Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 |
[email protected] | www.turck.com
1|
4RU130U-M18E-LI8X2-H1151 | 05-04-2022 12-07 | Technical modifications reserved
RU130U-M18E-LI8X2-H1151
Ultrasonic Sensor – Diffuse Mode Sensor
Technical data
Type RU130U-M18E-LI8X2-H1151
ID 1610089
Ultrasonic data
Function Proximity switch
Range 150…1300mm
Resolution 1 mm
Minimum measuring range 100mm
Minimum switching range 100mm
Ultrasound frequency 200kHz
Repeat accuracy ≤0.15% of full scale
Temperature drift ±1.5% of full scale
Linearity error ≤ ±0.5%
Edge lengths of the nominal actuator 100mm
Approach speed ≤10m/s
Pass speed ≤2m/s
Electrical data
Operating voltage 15…30VDC
Residual ripple 10% Uss
DC rated operational current ≤150mA
No-load current ≤50mA
Load resistance ≤1000Ω
Response time typical <90ms
Readiness delay ≤300ms
Output function Analog output
Output 1 Analog output
Current output 4…20mA
Features
■Smooth sonic transducer face
■Cylindrical housing M18, potted
■Connection via M12 x 1 male
■Teach range adjustable via adapter
■Temperature compensation
■Blind zone: 15cm
■Range: 130cm
■Resolution: 1mm
■Aperture angle of sonic cone: ±16 °
■Analog output, 4…20mA, additional switch-
ing output, PNP
Wiring diagram
Functional principle
Ultrasonic sensors capture a multitude of
objects contactlessly and wear-free with
ultrasonic waves. It does not matter whether
the object is transparent or opaque, metallic
or non-metallic, firm, liquid or powdery. Even
environmental conditions such as spray, dust
or rain hardly affect their function.
The sonic cone diagram indicates the
detection range of the sensor. In accordance
with standard EN 60947-5-7, quadratic targets
in a range of sizes (20×20 mm, 100×100
mm) and a round rod with a diameter of
27mm are used.
Important: The detection ranges for other
targets may differ from those for standard
targets due to the different reflection
properties and geometries.