EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. U-Line
  6. •
  7. Scale
  8. •
  9. U-Line H-670 User manual

U-Line H-670 User manual

Other manuals for H-670

1

This manual suits for next models

3

Other U-Line Scale manuals

U-Line OHAUS CS H-2715 User manual

U-Line

U-Line OHAUS CS H-2715 User manual

U-Line H-9554 Installation and operating manual

U-Line

U-Line H-9554 Installation and operating manual

U-Line SCOUT PRO H-2709 User manual

U-Line

U-Line SCOUT PRO H-2709 User manual

U-Line ADVENTURER PRO Series User manual

U-Line

U-Line ADVENTURER PRO Series User manual

U-Line H-10903 User manual

U-Line

U-Line H-10903 User manual

U-Line H-1671 User manual

U-Line

U-Line H-1671 User manual

U-Line H-3478 User manual

U-Line

U-Line H-3478 User manual

U-Line H-8109 User manual

U-Line

U-Line H-8109 User manual

U-Line H-3677 User manual

U-Line

U-Line H-3677 User manual

U-Line H-1121 User manual

U-Line

U-Line H-1121 User manual

U-Line H-2382 User manual

U-Line

U-Line H-2382 User manual

U-Line H-4602 User manual

U-Line

U-Line H-4602 User manual

U-Line H-103 User manual

U-Line

U-Line H-103 User manual

U-Line H-1679 User manual

U-Line

U-Line H-1679 User manual

U-Line H-5275 User manual

U-Line

U-Line H-5275 User manual

U-Line H-479 User manual

U-Line

U-Line H-479 User manual

U-Line H-670 User manual

U-Line

U-Line H-670 User manual

U-Line H-5819 User manual

U-Line

U-Line H-5819 User manual

U-Line H-5819 User manual

U-Line

U-Line H-5819 User manual

U-Line H-3478 User manual

U-Line

U-Line H-3478 User manual

U-Line CS Series User manual

U-Line

U-Line CS Series User manual

U-Line SCOUT H-9560 User manual

U-Line

U-Line SCOUT H-9560 User manual

U-Line H-4602 User manual

U-Line

U-Line H-4602 User manual

U-Line H-5836 User manual

U-Line

U-Line H-5836 User manual

Popular Scale manuals by other brands

Omron HN-286 null

Omron

Omron HN-286 null

AWS ZEO-50 user manual

AWS

AWS ZEO-50 user manual

Gima Glass Body Fat Analyzer Use and maintenance book

Gima

Gima Glass Body Fat Analyzer Use and maintenance book

Seca 374 user manual

Seca

Seca 374 user manual

TEC TEC SL59 SERIES owner's manual

TEC

TEC TEC SL59 SERIES owner's manual

Axis B/E Series user manual

Axis

Axis B/E Series user manual

Alecto ACW-40 user manual

Alecto

Alecto ACW-40 user manual

Rice Lake MSI-4260 IS Technical manual

Rice Lake

Rice Lake MSI-4260 IS Technical manual

IKA RCT basic safety control operating instructions

IKA

IKA RCT basic safety control operating instructions

ADE M20011 operating manual

ADE

ADE M20011 operating manual

Duronic KS3000 manual

Duronic

Duronic KS3000 manual

Digi SM-720 Service manual

Digi

Digi SM-720 Service manual

Cardinal CS Series Operation manual

Cardinal

Cardinal CS Series Operation manual

Korona Kastella Instructions for use

Korona

Korona Kastella Instructions for use

A&D FC-50Ki instruction manual

A&D

A&D FC-50Ki instruction manual

BDA CAMARGUE installation guide

BDA

BDA CAMARGUE installation guide

Tanita HD-357 Instructions for use

Tanita

Tanita HD-357 Instructions for use

Leifheit 03173 quick start guide

Leifheit

Leifheit 03173 quick start guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

