Tecnoautomazione T182A User manual

RC1 RC2
EXTERNAL
RECEIVER
RC2
+5
GND
R1
R2
R3
R4
S1
S2
S3
STATUS
REMOTE
OUT 1
OUT 1
OPEN
CLOSE
COM
13 14 15
GND
12 3 4567
FLASHING LAMP
24VAC / MAX 20W
PHOTO TEST
9
GND
10 11 128
+ 24 VDC
5A FUSE
RC1
GND
+5
INTERNAL
RECEIVER
ANTENNA
NL
20
x
230 VAC
OPEN
CLOSE
COM
16 17 18
A
B
C
19
INPUT
T182A. SWING GATE CONTROL UNIT. POWER SUPPLY 230 VAC. FREQUENCY 433.92 MHz. 100 STORABLE CODES.
INPUTS:
1. START OR OPEN N.O.
2. STOP N.C.
3. EXTERNAL PHOTOCELL N.C.
closing phase: inverts the gate movement
4. INTERNAL PHOTOCELL N.C.
opening phase: pauses the gate movement
closing phase: inverts the gate movement
5. MOTOR «A» LIMIT SWITCHES N.O.
6. MOTOR «B» LIMIT SWITCHES N.O.
7. PEDESTRIAN ORCLOSE N.O
AUSILIARY OUTPUTS:
EXPANSION RELAY MODULE - OUT1. ENABLED/DISABLED VIA REMOTE (FUNCTION R4). IF THE RIGHT DIP10 IS ON, THE OUT1 IS ON FOR 3 MIN
AFTER EACH OPENING PHASE.
EXPANSION ELECTRIC-LOCK MODULE OUT2. ENABLED AT OPENING FOR 3 SEC.
21 345 6 78 9 10 11 12
21 345 6 78 9 10 11 12
OIL RECIRCULATION. DIP 6.
LEFT DIP-SWITCH (1) FUNCTIONS RIGHT DIP-SWITCH (2) FUNCTIONS
21 345 6 78 9 10
21 345 6 78 9 10
SLOW DOWN. DIP 3.
OFF = DISABLED
ON = ENABLED
POWER 100%
21 345 6 78 9 10
21 345 6 78 9 10
ELECTRONIC LIMIT SWITCH. DIP 5.
OFF = DISABLED
ON = ENABLED
MOTORS POWER. DIP 1 - 2.
21 345 6 78 9 10
21 345 6 78 9 10
21 345 6 78 9 10
21 345 6 78 9 10
OFF / OFF = 40%
ON / OFF = 60%
OFF / ON = 80%
ON / ON = 100%
21 345 6 78 9 10
21 345 6 78 9 10
21 345 6 78 9 10
21 345 6 78 9 10
SOFT START. DIP 6 - 7.
OFF / OFF = 0.1 sec
ON / OFF = 0.5 sec
OFF / ON = 1.0 sec
ON / ON = 1.5 sec
GATE LEAVES DELAY. DIP 8 - 9.
21 345 6 78 9 10
21 345 6 78 9 10
21 345 6 78 9 10
21 345 6 78 9 10
OFF / OFF = 0 sec
ON / OFF = 3 sec
OFF / ON = 6 sec
ON / ON = 12 sec
21 345 6 78 9 10
21 345 6 78 9 10
21 345 6 78 9 10
21 345 6 78 9 10
MODES. DIP 1 - 2.
OFF / OFF = AUTOMATIC CLOSURE
ON / OFF = COMMUNITY MODE
OFF / ON = STEP-BY-STEP MODE
ON / ON = STEP-BY-STEP + AUTOMATIC
CLOSURE
21 345 6 78 9 10
OFF =
2 MOTORS MODE
21 345 6 78 9 10
21 345 6 78 9 10
21 345 6 78 9 10
21 345 6 78 9 10
ELECTRIC-LOCK. DIP 3 - 4.
21 345 6 78 9 10
21 345 6 78 9 10
DISABLED NOT WIRED N.C. INPUTS. DIP 8.
OFF =
N.C. INPUTS ENABLED
ON =
NOT WIRED N.C.
INPUTS DISABLED
21 345 6 78 9 10
21 345 6 78 9 10
OBSTACLE DETECTION SENSOR. DIP 4.
OFF = DISABLED
ON = ENABLED 21 345 6 78 9 10
21 345 6 78 9 10
MOTORS AND PHOTOCELLS TESTS. DIP 10.
OFF = DISABLED
ON = ENABLED 21 345 6 78 9 10
21 345 6 78 9 10 OFF = DISABLED
ON = ENABLED
FAST CLOSURE. DIP 5.
21 345 6 78 9 10 11 12
21 345 6 78 9 10 11 12
INPUTS OPTION 1 - 7. DIP 9.
OFF =
ON =
INPUT 1 = START
INPUT 7 = PEDESTRIAN
INPUT 1 = OPEN
INPUT 7 = CLOSE
21 345 6 78 9 10
21 345 6 78 9 10
COURTESY LIGHT. DIP 10.
ON
LEFT / DIP-SWITCH RIGHT / DIP-SWITCH
STAND BY, GATE CLOSED
GATE IN OPENING OR CLOSING PHASE,
GATE OPEN
PROGRAMMING OF WORKING TIMES /
OBSTACLE SENSOR
BOARD STATUS:S1 S2 S3
