manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Symmons
  6. •
  7. Plumbing Product
  8. •
  9. Symmons Temptrol 46-1-BODY Reference guide

Symmons Temptrol 46-1-BODY Reference guide

1 2 3 4
Pipe
Sealant
Plumbers
Putty
Tools & Materials  Need Help?
Contact Symmons customer service at
P: (800) 796-6667, F: (781) 848-2250
[email protected]
Mon - Fri 7:30 am - 7:00 pm EST
Please check Symmons website
for technical help, the latest product
information and warranty policy.
www.symmons.com/service
Model Number
46-1-BODY
Temptrol 3 port pressure balancing
Shower valve body (46-1X-BODY
with built-in service stops)
Temptrol®
Figure 1 Mounting plate
(valve without IPS ports shown)
p/n T-176 p/n T-177
Protective shield
When mounting plate is used,
then shield is optional for
protecting end of valve during
installation.
"snap on-off"
wall cutout hole size
3-1/2" (89 mm) min
4" (102 mm) max
nished
wall
Ensure valve’s
mounting plate
is ush against
inner wall
Walls for using T-177 valve mounting plate
 Fiberglass or acrylic walls (required)
 Plaster or other type walls (optional)
1/16" (2 mm) min 1/2" (13 mm) max
wall cutout hole size
3-1/2" (89 mm) min
4" (102 mm) max
Finished wall must be
ush with back side of
protective shield surface
nished wall
Dry wall, plaster or other type wall
1/2" (13 mm) or greater
Protective shield
"snap on-off"
(required when
valve mounting
plate is not used)
Reference rough-in
dimensional
drawing on page 2
Figure 2 Mounting valve (valve without IPS ports shown)
Rough-in Installation
Installing control valve, piping & fittings
Reference rough-in dimension illustration
on page 2 as required.
1) Determine wall thickness
■
Determine type of wall and wall
thickness where valve will be mounted.
■ Consider whether to use mounting plate
by reviewing gure 2 below.
■ Skip ahead to Step 3 if mounting
plate will not be used.
2) Attach mounting plate to valve
Seat mounting plate against valve
assembly as illustrated in gure 1.
3) Attach protective shield
■ Reference gure 2 to determine
whether shield is required.
■ Attach plastic protective shield by
snap tting over end of valve spindle.
4) Install piping, fittings and
control valve
Piping and ttings not supplied
■ Control Valve
Install valve through cutout hole in
wall as specied in gure 2 below and
dimension illustration on page 2.
■ Showerhead (S on valve)
Pipe from outlet port on valve marked S
to showerhead mounting arm location.
■ Hot & Cold Supply (H & C)
Pipe hot water supply to valve input
marked Hand cold water supply to
valve input marked C.
For California Residents
WARNING: This product contains
chemicals known to the State of
California to cause cancer, birth defects,
or other reproductive harm.
3 Port Pressure Balancing Shower Valve
46-1-BODY, 46-1X-BODY
Installation Brief
Page 2
■ Tighten packing nut for positive
frictional resistance as handle is
rotated from shuto position across
adjustment range.
7) Flush system and check for leaks
■ Turn valve to the warm position and
run for a few minutes.
■ If system is dirty, remove valve spindle
in center of valve to ensure proper
ushing. (See service instructions.)
Figure 3 Valve adjustments
wall
Temp Limit
stop screw
packing nut
control
spindle
stem
Important! Do not substitute
Tub Spout with restrictive
ttings such as PEX, CPVC or
outlet accessories such as a ledge
spout, hose and spray
that would
subject the valve excessive internal back
pressure, otherwise operation will be
compromised.
5) Remove protective shield
If attached in Step 3, then remove shield
