CF-IR Close Focus Infrared Thermometer
Thank you for purchasing our non-contact infrared thermometer.
OVERVIEW
1. LCD
2. MODE button
3. SCAN button
4. Battery cover
5. Infrared sensor
6. Lasers
7. Protective cover
SPECIFICATIONS
Thermometer Measurement Range -67 to 428°F / -55 to 220°C
Ambient Operating Temperature 32 to 122°F / 0 to 50°C
Display Resolution Thermometer: 0.2°C / 0.5°F; Stop Watch: 1 sec.
Accuracy (Tamb=23 ±3°C)* -55 to 0°C; ±(2+0.05/deg)°C; above 0°C; ±2°C (4°F)
or ±2% of the reading, whichever is greater.
Measurement Distance 0.7 inch / 18mm, with a 0.1 inch / 2.5mm spot size
Emissivity 0.95 default; adjustable to 1 in 0.05 increments
Features Auto real time clock and room temperature while
power is off; °C/°F switchable;
MIN/MAX/LOCK, stop watch
Battery Type AAA x 2
Battery Life 15 hrs continuous (auto power off after 15 sec)
Dimensions 6.7 (W) x 1.5 (H) x 1.0 (D) inches /
170 (W) x 38 (H) x 25 (D) mm
Weight 4.4 oz/ 125 grams including two AAA cells
Certificate Includes Certificate of Conformance
*IR accuracy can be affected by the
emissivity setting, target spot size,
rapid changes in ambient temperature,
and environmental conditions.
SETTING THE CLOCK
1. Press the SCAN button to turn the thermometer on. Press the MODE button seven times until the SET icon flashes.
2. Press the SCAN button to choose between the 12 or 24 hour time format.
3. Press the MODE button to select the hours. The hour digits will blink. Press the SCAN button to set the hours.
4. Press the MODE button to select the minutes. The minutes digits will blink. Press the SCAN button to set the minutes.
5. Press the MODE button when done.
Close Focus IR
MODE
801-756-7705
www.thermoworks.com
Meas. area
ø
0.1" (2.5mm)
ø
0.47" (12mm)
0.67"
(17mm)
0.63"
(16mm)
Close Focus IR
MODE
801-756-7705
www.thermoworks.com
Meas. area
ø
0.1" (2.5mm)
ø
0.47" (12mm)
0.67"
(17mm)
0.63"
(16mm)
1
2
36
4
7
5
OPERATING INSTRUCTIONS
1. Information is displayed on the LCD through the following symbols:
A. 12/24 hr indicator
B. Clock
C. SET icon
D. COUNT icon
E. LOCK indicator
F. Selected temperature scale
(˚C or ˚F)
G. Ambient temperature icon
H. Temperature reading
I. MIN/MAX indicators
J. HOLD Indicator
K. SCAN indicator
L. Low battery indicator
2. Remove the protective cover from the sensor end of the thermometer.
3. Press the SCAN button to turn the thermometer on.
4. Hold the thermometer like a pen. Position the infrared sensor 0.7 inches / 18mm from the object to be measured.
5. Press and hold the SCAN button with the index finger. The two lasers will converge into one when the exact distance is
obtained. Be sure the target is located at this focal point. The area measured is 0.1 inches / 2.5mm in diameter.
6. Pressing the SCAN button momentarily will result in a momentary reading. Holding the SCAN button will result in a
continuous reading.
7. The thermometer will automatically power off if left idle for more than 15 seconds. If you have set the CLOCK mode,
the clock and ambient room temperature will continue to display even after 15 seconds.
USING THE STOP WATCH
1. Press the SCAN button to turn the thermometer on.
Press the MODE button six times until the COUNT icon flashes.
2. Press the SCAN button to start or stop the stop watch.
Press the MODE button to reset the stop watch to zero.
OTHER FUNCTIONS
Power on and press the MODE button once for the Minimum (MIN) or twice for
Maximum (MAX) modes. When the MIN or MAX icon flashes, press the SCAN button
to confirm. Hold down the SCAN button, the minimum or maximum reading of
measurement will be continuously updated.
Power on and press the MODE button three times. When the LOCK icon flashes,