PROGRAMMING ERROR
PHOTOCELLS ERROR
MOTOR A ERROR:
A
B
C
CONNECTION
ERROR OR MOTOR
OVERHEATING
CONNECTION
ERROR OR MOTOR
OVERHEATING
A
B
C
OBSTACLE
DETECTED
A
B
C
A
B
C
MOTOR B ERROR:
PROGRAM
TIME
OBSTACLE
A MOTOR B MOTOR
OUT 2
OUT 2
LEDs:
S1.S2.S3. GATE STATUS / CONTROL BOARD STATUS LEDS
RC1.RC2.R1.R2.R3.R4. RADIO LEDS
RC1. SHOWS THAT A SIGNAL HAS BEEN RECEIVED FROM THE INTERNAL RADIO RC1
RC2. SHOWS THAT A SIGNAL HAS BEEN RECEIVED FROM THE EXTERNAL RADIO RC2
R1. START: INDICATES THAT A START BUTTON ON THE REMOTE HAS BEEN PRESSED
R2. STOP: INDICATES THAT A STOP BUTTON ON THE REMOTE HAS BEEN PRESSED
R3. PEDESTRIAN: SHOWS THAT A START PEDESTRIAN BUTTON ON THE REMOTE HAS BEEN PRESSED
R4. OUT1 ON/OFF: SHOWS THAT A OUT1 BUTTON ON THE REMOTE HAS BEEN PRESSED
A.B.C. PROGRAMMING LEDS
1.2.3.4.5.6.7. INPUTS
OFF = DISABLED
ON = ENABLED
OFF = DISABLED
ON = ENABLED
OBSTACLE
DETECTED
OFF / OFF = STANDARD
ON / OFF = KICK BACK AT
CLOSING 1 sec
OFF / ON = KICK BACK AT
OPENING
ON / ON = KICK BACK AT
CLOSING + KICK BACK AT
OPENING
21 345 6 78 9 10 21 345 6 78 9 10
21 345 6 78 9 10
ON =
1 MOTOR MODE
MODE 1 OR 2 MOTORS. DIP 7.
G
R
O
U
N
D
OUT1 ON/OFF
R1. OFF
R2. OFF
R3. OFF
R4. ON
X4
RC1
RC2
ON
PEDESTRIAN
R1. OFF
R2. OFF
R3. ON
R4. OFF
X3
STOP
R1. OFF
R2. ON
R3. OFF
R4. OFF
X2
START
R1. ON
R2. OFF
R3. OFF
R4. OFF
X1
OUT1 ON/OFF
R1. OFF
R2. OFF
R3. OFF
R4. ON
X1
START
R1. ON
R2. OFF
R3. OFF
R4. OFF
X4
STOP
R1. OFF
R2. ON
R3. OFF
R4. OFF
X3
PEDESTRIAN
R1. OFF
R2. OFF
R3. ON
R4. OFF
X2
RC1
RC2
ON
R1. ON
R2. ON
R3. ON
R4. ON
R1. OFF
R2. OFF
R3. OFF
R4. OFF
R1. OFF
R2. ON
R3. ON
R4. ON
R1. OFF
R2. OFF
R3. ON
R4. ON
R1. OFF
R2. OFF
R3. OFF
R4. ON
START MOTORS
N
L
X
2019 5678910 11 122 3 4
1
56789
TEST GND
10 11 122 3 4
156789
N.C.
RX RX
GND+VDC
10 11 122 3 4
156789
GND+VDC
10 11 122 3 4
1
N.C.
TX
STOP
5678910 11 122 3 4
1
5678910 11 122 3 4
5678 9 10 11 122 3 4
1
5678910 11 122 3 4
1
+VDC
1
5678910 11 122 3 4
1
+VDC
OUT 1 OUT 2
MAX 20 W
Opening and closing
motor A limit switches. Opening and closing
motor B limit switches.
13.16 open 14.17 common 15.18 close
13 14 15
M
A16 17 18
M
B
MEMORIZE A REMOTE
DELETE A REMOTE
ERASE ALL REMOTES
PRESS AND HOLD THE DESIRED BUTTON ON THE REMOTE, SIMULTANEOUSLY PRESS ONCE THE REMOTE BUTTON ON THE CONTROL BOARD TO
MEMORIZE THE START FUNCTION, PRESS TWICE THE REMOTE BUTTON ON THE BOARD TO MEMORIZE THE STOP FUNCTION, PRESS THREE TIMES
THE REMOTE BUTTON ON THE BOARD TO MEMORIZE THE PEDESTRIAN FUNCTION, PRESS FOUR TIMES THE REMOTE BUTTON ON THE BOARD TO
MEMORIZE THE OUT1 ON/OFF FUNCTION. THE CORRESPONDING LED (R1-START, R2-STOP, R3-PEDESTRIAN, OR R4-OUT1) WILL BE STEADY ON TO
CONFIRM MEMORIZATION.
TO ERASE ALL SAVED REMOTES PRESS AND HOLD THE REMOTE BUTTON ON THE BOARD FOR 6 SECONDS. LEDS R1, R2, R3, AND R4 WILL GO ON
STEADY THEN WILL GO OFF INDICATING CORRECT DELETION OF ALL REMOTES.
PRESS AND HOLD THE REMOTE
BUTTON ON THE BOARD FOR
ABOUT 6 SECONDS.
