PAGE 2 OF 3 0515 IH-2715
SET UP
WARNING! Verify that the AC Adapter input
voltage matches the local AC power supply.
Use the scale only in dry locations. For best
results, use the scale in the specified optimum
operating temperature. Do not operate the
scale in hostile or unstable environments. Use
the scale with care, gently loading items to be
weighed onto the center of the pan. Avoiding
rough treatment will aid in the life of your scale.
INSTALLING THE PLATFORM
1. Place the stainless steel pan onto the weighing
platform. (See Figure 1)
CONNECTING POWER
BATTERY
1. Remove the battery cover on the bottom of the scale.
2. Place 3 "AA" size batteries into the compartment.
CAUTION! Do not use excessive force or press
on the weighing pan.
3. Re-insert the battery cover.
AC POWER
1. Connect the AC adapter to the receptacle at the
rear of the scale.
2. Plug the AC adapter into a properly grounded
electrical outlet.
Figure 1
OPERATION
POWER UP TEST
When the scale is turned on, all display segments will
be displayed for a few seconds, indicating that the unit
is self adjusting to zero. Once the "0" is displayed, the
scale is ready for use.
STABLE READING INDICATION
A star indicator will appear in the lower left corner of the
display when a stable reading has been reached.
OVERLOAD
If the applied load exceeds the capacity of the scale,
an "E" will appear on the display and the load should
be removed immediately. The scale will return to normal
operation.
TARE FUNCTION
Values can progressively be added to a sample. By
pressing the
ON/OFF ZERO
button, the scale display
returns to zero. After adding additional mass, press
ON/OFF ZERO
to zero the scale again. Additional mass
may be added up to the capacity of the scale.
NEGATIVE VALUE
When a load is removed from the scale, any zeroed
value will be displayed as a negative number. To
return to normal operation, the zeroed value can be
cancelled by pressing
ON/OFF ZERO
button.