snap tted over the end of valve spindle
once valve is securely installed and wall
nish work has been completed.
6) Adjust valve packing nut
Reference gure 3
■ Turn hot & cold supplies on.
Valve will not operate unless both hot
and cold water supply pressures are on.
■ Place handle over control spindle stem.
■ Check for leaks around valve
assembly and all pipe ttings.
8) Set Temp Limit stop screw
Reference gure 3
e limit stop screw limits valve handle
from being turned to maximum
position resulting in excessive hot
water discharge temperatures.
Warning:
Failure to adjust
limit stop screw properly may
result in serious scalding.
■ Place handle on control spindle and open
valve to maximum desired temperature.
■ Turn limit stop screw clockwise until
it seats.
Note:
Do not install positive shut-o
devices on control valve outlet or devices that
do not allow the valve to ow at least 1.5 gpm.
shower supply
showerhead supply
3" (76 mm)
Notes:
(1) Dimensions subject to
change without notice.
(2) Valve spindle can be further
extended through thicker
walls when mounting plate
is not used.
(3) Dimensions apply when
T-177 mounting plate is
not used.
(4) Use alternate dimension
gures when installing
escutcheon trim listed in
table below.
Temptrol
mixing valve
Shower Valve
46-1-BODY
46-1X-BODY
2-3/8" ±1/2"
(60 mm ±13 mm)
pipe centerline
to nished wall
See Notes 3 & 4
Trim Series Pipe centerline to nished wall
Oxford 2" (51 mm)
± 1/4" (±6 mm)
Allura*2" (51 mm)
± 1/2" (±13 mm)
Carrington 2" (51 mm)
± 1/2" (±13 mm)
Canterbury 2" (51 mm)
± 1/2" (±13 mm)
Temp Com 2" (51 mm)
± 1/2" (±13 mm)
*
with standard LHM handle only
approx.
45"
(1143 mm)
approx.
42"
(1067 mm)
nished wall
Floor
wall
Rough-in Dimensions Temptrol 3 Port Shower Valve Body, 46-1-BODY, 46-1X-BODY
Page 3
TEMP LIMIT
stop adjust
Control spindle
assy. (TA-10)
Hot seat
removal tool
(T-35A)
Cold seat
removal tool
(T-35B)
Hot & cold seat
repair kit (TA-4)
Service stop
Retainer
wrench, (T-55C)
Service stop
and retainer
kit (T-52)
Service stop retainer
Spindle cap assy.
& control spindle
(TA-10/12)
Temptrol
Control
Valve
HOT
supply
inlet
Shower supply oulet
COLD supply inlet
Cap washer
repair kit
(T-16)
Cap assembly
(T-12A)
cap gasket
cap
limit stop screw
o-ring
washer
packing
packing nut
hot washer screw
hot washer
cold washer retainer
cold washer
cap gasket
Control spindle
washer repair kit
(TA-9)
hot
seat
Retainer
cold
seat
Retainer
Parts Assembly Temptrol 3 Port Shower Valve Body, 46-1-BODY, 46-1X-BODY
Temptrol Valve Replacement Parts and Optional Tools
Valve Body Type
Description
46-1-BODY 46-1X-BODY
TA-4 HOT & COLD seat repair kit
...........
(optional tool p/n T-35A/B)
TA-9 Control spindle washer repair kit
TA-10 Control spindle
...........
(includes p/n TA-9 & T-16 components)
T-12A Cap assembly
T-16 Cap washer repair kit
T-35A/B HOT seat removal tool, T-35A &COLD seat removal tool, T-35B
T-55C Service stop spindle, retainer & removal tool
T-108 Reverse seat & tool kit (valve HOT & COLD supply inputs are reversed)
Symmons
Part
Number
T-52
√
√
√
√
√
√
√
√
√Service stop spindle & retainer
√
√
√
√
√
√
√
■ If piston appears restricted then do the
following:
(1) Tap the handle or stem end of the
spindle against a solid object to free
the piston.
(2) Try soaking in household vinegar
and repeat step (1).
■ If unable to free piston, replace control
spindle, p/n TA-10.
Important: Do not attempt
removal of the piston.
Valve re-assembly
Reassemble by reversing above
procedures.
Aer the control spindle assembly (TA-10)
is threaded back into the spindle cap
assembly (T-12A) ensure control spindle