PRESS AND HOLD THE DESIRED BUTTON ON THE REMOTE, SIMULTANEOUSLY PRESS FOUR TIMES THE REMOTE BUTTON ON THE CONTROL BOARD
TO DELETE THE START FUNCTION, PRESS THREE TIMES THE REMOTE BUTTON ON THE BOARD TO DELETE THE STOP FUNCTION, PRESS TWICE THE
REMOTE BUTTON ON THE BOARD TO DELETE THE PEDESTRIAN FUNCTION, OR PRESS ONCE THE REMOTE BUTTON ON THE BOARD TO DELETE THE
OUT1 ON/OFF FUNCTION.
POWER SUPPLY
EXTERNAL PHOTOCELL INTERNAL PHOTOCELL PEDESTRIANPHOTOCELLS TRANSMITTER
MOTOR «A» LIMIT SWITCH MOTOR «B» LIMIT SWITCH
TERMINAL BLOCK CONNECTIONS
FLASHING LAMP AUXILIARY OUTPUTS
OUT1. ENABLED/
DISABLED VIA
REMOTE
OUT2.
ELETTRICK-LOCK.
ENABLED DURING
OPENING FOR
3 SEC
PROGRAMMING OF OBSTACLE DETECTION SENSOR. The programming must be operated while the gate is closed.
PRESS AND HOLD THE OBSTACLE BUTTON ON THE BOARD FOR 5 SECONDS. The automac procedures starts:
Led A is steady on.
The control board is
seng the sensor in
presence of an obstacle.
Led A and B are steady on.
The gate starts opening ,
then it slows down. The
control board is seng the
sensor in absence of
obstacles.
Led A,B and C are steady on.
The gate starts closing,
then it slows down. The
control board goes back to
the inial posion of
the gate.
The procedure has ended.
The obstacle sensor is fully set.
A
B
C
S1 S2 S3
A
B
C
S1 S2 S3
A
B
C
S1 S2 S3
A
B
C
S1 S2 S3
PROGRAMMING OF GATE WORKING TIMES. The programming must be operated while the gate is closed.
A
B
C
S1 S2 S3
1 2
PRESS THE TIME BUTTON
3 4 56
A
B
C
S1 S2 S3 A
B
C
S1 S2 S3 A
B
C
S1 S2 S3 A
B
C
S1 S2 S3 A
B
C
S1 S2 S3
PRESS AND HOLD THE
TIME BUTTON FOR 5
SECONDS
Led A is steady on. The gate
leaf A is in the opening
phase. The control board is
acquiring the working me
of motor A.
PRESS THE TIME BUTTON PRESS THE TIME BUTTON PRESS THE TIME BUTTON PRESS THE TIME BUTTON
or a start commande
TO EXIT AND SAVE THE
PAUSE TIME
Led A is flashing. The gate
connues the opening
phase of leaf A in slow
down mode. The control
board is acquiring the
slow down me of leaf A.
Led A and B are steady on.
The gate leaf B is in the
opening phase. The control
board is acquiring the
working me of motor B.
Led A is steady on. Led B is
flashing. The gate connues
the opening phase of leaf B in
slow down mode. The
control board is acquiring
the slow down me of leaf B.
Led A and B are steady on.
Led C flashes every second.
The control board is
acquiring the pause me.
The gate will automacally
close aer the set pause
me.
or a start
commande or a start
commande or a start
commande or a start
commande
If the 1 motor mode is selected, follow the steps for motor A to program the working mes (1 - 2 - 5 - 6).
It's advisable to re-do the programming of the obstacle sensor every me the motor power is modified.
FUNCTIONS DESCRIPTION
MODES
TYPICAL INSTALLATION
INTERNAL PHOTOCELLS
CONNECT TO TERMINAL 4.
FLASHING LAMP
24 VAC / MAX 20 W
A MOTOR
OPENS FIRST.
B MOTOR
