Xpress Flex device (L-XF011)
Dipper spoon w/ paddle handle (#2235)
Pipet (#4030)
Cap for dipping vial (3) (#6825)
Counter mat (#6849)
5 mL Syringe (3) (#6858)
Test strip clips (3) (#9001)
Test strip loader (#9002)
Water sample dipping vials (3) (#9003)
Iron Prep reagent (R-9103)
Phosphate Prep reagent (R-9112-C)
Flex Strips:
Flex 1 (S-1361)
Flex 2 (S-1362)
Flex 3 (S-1363)
Flex 4 (S-1364)
COMPONENTS LIST
L-XF011
6849
9001
9002
9003
S-1362 S-1361
S-1363
S-1364
R-9103
4030
2235
6858
6825 R-9112-C

1. Unpack components from the box (see components list to the left).
2. You will nd four perforated holes on the counter mat. These align with the suction cups on the bottom of the Xpress Flex
device. Pop out the excess material and place the mat on the counter.
3. Place Xpress Flex device on the counter mat aligning suction cups. Press down on device.
4. Place Flex Strips and prep reagents in designated holders on top of the Xpress Flex device.
5. Go to retail.sureTREAT.com. If you already have a sureTREAT account, please log in and proceed to step 6. If you do not have
a sureTREAT account, please see the attached instructions to create one. (Be sure you are using the most up to date version of
Windows (Windows 10) before proceeding.)
6. After logging into retail.sureTREAT.com, download the XFConnect software. You can nd this by choosing Support on the
bottom navigation bar and then selecting Download XFConnect. Run the XF Connect Installer.
7. Ensure that the XFConnect software is running. Connect the USB cord from the Xpress Flex device to your computer.
8. Now that your system is set up, please watch this short video to learn about the Xpress Flex testing process:
taylortechnologies.com/en/content/xpress-ex-support
9. You are ready to start Flexing! Thank you for trusting Taylor Technologies with your testing needs.
Your Xpress Flex device will be automatically registered for warranty when you perform your rst water test.
QUICK START INSTRUCTIONS
Contact us at www.TaylorTechnologies.com or call 800-TEST KIT (837-8548) if you have any questions or feedback.

1
Thank you for choosing Xpress Flex, the next evolution of in-store water testing.
Xpress Flex is a cutting-edge testing system from the most trusted name in water testing: Taylor Technologies.
The Xpress Flex testing system consists of several components:
∙Xpress Flex device ∙Test Strip Loader
∙Flex Strips ∙Test Strip Clips (3)
∙Test prep reagents for iron and phosphate ∙5 mL syringe (3)
∙Water sample vials (3) ∙Pipet (use with R-9112-C prep reagent)
At the core of the testing system is the Xpress Flex device.This is an advanced test strip reader that utilizes sophisticated
technology to provide high-quality test results.
Xpress Flex strips are specifically engineered for use with the Xpress Flex device.
There are four test strips that can be used with Xpress Flex:
Flex 1 (S-1361) – 50 count: tests iron (use with R-9103 prep reagent)
Flex 2 (S-1362) – 50 count: tests salt, borate, and copper
Flex 3 (S-1363) – 100 count: tests free chlorine, total chlorine/total bromine, pH, total alkalinity,
total hardness, and cyanuric acid
Flex 4 (S-1364) – 50 count: tests phosphate (use with R-9112-C prep reagent)
XPRESS FLEX INSTRUCTIONS

2
Xpress Flex gives you the freedom to use only the strips you need. You can run any combination of strips, depending
on the results you are targeting. For example, iron may not be a common concern in your area, so the Flex 1 strip would
mostly be used to troubleshoot.
Next, let’s review performing a water test with Xpress Flex.This testing process was designed with you, the tester, in
mind.
Xpress Flex testing is performed at retail.sureTREAT.com
Sample prep:
1) Rinse water sample dipping vial with water to be tested.
2) Pour your sample water into the center chamber (fill to the top) of the water sample dipping vial.
3) If you are performing iron and/or phosphate testing, prep reagents are used with both tests.
The prep reagents ensure the highest level of accuracy for these tests.
Pro tip: Add the prep reagents to the empty chambers so that the addition of the water helps mix the sample.
a. For Iron Prep, add one level scoop of R-9103 to chamber 1.
b. For Phosphate Prep, use pipet to add 0.5 mL of R-9112-C to chamber 4.
c. Use the syringe to measure out the 5 mL of sample water from the center chamber
and add to the iron chamber. Repeat for the phosphate chamber.
3) Cap the center chamber and swirl to mix prep reagents.

3
The Test Strip Clip and Test Strip Loader are color-coded and labeled to match with corresponding strips to ensure proper
readings.
The strip loader makes adding strips simple, and it ensures the strips are aligned for accuracy.
Test: 1) Place the desired strip(s) onto the appropriate slots on the strip loader and use the strip clip to pick them up.
2) Select “Start Test” in the sureTREAT software. sureTREAT will provide timers on the screen, as well
as audio cues if you have speakers.
3) Dip the test strips into the vial for 2 seconds noting the correct orientation of test strips to the vial, remove,
and place the strip clip onto the shuttle. Press the shuttle into the device.
4) After one minute of testing, your results are ready.
Pro Tip: If you have multiple samples to be tested, this is great time to start the process for your next test.
Pro Tips for handling test strips:
∙Be sure you have dry hands before opening the test strip bottle.
∙Always handle strips from the bottom to avoid contact with the test pads.
∙Keep lid securely closed after removing a strip to prevent moisture from entering the bottle.
You will notice that the Flex 2 strip is packaged in an individually foil-wrapped sleeve.This packaging helps protect the
strip from sunlight which can degrade the salt test pad.
5) Empty and rinse water sample dipping vial after each test.
Pro Tip: For best results, pour used sample water out of the vial by holding the vial horizontally versus vertically. The iron
and phosphate test prep reagents can cause interference if they enter and contaminate the center chamber.

4
Xpress Flex is uniquely calibrated for each lot of Flex Strips. This calibration ensures the highest level of accuracy.
To match the lot of your Flex strips in the sureTREAT software, follow these steps.
The lot code is the last three digits stamped on the bottom of your Flex Strip bottle.This code will be an
alpha character followed by two numbers. For example,A11.
In the sureTREAT software, you will see the current setting for your Flex Strip lot code on the Flex Strip Status screen
when performing water tests with Xpress Flex.To change the code, click edit and select the proper code for each
Flex Strip from the options on the screen. Click update when you complete.
Thank you for choosing Xpress Flex for your in-store testing needs.
We value the trust you have placed in Taylor, and we trust that Xpress Flex will help you confidently meet
the needs of your customers.
Now, let’s start Flexing!
Taylor’s technical support is available for additional questions, feedback, and product support.
You can reach us at www.TaylorXpressFlex.com or by calling 1-877-TEST KIT (837-8548).

#5010
rev. B
11/08/21
This manual suits for next models
1
Table of contents
Other Taylor Test Equipment manuals
Popular Test Equipment manuals by other brands

DeFelsko
DeFelsko PosiTest DT instruction manual

Greiner Vibrograf
Greiner Vibrograf Compact 900 user manual

Fluke
Fluke 5520A Service Operator's manual

Badger Meter
Badger Meter Flo-tech PFM Series Installation & operation manual

EUTECH INSTRUMENTS
EUTECH INSTRUMENTS ECOTESTR EC HIGH instruction manual

Tempo Fitness
Tempo Fitness PE2003 instruction manual