5
7. Click “Read TAG” to receive TAG information.
8. Adjust RSSI level (0~250) to filter TAG which have low RSSI signal in reader.
(This function was available in version 1.30 or above.)
Ex. Set RSSI Level to 120, Reader will receive tag which RSSI are stronger than
120.
9. Set Gain (1~7) to control reader’s read range.
Level 7 is the max range (default setting), Level 1 is the shortest read range.
10. Set Exciter ID (This function was available in version 2.03 or above.) :
This parameter should use with SYRIS exciter, default values are “0000” means
disable. If this function enable, reader will only receive tag’s signal which include
set exciter ID.
11. Reader Reset: Reset online reader. Reader will warm restart.
Factory Default: All setting will set factory default.