AUTOMATIC CLOSURE: THE GATE AUTOMATICALLY CLOSES AFTER THE SET PAUSE TIME.
• DURING CLOSING, A START OR PEDESTRIAN COMMAND INVERTS THE GATE MOVEMENT.
• DURING OPENING, A START OR PEDESTRIAN COMMAND STOPS THE GATE MOVEMENT.
COMMUNITY PLUS AUTOMATIC CLOSURE: THE GATE AUTOMATICALLY CLOSES AFTER THE SET PAUSE TIME.
• DURING CLOSING, A START OR PEDESTRIAN COMMAND INVERTS THE GATE MOVEMENT.
• DURING OPENING, A START OR PEDESTRIAN COMMAND IS IGNORED.
STEP-BY-STEP: THE GATE STAYS OPEN AT THE END OF THE OPENING PHASE.
• DURING CLOSING AND OPENING, A START OR PEDESTRIAN COMMAND STOPS THE GATE MOVEMENT.
STEP-BY-STEP PLUS AUTOMATIC CLOSURE: THE GATE AUTOMATICALLY CLOSES AFTER THE SET PAUSE TIME.
• DURING CLOSING AND OPENING, A START OR PEDESTRIAN COMMAND STOPS THE GATE MOVEMENT.
OBSTACLE SENSOR: IF THE CONTROL BOARD DETECTS AN OBSTACLE IT INVERTS THE GATE MOVEMENT OR ENDS THE WORKING PHASE. IT INVERTS
THE GATE MOVEMENT IF IT’S THE FIRST OBSTACLE DETECTION IN THE CURRENT WORKING CYCLE (OPENING/CLOSURE). OTHERWISE, IT ENDS THE
WORKING PHASE SO TO FIND THE FULLY OPEN/CLOSED GATE POSITION AND RESTORE THE STANDARD GATE FUNCTIONING.
ELECTRONIC LIMIT SWITCH/ OBSTACLE SENSOR SLOW DOWN: IF THE CONTROL BOARD DETECTS AN OBSTACLE DURING THE SLOW DOWN, IT ENDS
THE CURRENTWORKING PHASE AS AN ELECTRONIC LIMIT SWITCH WOULD DO.
INTERNAL PROPERTY
ANTENNA
WITH RADIO
CASE
EXTERNAL PHOTOCELLS
CONNECT TO TERMINAL 3.
ELECTRIC-LOCK
SLOW DOWN: THE GATE SLOWS DOWN FOR THE SET SLOW DOWN TIME AT THE END OF THE OPENING AND CLOSING PHASES. DURING THE SLOW
DOWN PHASE THE MOTORS WORKS AT THEIR MAX POWER.
PEDESTRIAN: ONLY GATE LEAF A IS INVOLVED IN THE OPENING PHASE. GATE LEAF B REMAINS CLOSED.
SOFT START: THE MOTORS POWER INCREASES GRADUALLY TILL IT REACHES ITS MAX VALUE.
TESTS: THE CORRECT FUNCTIONING OF MOTOR AND PHOTOCELLS ARE CHECKED BEFORE ANY GATE MOVEMENT. IF ONE OF THE TWO TESTS FAILS
THE GATE DOES NOT MOVE. THE LEDS ON THE BOARD INDICATES THE TYPE OF FAILURE. THE MOTORS TEST FAILS WHEN ONE OR BOTH MOTORS
ARE IN TERMAL PROTECTION OR THERE IS A CONNECTION ERROR. THE PHOTOCELLS TEST FAILS IF TRANSMITTER AND RECEIVER ARE NOT PROPERLY
ALIGNED, IF THERE ARE INSTALLATION ERRORS, OR IF THE PHOTOCELLS ARE DAMAGED.
DISABLE NOT WIRED N.C. INPUTS: DISABLE ALL THE NOT WIRED N.C. INPUTS. IF LATER, A N.C. INPUT IS WIRED, THE BOARD WILL AUTOMATICALLY
ENABLE IT.
SINGLE MOTOR MODE: USEFUL FOR SINGLE LEAF SWING GATES. ONLY MOTOR A WILL BE ACTIVATED. THE WORKING TIMES AND OBSTACLE
SENSOR WILL BE ENABLED ONLYFOR MOTOR A.
FAST CLOSURE: THE GATE STARTS THE CLOSING PHASE 3 SEC AFTER THE INTERNAL/EXTERNAL OR EXTERNAL/INTERNAL PHOTOCELLS HAVE BEEN
ACTIVATED. THIS FUNCTION WORKS ONLY ONCE PER WORKING CYCLE AND ONLY IF THE GATE HAS NOT BEEN STOPPED DURING OPENING OR
CLOSING.
OIL RECIRCULATION / COLD CLIMATE MODE: THE MOTOR IS ACTIVATED AT THE MINIMUM POWER FOR 1 MIN EVERY 10 MIN WHEN THE GATE IS
FULLY OPEN/CLOSED, IF MORE THAN 20 MIN LASTED FROM LAST GATE MOVEMENT.