press the SCAN button to confirm. This mode is particularly useful for continuous
monitoring of temperatures for up to 60 minutes or until the SCAN button is pressed.
Power on and press the MODE button four times. When the °C icon flashes, press
the SCAN button to change the scale to °F.
Power on and press the MODE button five times. When the default emissivity “95E”
appears, press the SCAN button to modify the emissivity setting. Press MODE button
when complete.
Close Focus IR
MODE
801-756-7705
www.thermoworks.com
Meas. area
ø
0.1" (2.5mm)
ø
0.47" (12mm)
0.67"
(17mm)
0.63"
(16mm)
Close Focus IR
MODE
801-756-7705
www.thermoworks.com
Meas. area
ø
0.1" (2.5mm)
ø
0.47" (12mm)
0.67"
(17mm)
0.63"
(16mm)
LK
ABC
D
J
I
E
GF
H
<30 min
Min:Sec = 01:28 & 0.75 sec
>30 min
Hour:Min:Sec = 01:28:47 sec
(resolution = 0.01 sec, range to 24 hour
MIN/MAX
LOCK
°C /°F
Emissivity
CAUTION
1. Do not look directly into the laser beam. Permanent eye damage may result.
2. Never point the device towards anyone’s eyes.
3. Keep out of reach of all children.
STORAGE & CLEANING
The sensor lens should be kept clean at all times and stored at room temperature. Use only a soft cloth or cotton swab
with mater or medical alcohol when cleaning the lens. Allow the lens to fully dry before using. Clean the thermometer
with a damp cloth. The thermometer should be stored between -4 to 149°F / -20 to 65°C.
Readings may be affected if the thermometer is operated within a radio frequency electromagnetic field strength of
approximately 3 volts per meter, but its performance will not be permanently affected. Under an electromagnetic field of
3V/m from 300 to 350 mHz the maximum error is ±6°C.
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
Er2 is displayed when the thermometer is exposed to rapid changes in the ambient temperature.
Er3 is displayed when the ambient temperature exceeds 0°C (32°F) or +50°C (122°F). The thermometer
should be allowed plenty of time (minimum 30 minutes) to stabilize to the working/room temperature.
Er is displayed for all other error messages. Clear the error by resetting the thermometer. To reset, turn the
thermometer off, remove the batteries and wait for a minimum of one minute. Reinsert the batteries and turn
it on. If the error message remains please contact ThermoWorks for further assistance.
Hi or Lo is displayed when the temperature being measured exceeds the measurement range of the
thermometer.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’ ‘Battery Low’: battery
needs to be replaced.
‘Battery Exhausted’:
measurements may be
affected.
Alpine, Utah
Ph: 801-756-7705
Fax: 801-756-8948
www.thermoworks.com
CERTIFICATE OF CONFORMANCE
Themanufacturerofthisinstrument has implemented a quality assurance
system under ISO 9001:2000 certified quality system and fully follow
ISO GUM (Guide to the Expression of Uncertainty in Measurement)
to evaluate the uncertainty of temperature and resistance standards,
guarantee performance as below:
Calibration
Temperature
Max
Error
Target
Accuracy
Target
Stability
-30°C ±2.0°C ±0.3°C 0.3°C
0°C ±2.0°C ±0.4°C 0.1°C
100°C ±2.0°C ±0.4°C 0.1°C
200°C ±4.0°C ±0.5°C 0.1°C
Note: Assume the operation ambient temperature under 23 ±3°C
Furthermore, we certify that this infrared thermometer has been
inspected and found to comply with published specifications. This
device has been calibrated by temperature and/or resistance standards
that are traceable to NIST (U.S. National Institute of Standards and
Technology) or NML (National Measurement Laboratory) of Taiwan,
and the calibration procedure corresponds with generally accepted
regulations and standards.
ThermoWorks, Inc.
270 N. Main St., Suite D
Alpine, UT 84004
www.thermoworks.com

