

Cistermiser

Cistermiser Easyflush EVO 1.5 manual

Kohler Triton Rite-Temp K-T6910-2A installation guide

Kohler

Kohler Triton Rite-Temp K-T6910-2A installation guide

BEMIS FNOTAB100 Installation instruction

BEMIS

BEMIS FNOTAB100 Installation instruction

Hans Grohe ShowerTablet Select 700 13184000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe ShowerTablet Select 700 13184000 Instructions for use/assembly instructions

Akw Stone Wash Basin Installation instructions manual

Akw

Akw Stone Wash Basin Installation instructions manual

Enlighten Sauna Rustic-4 user manual

Enlighten Sauna

Enlighten Sauna Rustic-4 user manual

Moen ShowHouse S244 Series quick start guide

Moen

Moen ShowHouse S244 Series quick start guide

Sanela SLWN 08 Mounting instructions

Sanela

Sanela SLWN 08 Mounting instructions

Franke 7612982239618 operating instructions

Franke

Franke 7612982239618 operating instructions

Heritage Bathrooms Granley Deco PGDW02 Fitting Instructions & Contents List

Heritage Bathrooms

Heritage Bathrooms Granley Deco PGDW02 Fitting Instructions & Contents List

Tres TOUCH-TRES 1.61.445 instructions

Tres

Tres TOUCH-TRES 1.61.445 instructions

STIEBEL ELTRON WS-1 Operation and installation

STIEBEL ELTRON

STIEBEL ELTRON WS-1 Operation and installation

Miomare HG00383A manual

Miomare

Miomare HG00383A manual

BELLOSTA revivre 6521/CR1 quick start guide

BELLOSTA

BELLOSTA revivre 6521/CR1 quick start guide

American Standard Heritage Amarilis 7298.229 parts list

American Standard

American Standard Heritage Amarilis 7298.229 parts list

BorMann Elite BTW5024 quick start guide

BorMann

BorMann Elite BTW5024 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installation
Caution: Be sure to turn off hot and cold water supplies
before installing or servicing faucet.
1. Loosely install the anchor bar (KN-23), spacer (KN-26) and
nut (L-36) on the mounting bolts and place gasket on base
of faucet. Push faucet supplies and anchor bolt/spacer/nut
assemblies with gasket through holes in sink. Secure faucet
to sink by tightening nuts from underside. (If sink or coun-
ter surface is uneven, use putty or sealant to make proper
seal under base.)
2. Connect hot supply to le tube and cold supply to right
tube using appropriate connectors.
3. Pop-up drain installation:
a) Remove pop-up plug, tail piece and ange from the drain
body. Make sure that locknut is threaded all the way
down onto the body with at friction washer in middle
and beveled washer on top.
b) Apply plumbers putty or sealant to bottom of ange.
c) Install drain body through drain opening in lavatory
and screw ange onto the drain body making sure that
the threads are completely engaged for proper sealing
and strength of the connection. Apply joint compound
to all threaded parts to insure proper seal. Apply putty or
teon tape to tail piece before attaching to drain body.
d) Tighten locknut to compress the beveled ange evenly
across the bottom of the drain opening taking care not to
over tighten the locknut, causing damage to the lavatory.
e) Remove one of two ball washers from inside the
threaded cavity. Insert pop-up plug and pivot rod into
body. Add one ball washer (the second ball washer
should remain inside the body) to the outside of the ball.
Tighten the retaining nut until the ball is seated on the
internal and external ball washers.
Note: e pop-up plug can be installed either in the remov-
able or non-removable position, depending on the location
of the hole located in the guide at the bottom of the plug.
f) Slide the pivot rod through one side of the spring clip,
then the appropriate adjustment hole and then other
side of the spring clip.
g) Insert li rod through faucet housing and the top of the
li strap and secure it in place by tightening the screw.
Note: To ensure proper operation of li rod and pop-
up, some adjustment of the linkage may be required.
ere are two possible adjustment points: 1) li strap to