ELECTRIC-LOCK.
1. CONNECT TO OUT2.
10 12
+ - E.LOCK
10 12
OUT2 OUT2
10 12
10
12
ELECTRIC-LOCK
+
-
ELECTRIC-LOCK: ENABLED DURING OPENING FOR 3 SEC.
• KICK BACK AT CLOSING: AT THE END OF EACH CLOSING PHASE MOTOR A PUSHES THE LEAF A FOR 1 SEC AT MAX POWER SO TO PROPERLY CLOSE
THE GATE.
• KICK BACK AT OPENING: THE FIRST TIME THE GATE OPENS, THE GATE CLOSES FOR 1 SEC WITH THE ELECTRIC-LOCK ENABLED. AFTER THAT, THE
ELECTRIC-LOCK IS ENABLED FOR 3 SEC DURING OPENING.
• KICK BACK AT CLOSING AND OPENING: ENABLED THE FUNCTIONS PREVIOUSLY DESCRIBED.
2. CONNECT BOARD TERMINAL BLOCK
PINS 10 AND 12 TO ELECTRIC-LOCK
TERMINAL BLOCK PINS 10 AND 12.
3. CONNECT ELECTRIC-LOCK MODULE
PINS + AND - TO ELECTRIC-LOCK PINS
+ AND -
SUGGESTIONS
THE RADIO CASE CAN BE
INSTALLED IN COMBINATION
WITH THE FLASHING LAMP ONE UP.
THE RADIO
MODULE
HOUSED INSIDE
THE RADIO CASE
(RANPC5T).
TO INCREASE THE SIGNAL RANGE DISCONNECT THE RADIO MODULE FROM THE INTERNAL RECEIVER
POSITION AND WIRE IT ON THE TERMINAL BLOCK EXTERNAL RECEIVER POSITION. IF AVAILABLE, WE
SUGGEST YOU USE THE RADIO CASE (CODE RANPC5T).
1. RADIO MODULE CONNECTED IN
INTERNALRECEIVER POSITION
(DEFAULT CONFIGURATION).
2. DISCONNECT THE RADIO
MODULE FROMTHE INTERNAL
RECEIVER POSITION.
3. WIRE THE RADIO MODULE ON THE
TERMINAL BLOCK EXTERNAL RECEIVER
POSITION.
3. WIRE THE RADIO MODULE
ON THE TERMINAL
BLOCK EXTERNAL
RECEIVER
POSITION.
x x x
USER MANUAL
T182A
ENG
MADE IN ITALY
T.A. Tecno Automazione s.r.l. - Via Vicinale snc - 03018 - Paliano - (FR) - Italy - Tel +39 0775 533677 - Fax +39 0775 533299 - [email protected] - www.tecnoautomation.com - www.tecnoautomazione.com
For private households: Informaon on Disposal for Users of WEEE This symbol on the product(s) and / or accompanying documents means that used electrical and electronicequipment (WEEE)
should not be mixed with general household waste. For proper treatment, recovery and recycling, please take this product(s) to designated collecon points where it will be accepted free of
charge. Alternavely, in some countries, you may be able to return your products to your local retailer upon purchase of an equivalent new product. Disposing of this product correctly will help
save valuable resources and prevent any potenal negave effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please contact your
local authority for further details of your nearest designated collecon point. Penales may be applicable for incorrect disposal of this waste, in accordance with you naonal legislaon. For
professional users in the European Union If you wish to discard electrical and electronic equipment (EEE), please contact your dealer or supplier for further informaon. For disposal in countries
outside of the European Union This symbol is only valid in the European Union (EU). If you wish to discard this product please contact your local authories ordealer and ask for the correct
method of disposal.

