15
1. Application
The MultiSafe DSP-UB 3 is a two-pole voltage tester
to test on railway lines with lateral power supply
(3rd-rail). Thanks to its green and red LEDs, the
display is easy to see even in dark surroundings.
The rmly attached magnet and the extension
allowing greater safety distances and ease of
handling.
With the MultiSafe DSP-UB 3 you can test within
the specied nominal voltage range of 10 to 3000
V DC and 10 to 3000 V AC voltages. The integrated
self-test enables the function to be checked on site.
Thanks to its high degree of protection (IP65) the
MultiSafe DSP-UB 3 may even be used in rain.
1.1 Intended use
This device is intended for use in applications as
described in the operating instructions only. Thus,
it is imperative to observe the notes on safety and
the technical data in conjunction with the ambient
conditions.
Any other form of usage is not permitted and can
lead to accidents or destruction of the unit.
Any misuse will result in the expiry of all guarantee
and warrantly claims.
2. Safety Precautions
When used for its intended purpose, the safety of
the operator, as well as that of the instrument, is
assured.
In order to maintain awless technical safety con-
ditions, and to assure safe use, it is imperative that
you read these operating instructions thoroughly
and carefully before placing your instrument
into service, and that you follow all instructions
contained therein.
Observe the following safety precautions:
The voltages indicated on the MultiSafe are
rated voltages. The voltage tester may only be
used in systems working within these rated
voltage ranges.
Faultless indication of display values is only
guaranteed between -15° and +55°C.
Hold the instrument by the handgear only, to
avoid covering the display and not touching the
test electrode.
The test probe may only be connected up to
the red limiting mark to live plant components.
The maximum on-period is 120 seconds.
Only qualified persons may carry out work with
these device. The user needs to be farmiliar with
the risks for measuring voltage and compliance
with safety regulations and the proper use of the
voltage detector.
The voltage tester may only be dismantled by
authorised personnel.
The grp-extension of the voltage tester must not
to be removed. It must be mounted on the
display unit of the DSP UB 3. The tester cannot
be used without the grp-extension.