li rod and 2) li strap to pivot rod.
4. It is very important to thoroughly ush the supply lines to
prevent foreign matter, i.e. copper chips, sand, stones, etc.
from damaging the sealing surfaces of cartridge.
Remove aerator and turn valve handle on to full cold posi-
tion, open cold supply. Without closing, turn handle to full
hot and open hot supply. Let water run in hot only and cold
only positions long enough to ush supply lines thoroughly.
Shut o faucet and replace aerator. Check for leaks.
5. e handle limit stop can be
set to limit handle turn to
the hot position. e limit
mechanism is factory set to
allow full handle travel. To
adjust the limit stop, turn
handle to the full hot position
and li handle to open faucet
approximately half way to
obtain a smooth ow for
correct initial temperature
measurement.
6. If when faucet is on and in
full hot position and water is
too hot, remove plug button
(KN-157), loosen set screw (L-
22) and remove handle (KN-3RB, KN-3BRB or LN-135).
Li limit stop ring using a small at head screw driver and
rotate counter clockwise to lower temperature. If water is
not hot enough, rotate clockwise (See Figure 1 on reverse
side). Aer correct temperature is achieved, reattach
handle, reversing procedure above.
Replacing cartridge (KN-4)
1. Remove plug button (KN-157), loosen set screw (L-22) and
remove handle (KN-3RB, KN-3BRB or LN-135).
2. Engage tabs in cartridge wrench (LN-34) with slots in com-
pression ring (KN-2) and use screwdriver in wrench holes or
pliers on wrench and turn counter clockwise until compres-
sion ring engages with cap (LN-8). Continue turning counter
clockwise so that cap/ring assembly is removed from the body
(LN-371). Remove cartridge and three ring seal (KN-4).
3. Install new cartridge while taking care to maintain position
of the three ring seal at the base of the cartridge. Match
posts in base of cartridge with alignment holes in valve
body during assembly.
4. Reassemble faucet in reverse fashion. read cap onto body
rmly by hand. Do not use a wrench which may damage
the nish. Tighten compression ring (KN-2) nger tight
using the wrench (LN-34) then 1/4 to 1/2 turn further.
5. Set hot water limit stop in accordance with installation step
5 above.
Lavatory Faucet S-20 Series
Installation and Service Instructions
Symmetrix®
Stop limit adjust
For California Residents
WARNING: is product contains chemicals known to
the State of California to cause cancer, birth defects, or
other reproductive harm.
KN-2 Compression ring
KN-3RB* Solid handle
KN-3BRB* Loop handle
KN-4 Cartridge
KN-23 Anchor bar (2)
KN-26 Mounting spacer (2)
KN-157 Plug button
LN-8* Valve cap
LN-11* Screw (2)
LN-15* Aerator without removal key
LN-34 Cartridge wrench
LN-135 6” lever handle with red/blue indicators
LN-363* Undercover plate
LN-370 Mounting gasket
LN-371 Cartridge housing assembly
L-22 Set screw
L-36 Mounting nut (2)
L-42 Nut (2)
RL-154* Pop-up drain assembly (complete)
P-26 Grid drain assembly (complete)
For Decorative Finish Faucets add sufx to
parts marked with an asterisk as follows:
Sufx -STN Radiance®Satin nish
KN-3BRB
RL-154
P-26
LN-135
Vandal resistant
aerator
removal tool
Standard aerator
optional IPS
connections
shown
LN-370
L-42
LN-11
LN-363
LN-371
KN-4
KN-2
LN-8
KN-157
L-22
KN-3RB LN-34
Removal tool part number, LL-60K
2.2 gpm (8.3L/min)
1.5 gpm (5.7L/min)
1.0 gpm (3.8L/min)
0.5 gpm (1.9L/min)
LN-15*
FLR-110-1.5*
FLR-110-1.0*
----
LN-101*
RL-288
(non-aerated)
RL-288-VP-1.0
(non-aerated)
LN-100*
Standard
Aerators
Vandal Resistant
with removal tool
Part Number
Aerator
(ow regulator)
Reference
chart
Parts Assembly Symmetrix Lavatory Faucet, S-20 Series
Dimensions Symmetrix Lavatory Faucet, S-20-2
Note: Dimensions subject to change without notice.
Symmons Industries, Inc. 31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-962
Copyright © 2017 Symmons Industries, Inc. ■symmons.com ■[email protected] ■ ZV-329 REV G ■020117