INSTRUMENT OPERATION - The instrument is switched
on by pressing the Transmit button. The instrument
takes approximately 2 seconds to start up. After this the
temperature is displayed and the instrument continues to
measure at its set measurement rate (default 1 second).
The instrument is now ready for a Bluetooth®connection
to a phone or tablet, but can be used without a wireless
connection.
Apply the tip of the probe to the substance, medium or
surface to be measured. The sensor is located at the tip of
the probe, therefore the minimum depth insertion should be
0.12″(3 mm).
The probe tip is very sharp and can remain hot therefore
caution should be taken when using.
CONNECTION - Use a Bluetooth®enabled iOS or Android™
host device with HACCP LE installed to connect to the
instrument. HACCP LE can be downloaded free from the
Apple App Store or on Google Play™. Open HACCP LE
and connect to the device via the Devices screen, use the
instrument’s serial number to select the correct device from
the list. When connecting/disconnecting, the instrument's
amber light flashes rapidly 5 times. Once connected,
HACCP LE will begin receiving and displaying measurement
data.
TRANSMIT BUTTON FUNCTIONS:
•On – Press to switch the instrument on.
•Measure/Transmit – Press to measure
temperature and transmit result via Bluetooth
wireless technology (if connected).
•Off – hold down for 3 seconds to switch the
instrument off.
LCD INDICATIONS
The LCD automatically rotates to indicate temperatures at
the angle the instrument is being held.
- Indicates a low battery level – see Battery
Replacement section.
• ‘Hi’ – temperature reading is above 572°F
• ‘Lo’ – temperature reading is below –58°F
• ‘AHi’ – instruments ambient is above 122°F
• ‘ALo’ – instruments ambient is below –4°F
• ‘Err’ – sensor fault or open circuit
LED INDICATIONS
The instrument has an amber light located just above the
LCD to indicate Bluetooth connection status:
• 5 rapid flashes indicate when connecting or
disconnecting.
• A single flash every 10 seconds indicates you are still
connected.
• When connected and the Transmit button is pressed,
a single flash indicates that the temperature has been
transmitted via Bluetooth wireless technology.
SETTINGS - Adjustable through HACCP LE include: °C
or °F, Measurement Interval, Auto-off Interval, Sensor
Name, and High/Low Alarm levels. All settings are stored
in the instrument and are downloaded to HACCP LE on
connection.
AUTO-OFF - If the instrument is not connected to a phone/
tablet or the Transmit button is not pressed within the set
Auto-off interval (default 10 minutes) then it will switch off.
BATTERY REPLACEMENT - The low battery symbol will
indicate when the batteries need replacing. The instrument
continues to measure accurately but it’s recommended that
the batteries are changed as soon as possible. To replace
the batteries, remove the battery cover on the bottom using
phillips screwdriver. Replace the 2 x AAA batteries ensuring
correct polarities. Replace the cover and tighten to ensure
the unit remains waterproof. Do not overtighten. Please
note: the battery cover can only be fitted one way.
INSTRUMENT CLEANING - Clean the instrument regularly
with an anti-bacterial probe wipe to avoid potential food-
borne bacteria growth.
WARNING - IPA and other solvents may cause damage to
the case of this instrument.
• Do NOT pry containers, puncture packages, or lift food
items with the probe.
• Do NOT expose the thermometer body to temperatures
above 122°F (50°C).
• Do NOT expose the tip or probe shaft to temperatures
above 572°F (300°C).
• Do NOT stab, jab, or force probe tip into any solid
medium. Do NOT force probe tip into frozen food.
• Do NOT allow oils or food to collect on thermometer
body. Clean frequently with sanitizing wipe.
GUARANTEE - This instrument carries a two-year
warranty against defects in either components or
workmanship. During this period, products that prove
to be defective will, at the discretion of ThermoWorks,
be either repaired or replaced without charge. This
warranty does not apply to probes, where a six-month
period is offered. Full details of liability are available
within ThermoWorks’ Terms & Conditions of Sale at
www.thermoworks.com/product-warranty.
The Bluetooth®word mark and logos are registered
trademarks owned by Bluetooth SIG, Inc. and any use of
such marks by ThermoWorks is under license.
Google Play and the Google Play logo are trademarks of
Google Inc. Android is a trademark of Google Inc.
Apple, the Apple logo, iPhone, and iPod touch are
trademarks of Apple Inc., registered in the U.S. and other
countries. App Store is a service mark of Apple Inc.,
registered in the U.S. and other countries.
iOS is a trademark or registered trademark of Cisco in the
U.S. and other countries and is used under license.