Transition Networks SISPM1040-582-LRT Quick Start Guide
33754 Rev. C https://www.transition.com Page 1of 2
SISPM1040-582-LRT
Managed Hardened PoE++ Switch (8) 10/100/1000Base-T
PoE++ Ports + (2) 100/1000Base-X SFP Slot
Quick Start Guide
See the
Install
Guide
for important Cautions and Warnings, Features, Specs, Back and
Front Panel, LEDs, DIP Switch Settings, RESET button, Installation, Mounting, Installing
SFPs, Connecting Devices, DI/DO Relay, Grounding, Connecting P1 and P2, Power
Supply, Initial Config, Troubleshooting, Warranty, PoE Modes, Compliance, and Tech Support.
Warning and Caution - Proper Installation and Operation (English): These devices are open-type devices that are to be installed in an
enclosure only accessible with the use of a tool, suitable for the environment. This equipment is suitable for use in Class I, Division 2,
Groups A, B, C, and D or non-hazardous locations only. WARNING –EXPLOSION HAZARD. DO NOT DISCONNECT WHILE THE CIRCUIT
IS LIVE OR UNLESS THE AREA IS FREE OF IGNITIBLE CONCENTRATIONS.
Avertissement et mise en garde - Installation et fonctionnement corrects (français): Ces périphériques sont des périphériques de
type ouvert qui doivent être installés dans un enceinte uniquement accessible à l'aide d'un outil, adapté à environnement.
Cet équipement peut être utilisé dans la classe I, division 2, groupes A, B, C, et D ou des emplacements non dangereux seulement.
AVERTISSEMENT - RISQUE D'EXPLOSION. NE PAS SE DÉCONNECTER LORSQUE LE CIRCUIT EST VIVANT OU À MOINS QUE LA ZONE NE
SOIT LIBRE DE CONCENTRATIONS IGNIFIABLES.
Package Contents: Verify you received one Switch with Terminal Block attached, one Power Supply (separate package),
one DB-9 to RJ-45 Cable, four adhesive rubber feet, one Printed Quick Start Guide, and one DIN Rail mounting kit.
Front Panel: The SISPM1040-582-LRT front panel ports, LEDs, Power Input terminal block, DI/DO terminal block,
CONSOLE port, DIP Switch, RESET button, and Ground screw are shown and described below.
LED Indicators: The front panel LEDs provide switch and Ring status. Power LEDs indicate if the switch is powered up
correctly. System LED: indicates if the system is ready or not ready. Alarm LED indicates if the system is normal or not.
Ring Master LED and Rapid Chain LED indicate if the Rapid Ring is ready or not ready. Port Status LEDs indicate the
current status of each port. See the
Install
Guide
for details.
DIP Switch for Ring Settings: The two-position DIP switch is labeled RC (1) (Rapid Chain) and RM (2) (Ring
Master). The DIP switch lets you avoid having to access the Web UI or CLI to configure a ring. See the
Install
Guide
for DIP switch setting details.
RESET Button: To reset the switch press RESET for 2~7 seconds; the SYS LED blinks green; Port status LEDs are Off.
To restore to defaults, press RESET for 7~12 seconds; the SYS LED blinks green; Port status LEDs are all ON.
Installation: Caution: The switch is an indoor device. If used with outdoor devices such as outdoor IP cameras or
outdoor Wi-Fi APs, then it is strongly suggested to install a surge protector or surge suppressor to protect the switch.
Compliant with 802.3at in Environment A when using an isolated power supply. For other apps, see the
Install
Guide
.
These devices are open-type devices that are to be installed in an enclosure only accessible with the use of a tool, suitable for the
environment. This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous locations only.
“WARNING – EXPLOSION HAZARD. DO NOT DISCONNECT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS FREE OF IGNITIBLE
CONCENTRATIONS. Temperature code (T-Code) –T4.
Warning: Turn the power off before connecting or disconnecting modules or wires. The correct power supply
voltage is listed on the product label. Check the voltage of your power source to make sure that you are using
the correct voltage. Do NOT use a voltage greater than what is specified on the product label.
PoE++ Power Note: The Meanwell 25160 (and other) power supplies are shipped set to 48VDC. If you unbox the PS, plug it into the
SISPM1040-582-LRT and then connect 60W cameras to the switch, the cameras may not power up by POE. The SISPM1040-582-LRT
needs 52-57VDC to power all 8 ports. You must use a small Phillips screwdriver to turn the PS potentiometer up to 52-57VDC.
Note: Meanwell 25160 power supplies shipped after Sept. 2019 have the default setting changed from 48vdc to 54vdc to provide for
additional power required in POE++ environments.