PAGE 1 OF 4 0114 IH-670
INDUSTRIAL PLATFORM
SCALE
1-800-295-5510
uline.com
πH-670, H-747
H-794, H-4593
1. Remove scale parts from packaging.
2. Lift the Scale Pan off the Platform Base.
3. Remove the four styrofoam blocks from the Platform
Base. (See Figure 1)
4. Replace the Scale Pan.
Figure 1
Allen Wrench Power Cord Support Bracket Tower Platform Base Display Indicator
PARTS
ASSEMBLY INSTRUCTIONS
PAGE 2 OF 4 0114 IH-670
ASSEMBLY INSTRUCTIONS CONTINUED
5. Place the Scale on the stable, level surface on which
it is intended to be used.
6. Using the bubble level on the Base Bracket as a
guide, adjust the four leveling feet until scale is level.
(See Figure 2)
7. Feed the data cable from the Base Bracket through
the Tower. (See Figure 3)
8. Tighten the Base Bracket using the included Allen
Wrench. (See Figure 4)
9. Feed the data cable through the Support Bracket by
unscrewing the knob and pulling the Support Bracket
pieces apart. (See Figure 5)
10. Once data cable is threaded through Support
Bracket as shown, tighten the knob and place the
Support Bracket on the Tower. (See Figure 5)
11. Tighten the bolt at the base of the Support Bracket.
(See Figure 5)
12. Slide the Display Indicator onto the Support Bracket.
Adjust the angle of the display by loosening the
knob on the Support Bracket. Tighten the knob when
finished adjusting the angle. (See Figure 6)
13. Plug the data cable and the Power Cord into the
Display Indicator. (See Figure 7)
Figure 2
Figure 4
Figure 5
Figure 3
Figure 6
Figure 7
PAGE 3 OF 4 0114 IH-670
STABLE M+ Pcs
Pcs Kg
0CE
TR
CE
STABLE PT M+
M+
Pcs
UNITS
0R
Pcs
PT
T
charging
H-670
H-747 & H-7914
QUICK USER’S GUIDE
COUNTING FUNCTION
•Prior to use, connect the AC
adapter and monitor cable.
•This scale has fixed samples
of 10, 20, 50, and 100 pieces.
•The larger sample sizes will
provide you with a more
accurate unit weight.
1. Prior to placing any object
onto the scale, press the CE
key (1). (See Figure 8)
2. Select the fixed sample key of
10, 20, 50, 100 pieces (2).
(See Figure 8)
3. Place the requested number
of samples onto the scale.
4. Press the count key (4).
(See Figure 8)
5. Remove all parts from the
scale.
6. Place the desired number of
pieces onto the scale. This will
provide an accurate count
reading.
7. Remove all parts from the
scale.
8. For the H-670 and H-4593:
Press the UNITS key (8) to
return to the weight display
screen. (See Figure 8)
9. For the H-747 and H-794:
Press the KG key (8) to return
to the weight display screen.
(See Figure 8)
Figure 8
H-670 & H-4593
H-747 & H-794
PAGE 4 OF 4 0114 IH-670
CALIBRATION INSTRUCTIONS
NOTE: Scale can only be accurately calibrated using standard calibrated scale weights. Using
non-calibrated weights may result in inaccurate scale calibration. Nothing should be on the scale and
scale should be level.
ACTIVATE WEIGHT CALIBRATION MODE
•Turn on the scale. As scale counts down to zero, press and hold the Zero key until 02001 appears in the
display.
•Release Zero key. F0 appears in display.
•Switch the mini jumper SWA1 to “ADJ” position. Adjust is down; Lock is up. The switch is located under a
panel on the right side of the keypad housing.
•Press Enter key. Display shows ZEro.
•Press Enter key. Display shows 0---,-Ckg.
•Press UNITS or Kg key to set scale to lb or kg as needed.
•Use the Up and Enter keys to preset the weight being used to calibrate the scale. The Up key sets the
number and the Enter key moves right one digit. Example: to set a weight of 3.0 kg you would press the
Enter key three times to move right three spaces and the Up key three times to enter the number 3.
•Place your calibrated weight on the scale. Display shows WAIt.
•Scale displays weight and beeps.
•Scale is calibrated, it will now return to weighing mode automatically.
•Switch the mini jumper SWA1 back to “LOCK.”
0
UNITS
Kg
0
UNITS
Kg
0
UNITS
Kg
0
UNITS
Kg
0
UNITS
Kg
0
UNITS
Kg
0
UNITS
Kg
0
UNITS
Kg
πCHICAGO•ATLANTA•DALLAS•LOSANGELES•MINNEAPOLIS•NYC/PHILA•SEATTLE•MEXICO•CANADA
1-800-295-5510
uline.com