is rotated 1/2 turn clockwise from its
maximum counter clockwise rotational
position. Failure to do this will damage
assembly.
Service Instructions
Removing control spindle assembly
(Ref. parts assembly figure)
■ Shut o water supply to valve and
remove control valve handle and
dome cover.
■ Remove escutcheon plate by rst
removing escutcheon screws.
■ Turn valve’s control spindle to half
way position between minimum and
maximum rotation.
Important: Failure to
do this can damage
control spindle assembly.
■ Unscrew both spindle cap and control
spindle assembly.
Hot/Cold seat repair kit
Order p/n TA-4, T-35A and T-35B.
Installation requires both hot & cold removal
tools, p/n T-35A & T-35B.
■ Remove control spindle assembly.
■ Remove both seats with removal
tools.
■ Replace both seats even if only one
appears worn.
■ Install and tighten both seats to 15 foot
pounds of torque.
Control spindle washer repair kit
Order p/n TA-9.
■ Remove control spindle assembly.
■ Remove cold washer by holding spindle
using valve handle and unscrew cold
washer retainer using channel lock
pliers.
■ Remove hot washer by removing hot
washer screw.
Checking water pressure
balancing piston
e perforated end of the control spindle
assembly houses the water pressure-
balancing piston which is the heart of the
valve.
■ Remove control spindle assembly.
■ Shake spindle assembly and listen for
clicking noise. Piston should be free to slide
back and forth the full length of its travel.
Trouble Shooting Chart
Problem Cause Solution
Valve will not pass water. Both hot and cold water supplies are
not turned on.
Turn on both supplies. Valve will not operate
unless both hot and cold water pressure is on.
Valve leaks when shut o. Hot and cold washers are worn or
foreign matter (dirt, chips) is lodged
between washers and seat surfaces.
1) Replace washers using control spindle washer
repair kit, p/n TA-9.
2) Replace hot & cold seats using hot/cold seat
repair kit, p/n TA-4.
Temperature control handle is turned
from cold to hot (or hot back to cold)
and volume from spout or head is not
constant.
Pressure-balancing piston housed in
spindle assembly is restricted from
free movement by foreign matter.
1) Open valve halfway, remove handle and tap
spindle with plastic hammer.
2) Check water pressure balancing piston in
control spindle. See service instructions.
3) Replace control spindle, p/n TA-10.
Valve delivers sucient quantity of cold,
but little hot, or the reverse.
Same as above Same as above
Temperature varies without moving
handle.
Same as above Same as above
Valve delivery temperature reduces
gradually during use; handle must be
turned to hotter positions to maintain
constant temperature.
Overdraw on hot water supply (i.e.
running out of hot water).
Reduce maximum ow by using volume
control adjustment on valve or showerhead.
is will allow longer period of use before
overdrawing hot water supply.
Valve delivers hot water when initially
opened. Water turns colder as handle is
rotated in a counter-clockwise direction
toward the hot position.
Valve is piped incorrectly (i.e. the hot
supply is piped to the valve’s cold inlet
and the cold supply is piped to the hot
inlet.)
If piping is accessible, correct connections to
the valve. If piping is not accessible, order
a reverse seat and tool kit, p/n T-108. Older
installations may also require replacing the
hot seat, hot/cold seat repair kit, p/n TA-4.
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2017 Symmons Industries, Inc. ■symmons.com ■[email protected] ■ ZV-3236 REV 0 ■041317

