SPECIFICATIONS
–56.2 to 572.0°F (–49.9 to 299.9°C)
0.1° or 1° - user selectable
±0.72°F (–58 to 392°F), ±1.8°F (392 to 572°F)
±0.4°C (–49.9 to 199.9°C), ±1°C (200 to 299.9°C)
Type K thermocouple
–4 to 122°F (–20 to 50°C)
2 x 3 volt CR2032 lithium coin cell
1500 hours
0.55" (14mm) LCD
0.75 H x 1.85 W x 6.1 D inches
(19 H x 47 W x 153 D mm)
0.25lb. (97g)
Range
Resolution
Accuracy
Sensor Type
Operating Range
Battery
Battery Life
Display
Dimensions
Weight
PRODUCT WARRANTY - This instrument carries a two-
year warranty against defects in either components or
workmanship. During this period, products that prove to be
defective will, at the discretion of ThermoWorks, be either
repaired or replaced without charge. This warranty does not
apply to probes, where a six-month period is offered. Full
details of liability are available within ThermoWorks’ Terms
& Conditions of Sale at www.thermoworks.com/product-
warranty.
ACCESSORIES
For warranty, service, and technical assistance,
please contact ThermoWorks’ Technical Support at (801)
756-7705 or email at techsupport@thermoworks.com.
Made in the UK
SILICONE
BOOT
Model: 830-260
WALL MOUNT
BRACKET
Model: 10203
MAGNETIC
GLOW-IN-THE-DARK
SILICONE BOOT
Model: 830-265
INSTRUMENT OPERATION
The instrument is switched on
by unfolding the probe until the
display shows the temperature.
The unit is turned off by folding
the probe back into the side of
the unit. The probe should not be
rotated more than 180 degrees
as damage will occur. It is recommended to store the
probe, in the closed position, when not in use.
Apply the tip of the probe to the substance, surface or area
to be measured. The probe should be allowed adequate
time to stabilize to the temperature of the item to be
measured.
INSTRUMENT CONFIGURATION This instrument has four
user selectable slide switches (switch bank), adjustable
with a paperclip, and a single push button ‘Trim Adjust’
which is located under the battery cover.
Switch 1 – Units
Changes the instrument’s display units between (°F)
Fahrenheit and (°C) Celsius. The factory default is °F or
switch set farthest from batteries. To change to °C, move
the switch to the position closest to the batteries.
Switch 2 – Resolution
Changes the instrument’s display resolution between 1°(F
or C) and 0.1°(F or C). The factory default is 1° resolution
or switch set farthest from the batteries. To change to 0.1°
resolution, move the switch to the position closest to the
batteries.
Switch 3 – Auto-Off
Enables or disables the auto-off function. If the auto-
off function is enabled (factory default), the unit will
automatically turn off after 10 minutes to preserve battery
life. If disabled, the unit will remain on until the probe is
folded away and turned off by the user. The factory default
is auto-off enabled or switch set closest to the batteries. To
disable the auto-off function move the switch to the position
farthest from the batteries.
Switch 4 – Trim Adjust
If the Thermapen is within specification, we do not
recommend using the Trim Adjust. It should not be
needed in normal use. This mode allows the user to set
an offset that will add or subtract up to 3.6°F (2.0°C) to
all readings of the Thermapen. It can therefore be used to
tune the calibration. For detailed instructions visit www.
thermoworks.com.
INSTRUMENT CLEANING - Clean the instrument regularly
with an anti-microbial probe wipe or spray cleaner on a
paper towel to avoid potential food-borne bacteria growth.
WARNING - IPA and other solvents may cause damage to
the case and screen of this instrument.
BATTERY REPLACEMENT - A
battery symbol indicates that the
batteries will need replacing. The
instrument continues to measure
accurately but we recommend
that the batteries be changed
as soon as possible. To replace
the batteries, remove the battery
cover using a coin (U.S. quarter works best). Using firm
but even downward pressure, rotate the battery cover to the
open position. Remove the batteries by pulling the battery
retaining clip back while holding the unit upside down.
Replace both batteries, positive side up, replace cover.
ERROR MESSAGES - ‘Lo’ will be displayed if you are
measuring below the instrument’s range. ‘Hi’ will be
displayed if you are measuring above the instrument’s
range. ‘Err’ will be displayed if the probe develops a fault.
If the error message remains, contact ThermoWorks
Technical Support at (801) 756-7705 or email
techsupport@thermoworks.com.
EMC/RFI - Instrument performance may be affected if
operated within a high frequency radio field, such as near a
mobile phone, or if subjected to an electrostatic shock.
Recommendations for improving surface temperature
measurements (Pro-Surface Thermapen):
1. Surface readings may be affected by airflow, sensor
contact with the surface being measured, the surface
type, surface inconsistencies, and measuring area
cleanliness.
2. Make sure that the flat bottom area of the probe tip
maintains constant and flat contact with the surface
being measured.
3. Apply firm pressure. Allow sufficient time for the
reading to stabilize.
4. Clean surface before taking measurements.
5. Readings may be enhanced with a small amount of
cooking oil to establish better thermal contact with the
sensing area.
6. Surface temperatures may vary along hot surfaces. It
is recommended to test in multiple locations.
CR2032
3V
+
1234
ON
1234
ON
Switch bank
CR2032 battery
Trim adjust
Switch
(factory default shown)
CR2032
3V
+
1234
ON

