Category
Symptoms of major
errors and
Trouble shooting
KD200
Service Manual
page
Page 7/10
(1)When the ON/TARE button is pressed ,the scale does not turn on .
Confirming Item Confirming content Repairing method
The battery direction Checking the battery
direction Insert battries in position paying
Colose attention to (+-)direction
The battery voltage 4 batteries have a voltage
higher than 4V If the voltage lower than 4V please
Exchange 4 batteries simultaneously
Wires and battery
Contact plate solder According to item 1,2,3 on
page 9 and to item 1,2,3,4,5
6,7 on page 10.
Arrange the connection in correct
order
Plastic housing Checking the switch plastic
is deformed Exchange the cover assembly If it
is deformed
PCB Exchange the circuit-board
assembly No problem ,Can adjust the
contrast.
(2)[0]or weight values are unstable
Confirming Item Confirming content Repairing method
Temperature range Ensure proper temperature
range Maintain a constant temperature for
1~ 2 hours before use
Effecting as vibration Checking excessive vibration Stop vibration or move to a place
with little or no vibration
Effecting as wind Checking excessive wind Stop wind or move to a place
with little or no wind
Solder According to item 4,5 on
page 9 and to item 8,9 on
page 10
Arrange the connection in correct
order
Screw Checking the conation screw
M4×16 Double shear strength must be more
than 0.6N·m
Mixing sundries According to item 28,29 on
page 3 Removing sundries
PCB Exchange new PCB Adjust again
(3) [0]doesn’t exchange after the weight is measured
Confirming Item Confirming content Repairing method
Solder According to item 4,5 on
page 9 and to item 8,9 on
page 10
Arrange the connection in correct
order
PCB Exchange new PCB Adjust again