manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ubiquiti
  6. •
  7. Switch
  8. •
  9. Ubiquiti ES-48-500W User manual

Ubiquiti ES-48-500W User manual

EdgeSwitch Mounting Screws (Qty. 4) Cage Nuts (Qty. 4)
Power Cord
Package Contents
Installation Requirements
Phillips screwdriver
Standard-sized, 19" wide rack with a minimum of 1U height available
For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
For outdoor applications, shielded Category 5 (or above) cabling should be used for all
wired Ethernet connections and should be grounded through the AC ground of the power
supply.
We recommend that you protect your networks from harmful outdoor environments and
destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For
more details, visit:
ui.com/toughcable
Note:
Although the cabling can be located outdoors, the EdgeSwitch itself should
be housed inside a protective enclosure.
Hardware Overview
ES-48-500W, ES-48-750W Quick Start Guide
System LED
RJ45 PoE LED (Ports 1 - 48)
RJ45 Speed/Link/Activity LED (Ports 1 - 48)
Note:
The System LED functionality has been updated with rmware v1.8.0. We
recommend that you update the EdgeSwitch to the latest rmware.
Flashing White Bootup in progress.
White Ready for use, not connected to Ubiquiti® Network
Management System (UNMS™). See
“UNMS
Management”
.
Blue Ready for use, connected to UNMS.
Steady Blue with Occasional
Flashing Ready for use, unable to connect to UNMS, check
connection to UNMS server.
Quickly Flashing Blue Used to locate a device in UNMS.
Alternating
Blue/White Firmware upgrade in progress.
Off No PoE
Amber IEEE 802.3af/802.3at
Green 24V Passive
Off No Link
Amber Link Established at 10/100 Mbps
ES-48-500W, ES-48-750W Quick Start Guide
SFP+ Speed/Link/Activity LED (Ports 1 - 2)
SFP Speed/Link/Activity LED (Ports 1 - 2)
RJ45 (Ports 1 - 48)
SFP+ (Ports 1 - 2)
SFP (Ports 1 - 2)
Reset Button
Console Port
Power Port
Flashing Indicates Activity
Green Link Established at 1000 Mbps (1 Gbps)
Flashing Indicates Activity
Off No Link
Green Link Established at 1 Gbps
Flashing Indicates Activity
White Link Established at 10 Gbps
Flashing Indicates Activity
Off No Link
Green Link Established at 1 Gbps
Flashing Indicates Activity
RJ45 ports support Power over Ethernet (PoE) and 10/100/1000 Ethernet connections.
Hot-swappable SFP+ ports support 1/10 Gbps connections.
Hot-swappable SFP ports support 1 Gbps connections.
Click here
to learn how to reset an EdgeSwitch to factory defaults.
RJ45 serial console port for Command Line Interface (CLI) management.
Connect the included Power Cord to the Power port.
Hardware Installation
1.
ES-48-500W, ES-48-750W Quick Start Guide
2.