This manual suits for next models

1

Other Symmons Plumbing Product manuals

Symmons Sereno Trim Series Installation instructions

Symmons

Symmons Sereno Trim Series Installation instructions

Symmons Sereno SPP-4310-PD User manual

Symmons

Symmons Sereno SPP-4310-PD User manual

Symmons Sereno SK2302PD Manual

Symmons

Symmons Sereno SK2302PD Manual

Symmons Elm 552SH Manual

Symmons

Symmons Elm 552SH Manual

Symmons S-4700-TRM Manual

Symmons

Symmons S-4700-TRM Manual

Symmons Allura Series Quick guide

Symmons

Symmons Allura Series Quick guide

Symmons Duro 361TS Manual

Symmons

Symmons Duro 361TS Manual

Symmons Ballina Trim Series Manual

Symmons

Symmons Ballina Trim Series Manual

Symmons SLW-5512-1.5 User manual

Symmons

Symmons SLW-5512-1.5 User manual

Symmons Allura 4700-TRM Installation instructions

Symmons

Symmons Allura 4700-TRM Installation instructions

Symmons Dia SLS-3512 Series Reference guide

Symmons

Symmons Dia SLS-3512 Series Reference guide

Symmons Carrington SRT-4472 Reference guide

Symmons

Symmons Carrington SRT-4472 Reference guide

Symmons Unity 66-2DIV Manual

Symmons

Symmons Unity 66-2DIV Manual

Symmons Symmetrix S240 Manual

Symmons

Symmons Symmetrix S240 Manual

Symmons Origins SLC9612PP Manual

Symmons

Symmons Origins SLC9612PP Manual

Symmons Dia SLC-3512-1.5 Manual

Symmons

Symmons Dia SLC-3512-1.5 Manual

Symmons Origins ActivSense S6960B User manual

Symmons

Symmons Origins ActivSense S6960B User manual

Symmons Dia ADA Series Troubleshooting guide

Symmons

Symmons Dia ADA Series Troubleshooting guide

Symmons Unity S-6600-OP Manual

Symmons

Symmons Unity S-6600-OP Manual

Symmons Origins Trim Series Installation instructions

Symmons

Symmons Origins Trim Series Installation instructions

Symmons Dia S-3504-H321-V-CYL-B-TRM Manual

Symmons

Symmons Dia S-3504-H321-V-CYL-B-TRM Manual

Symmons Unity SK6600PO Manual

Symmons

Symmons Unity SK6600PO Manual

Symmons S-71 Series User manual

Symmons

Symmons S-71 Series User manual

Symmons SK-6600 Manual

Symmons

Symmons SK-6600 Manual

Popular Plumbing Product manuals by other brands

Toto STANDARD T205 quick start guide

Toto

Toto STANDARD T205 quick start guide

Sterling Plumbing Seated Shower Receptor and Wall Surrounds with Backer Boards... Specification sheet

Sterling Plumbing

Sterling Plumbing Seated Shower Receptor and Wall Surrounds with Backer Boards... Specification sheet

Peerless Faucet P183510LF quick start guide

Peerless Faucet

Peerless Faucet P183510LF quick start guide

RIDGID Kollmann KJ-1590 operating instructions

RIDGID

RIDGID Kollmann KJ-1590 operating instructions

SUMERAIN S1248CW installation guide

SUMERAIN

SUMERAIN S1248CW installation guide

American Standard Hamilton 4048S Specification sheet

American Standard

American Standard Hamilton 4048S Specification sheet

VIDIMA SEVA NEW B 3136 Series manual

VIDIMA

VIDIMA SEVA NEW B 3136 Series manual

UBERHAUS DESIGN 70115075 quick start guide

UBERHAUS DESIGN

UBERHAUS DESIGN 70115075 quick start guide

Triton ASANA MINI Instruction book

Triton

Triton ASANA MINI Instruction book

Kohler BEAM K-30939T installation instructions

Kohler

Kohler BEAM K-30939T installation instructions

IKEA TUNASJON manual

IKEA

IKEA TUNASJON manual

Mankenberg KA Original operating manual

Mankenberg

Mankenberg KA Original operating manual

ProFlo PFWSCM1M1087 installation instructions

ProFlo

ProFlo PFWSCM1M1087 installation instructions

Ideal-Standard iLife 2 T4887EO Manual for Use, Installation and Maintenance

Ideal-Standard

Ideal-Standard iLife 2 T4887EO Manual for Use, Installation and Maintenance

Zenith Surgeon 42226NZ Installation and Operating Procedures

Zenith

Zenith Surgeon 42226NZ Installation and Operating Procedures

BELLOSTA brunsin 5701/4 Installation instruction

BELLOSTA

BELLOSTA brunsin 5701/4 Installation instruction

Panasonic DH-4NS3 operating instructions

Panasonic

Panasonic DH-4NS3 operating instructions

HydroCare HC44 installation instructions

HydroCare

HydroCare HC44 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.