Other ThermoWorks Thermometer manuals

ThermoWorks WAND Blue User manual

ThermoWorks

ThermoWorks WAND Blue User manual

ThermoWorks ThermoPop User manual

ThermoWorks

ThermoWorks ThermoPop User manual

ThermoWorks Pro-Surface Thermapen User manual

ThermoWorks

ThermoWorks Pro-Surface Thermapen User manual

ThermoWorks ThermaGuard Series User manual

ThermoWorks

ThermoWorks ThermaGuard Series User manual

ThermoWorks Signals User manual

ThermoWorks

ThermoWorks Signals User manual

ThermoWorks TW8060 User manual

ThermoWorks

ThermoWorks TW8060 User manual

ThermoWorks Smoke X4 Instruction and safety manual

ThermoWorks

ThermoWorks Smoke X4 Instruction and safety manual

ThermoWorks ThermoPop User manual

ThermoWorks

ThermoWorks ThermoPop User manual

ThermoWorks TempTest Blue User manual

ThermoWorks

ThermoWorks TempTest Blue User manual

ThermoWorks Therma Differential User manual

ThermoWorks

ThermoWorks Therma Differential User manual

ThermoWorks Signals User manual

ThermoWorks

ThermoWorks Signals User manual

ThermoWorks Saf-T-Log User manual

ThermoWorks

ThermoWorks Saf-T-Log User manual

ThermoWorks RayTemp Blue User manual

ThermoWorks

ThermoWorks RayTemp Blue User manual

ThermoWorks MicroTherma 2K User manual

ThermoWorks

ThermoWorks MicroTherma 2K User manual

ThermoWorks Therma 20 Plus User manual

ThermoWorks

ThermoWorks Therma 20 Plus User manual

ThermoWorks TempTest 2 User manual

ThermoWorks

ThermoWorks TempTest 2 User manual

ThermoWorks BlueDOT User manual

ThermoWorks

ThermoWorks BlueDOT User manual

ThermoWorks Therma K User manual

ThermoWorks

ThermoWorks Therma K User manual

ThermoWorks TW362B User manual

ThermoWorks

ThermoWorks TW362B User manual

ThermoWorks ChefAlarm TX-1100-OR User manual

ThermoWorks

ThermoWorks ChefAlarm TX-1100-OR User manual

ThermoWorks IR-IND User manual

ThermoWorks

ThermoWorks IR-IND User manual

ThermoWorks RayTemp 2 Plus User manual

ThermoWorks

ThermoWorks RayTemp 2 Plus User manual

ThermoWorks TW362B User manual

ThermoWorks

ThermoWorks TW362B User manual

ThermoWorks Saf-T-Log User manual

ThermoWorks

ThermoWorks Saf-T-Log User manual

Popular Thermometer manuals by other brands

NTN-SNR LASER TEMP 301 user manual

NTN-SNR

NTN-SNR LASER TEMP 301 user manual

Hama TH-200 Operating	 instruction

Hama

Hama TH-200 Operating instruction

ThermoProbe TL3-A user manual

ThermoProbe

ThermoProbe TL3-A user manual

Ambient Weather WS-0270 user manual

Ambient Weather

Ambient Weather WS-0270 user manual

GREISINGER GMH 2710-T operating manual

GREISINGER

GREISINGER GMH 2710-T operating manual

bewell connect MyThermo BW-CX10 user manual

bewell connect

bewell connect MyThermo BW-CX10 user manual

Radio Shack MTR661 user manual

Radio Shack

Radio Shack MTR661 user manual

UEi INF195C instruction manual

UEi

UEi INF195C instruction manual

ACU-RITE 990 instruction manual

ACU-RITE

ACU-RITE 990 instruction manual

Omega HH11B instruction sheet

Omega

Omega HH11B instruction sheet

lifelong DT-8861 manual

lifelong

lifelong DT-8861 manual

TESTO 915i quick start guide

TESTO

TESTO 915i quick start guide

HM Digital ORP-200 user guide

HM Digital

HM Digital ORP-200 user guide

TESTO 935 instruction manual

TESTO

TESTO 935 instruction manual

SIKA DiTemp LCK operating manual

SIKA

SIKA DiTemp LCK operating manual

IBP MT 301 instruction manual

IBP

IBP MT 301 instruction manual

Ebro TLC 730 manual

Ebro

Ebro TLC 730 manual

ELECHICO CCIR1001 instructions

ELECHICO

ELECHICO CCIR1001 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.