This manual suits for next models

1

Other ThermoWorks Thermometer manuals

ThermoWorks WAND User manual

ThermoWorks

ThermoWorks WAND User manual

ThermoWorks RayTemp 2 Plus User manual

ThermoWorks

ThermoWorks RayTemp 2 Plus User manual

ThermoWorks IR-IND User manual

ThermoWorks

ThermoWorks IR-IND User manual

ThermoWorks Therma 20 Plus User manual

ThermoWorks

ThermoWorks Therma 20 Plus User manual

ThermoWorks BlueDOT User manual

ThermoWorks

ThermoWorks BlueDOT User manual

ThermoWorks Thermapen Blue User manual

ThermoWorks

ThermoWorks Thermapen Blue User manual

ThermoWorks Thermapen IR User manual

ThermoWorks

ThermoWorks Thermapen IR User manual

ThermoWorks ThermoPop User manual

ThermoWorks

ThermoWorks ThermoPop User manual

ThermoWorks Super-Fast Thermapen User manual

ThermoWorks

ThermoWorks Super-Fast Thermapen User manual

ThermoWorks ChefAlarm TX-1100-OR User manual

ThermoWorks

ThermoWorks ChefAlarm TX-1100-OR User manual

ThermoWorks CF-IR User manual

ThermoWorks

ThermoWorks CF-IR User manual

ThermoWorks Pro-Surface Thermapen User manual

ThermoWorks

ThermoWorks Pro-Surface Thermapen User manual

ThermoWorks Super-Fast Thermapen User manual

ThermoWorks

ThermoWorks Super-Fast Thermapen User manual

ThermoWorks Saf-T-Log User manual

ThermoWorks

ThermoWorks Saf-T-Log User manual

ThermoWorks Precision User manual

ThermoWorks

ThermoWorks Precision User manual

ThermoWorks MTC User manual

ThermoWorks

ThermoWorks MTC User manual

ThermoWorks TW362B User manual

ThermoWorks

ThermoWorks TW362B User manual

ThermoWorks Thermapen Blue User manual

ThermoWorks

ThermoWorks Thermapen Blue User manual

ThermoWorks TW362B User manual

ThermoWorks

ThermoWorks TW362B User manual

ThermoWorks IP-PRO-100 User manual

ThermoWorks

ThermoWorks IP-PRO-100 User manual

ThermoWorks TW362B ThermoWorks User manual

ThermoWorks

ThermoWorks TW362B ThermoWorks User manual

ThermoWorks Thermapen Series User manual

ThermoWorks

ThermoWorks Thermapen Series User manual

ThermoWorks Smoke User manual

ThermoWorks

ThermoWorks Smoke User manual

ThermoWorks TempTest Blue User manual

ThermoWorks

ThermoWorks TempTest Blue User manual

Popular Thermometer manuals by other brands

optris CTvideo 1M Operator's manual

optris

optris CTvideo 1M Operator's manual

Helmer DT1 manual

Helmer

Helmer DT1 manual

Oregon Scientific RAR681 user manual

Oregon Scientific

Oregon Scientific RAR681 user manual

HoMedics JUMBO DISPLAY manual

HoMedics

HoMedics JUMBO DISPLAY manual

Powerfix Profi 291541 Operation and safety notes

Powerfix Profi

Powerfix Profi 291541 Operation and safety notes

Hama TC-500 operating instructions

Hama

Hama TC-500 operating instructions

PACOM PC808 user manual

PACOM

PACOM PC808 user manual

Fluke 562 user manual

Fluke

Fluke 562 user manual

DeWalt DCT414 Original instructions

DeWalt

DeWalt DCT414 Original instructions

IKEA FANTAST user manual

IKEA

IKEA FANTAST user manual

FLIR TG54 user manual

FLIR

FLIR TG54 user manual

VIO 11000 operating instructions

VIO

VIO 11000 operating instructions

LifeSource DT-604 user manual

LifeSource

LifeSource DT-604 user manual

Triplett IRT227 user manual

Triplett

Triplett IRT227 user manual

VisioFocus 06400 user manual

VisioFocus

VisioFocus 06400 user manual

HYGIPLAS F314 instruction manual

HYGIPLAS

HYGIPLAS F314 instruction manual

YOKOGAWA TX1001 user manual

YOKOGAWA

YOKOGAWA TX1001 user manual

Perel CWT20 manual

Perel

Perel CWT20 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.