Other Tecnoautomazione Control Unit manuals

Tecnoautomazione T181P User manual

Tecnoautomazione

Tecnoautomazione T181P User manual

Tecnoautomazione T182S User manual

Tecnoautomazione

Tecnoautomazione T182S User manual

Tecnoautomazione T181S User manual

Tecnoautomazione

Tecnoautomazione T181S User manual

Popular Control Unit manuals by other brands

Honeywell HS10S installation instructions

Honeywell

Honeywell HS10S installation instructions

BroadMobi BM818 Operation manual

BroadMobi

BroadMobi BM818 Operation manual

VAT 48 Series Installation, operating,  & maintenance instructions

VAT

VAT 48 Series Installation, operating, & maintenance instructions

ICM Controls ICM275 installation instructions

ICM Controls

ICM Controls ICM275 installation instructions

Texas Instruments TDC7200EVM user guide

Texas Instruments

Texas Instruments TDC7200EVM user guide

Hasco H1281-6 operating instructions

Hasco

Hasco H1281-6 operating instructions

MSA M1 operating manual

MSA

MSA M1 operating manual

Honeywell AlarmNet 7845GSM Quick setup guide

Honeywell

Honeywell AlarmNet 7845GSM Quick setup guide

Burkert AirLINE 8652 Series operating instructions

Burkert

Burkert AirLINE 8652 Series operating instructions

Nibe SMO S40 user manual

Nibe

Nibe SMO S40 user manual

AMX 8450-03 installation guide

AMX

AMX 8450-03 installation guide

rtd cpuModule CMC6686GX user manual

rtd

rtd cpuModule CMC6686GX user manual

HID ACW2-XN Quick install guide

HID

HID ACW2-XN Quick install guide

Cornelius MFV How-to

Cornelius

Cornelius MFV How-to

Festo CPX-FVDA-P2 Original instructions

Festo

Festo CPX-FVDA-P2 Original instructions

Rittal 7320.790 Assembly and operating instructions

Rittal

Rittal 7320.790 Assembly and operating instructions

FabiaTech FB2410 Series User's quick setting

FabiaTech

FabiaTech FB2410 Series User's quick setting

NI 9265E Operating instructions and specifications

NI

NI 9265E Operating instructions and specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.