Jumper Settings
www.ti.com
18 SBOU060A–July 2008–Revised September 2016
Submit Documentation Feedback
Copyright © 2008–2016, Texas Instruments Incorporated
Hardware Connections and Jumper Settings
Table 3-2 summarizes the function of the USB DAQ platform jumpers. For most applications, the default
jumper position should be used. A separate document (SBOU056) gives details regarding the operation
and design of the USB DAQ platform.
Table 3-2. USB DAQ Platform Jumper Settings (5-V Power Supply)
Jumper Default Purpose
JUMP17 BUS BUS or VRAW.BUS is the safe mode. The VRAW option is only used for special
test modes. In the VRAW position it is possible to damage the USB DAQ platform
with voltages above 5.5 V.
JUMP13 REG REG or BUS. In the REG position the regulator provides VDUT power.
JUMP14 9 V 9 V or BUS. In the 9-V position an external power supply provides power to the
EVM. In the BUS position the USB bus powers the EVM.
JUMP9 5 V 5Vor 3 V. In the 5-V position a variable regulator is resister programmed to 5 V.
In the 3-V position a variable regulator is resistor programmed to 3 V.
JUMP6 5 V 5 V or 3 V. In the 5-V position, a stacked 5-V reference is connected to the
ADCs and DACs on the USB DAQ platform. In the 3-V position, a 3-V reference
is connected to the ADCs and DACs on the USB DAQ platform.
JUMP7 Ref Ref or Reg. In the Ref position, a calibrated reference is connected to the USB
DAQ platform ADC and DAC. In the Reg position, the regulator output (such as
a power-supply voltage) is connected to the USB DAQ platform ADC and DAC.
JUMP1 EXT EXT or BUS. In the external position the USB DAQ platform receives power from
an external dc power source (such as through J5 or T3). The BUS position
allows for the USB bus to power the EVM. External mode is recommended.
JUMP11 WP_ON WP_ON or WP_OFF. In the WP_ON position, the calibration EEPROM is write
protected. In the WP_OFF position, the calibration EEPROM is not write
protected.
JUMP8 SPD_UP SPD_UP or GND. In the SPD_UP position, the one-wire signal has a boost on
the rising edge to allow for transmission over long cables. In the GND position,
the speed-up feature is turned off.
JUMP10 WP_ON WP_ON or WP_OFF. In the WP_ON position, the firmware EEPROM is write
protected. In the WP_OFF position, the firmware EEPROM is not write
protected.
JUMP3 EE ON EE ON or EE OFF. In the EE ON position, the firmware EEPROM is connected
to the microcontroller for normal operation. In the EE OFF position, the firmware
EEPROM is disconnected to the microcontroller; this mode is used to program
the EEPROM.
JUMP2 EXT EXT or BUS. In the external position the USB DAQ platform receives power from
an external dc power source (such as through J5 or T3). The BUS position
allows for the USB bus to power the EVM. External mode is recommended.
JUMP18 VDUT
VCC or VDUT. In the VDUT position, the digital output pull-up resistors are
connected to VCC. In the VCC position, the digital output pull-up resistors are
connected to VCC.
JUMP4 L Lor H. This jumper sets the USB DAQ platform USB address.
JUMP5 L Lor H. This jumper sets the USB DAQ platform USB address.