OR
ES-48-500W, ES-48-750W Quick Start Guide
3.
Connecting Ethernet
ES-48-500W, ES-48-750W Quick Start Guide
Note:
The PoE settings for ports 1-48 are set to PoE+ auto by default, so 802.3af/at
devices can be plugged in and automatically receive PoE. For instructions on how to
enable 24V passive PoE, refer to
“Conguring PoE Settings”
.
Connecting SFP+/SFP
These ports support the specied module types at the following speeds:
Ports SFP+ Module Type SFP Module Type
SFP+ 1-2 10 Gbps 1 Gbps
SFP 1-2 (Not supported) 1 Gbps
1.
2.
ES-48-500W, ES-48-750W Quick Start Guide
3.
For information about compatible ber SFP+ or SFP modules, visit:
ubnt.link/SFP_DAC_Compatibility
Accessing the Conguration Interface
The EdgeSwitch is set to DHCP by default, so it will try to automatically obtain an IP address. If
that fails, then it will use the default fallback IP address, 192.168.1.2. Proceed to the
appropriate section, DHCP or
“Fallback IP Address”
:
DHCP
Use one of the following methods:
Set up the DHCP server to provide a specic IP address to the EdgeSwitch based on its
MAC address (on the label).
Let the EdgeSwitch obtain an IP address and then check the DHCP server to see which IP
address was assigned.
ES-48-500W, ES-48-750W Quick Start Guide
To log in, follow these steps:
1. Launch your web browser. Type the appropriate IP address in the address eld. Press enter
(PC) or return (Mac).
2. Enter ubnt in the Username and Password elds. Click Sign In.
3. The EdgeSwitch Conguration Interface will appear. Customize additional settings as
needed.
For more information on PoE conguration, refer to
“Conguring PoE Settings”
. For more
information, refer to the EdgeSwitch documentation, which is available at
ui.com/download/edgemax
Fallback IP Address
1. Ensure that your computer (or other host machine) is connected to the EdgeSwitch.
2. Congure the Ethernet adapter on your host system with a static IP address on the
192.168.1.x subnet.
3. Launch your web browser. Type the appropriate IP address in the address eld (192.168.1.2
is the default fallback IP address). Press enter (PC) or return (Mac).
ES-48-500W, ES-48-750W Quick Start Guide
4. Enter ubnt in the Username and Password elds. Click Sign In.
5. The EdgeSwitch Conguration Interface will appear. Go to Settings .
6. Change the IP Address to a unique IP address. Click Apply.
ES-48-500W, ES-48-750W Quick Start Guide
Note:
If you change the IP settings, then the session will be cut off, and you will need
to reconnect to the EdgeSwitch using the new IP address.
Customize additional settings as needed. For more information on PoE conguration, refer to
“Conguring PoE Settings”
.
UNMS Management
You can manage your device using UNMS, which lets you congure, monitor, upgrade, and
back up your devices using a single application. Get started at
www.unms.com
Conguring PoE Settings
The PoE settings for ports 1-48 are set to PoE+ by default, so 802.3af/at devices can be
plugged in and automatically receive PoE.
WARNING:
Before activating 24V passive PoE, ensure that the connected device
supports PoE and the supplied voltage.
1. Go to Dashboard .
2. For the Ethernet port you want to congure, click the PoE drop-down menu.
ES-48-500W, ES-48-750W Quick Start Guide
3. Select the appropriate mode: Off, 24V, or PoE+.
For more information, refer to the EdgeSwitch documentation, which is available at
ui.com/download/edgemax
Specications
ES-48-500W/ES-48-750W
Dimensions 485 x 43.7 x 374.6 mm (19.09 x 1.72 x 14.75")
Weight
ES-48-500W 6.1 kg (13.5 lb)
ES-48-750W 6.5 kg (14.3 lb)
Total Non-Blocking Line Rate 70 Gbps
Max. Power Consumption
ES-48-500W 500W
ES-48-750W 750W
Power Method 100-240VAC/50-60 Hz, Universal Input
Power Supply
ES-48-500W AC/DC, Internal, 500W DC
ES-48-750W AC/DC, Internal, 750W DC
LEDs Per Port
Serial Console Port N/A
RJ45 Data Ports PoE, Speed/Link/Activity
SFP Data Ports Speed/Link/Activity
Interfaces
Networking Interfaces (48) 10/100/1000 Mbps RJ45 Ethernet Ports
(2) 1/10 Gbps SFP+ Ethernet Ports
(2) 1 Gbps SFP Ethernet Ports
Management Interface (1) RJ45 Serial Port, Ethernet In/Out Band
Rack-Mount Yes, 1U High
ESD/EMP Protection Air: ± 24 kV, Contact: ± 24 kV
ES-48-500W, ES-48-750W Quick Start Guide
ES-48-500W/ES-48-750W
Shock and Vibration ETSI300-019-1.4 Standard
Operating Temperature -5 to 40° C (23 to 104° F)
Operating Humidity 5 to 95% Noncondensing
Certications CE, FCC, IC
PoE Per Port
PoE Interfaces POE+ IEEE 802.3af/at (Pins 1, 2+; 3, 6-)
24VDC Passive PoE (Pins 4, 5+; 7, 8-)
Max. PoE+ Wattage per Port by PSE 34.2W
Voltage Range 802.3at Mode 50-57V
Max. Passive PoE Wattage per Port 17W
24V Passive PoE Voltage Range 20-27V
Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories specied by the manufacturer.
WARNING:
Failure to provide proper ventilation may cause re hazard. Keep at least 20 mm of
clearance next to the ventilation holes for adequate airow.
WARNING:
To reduce the risk of re or electric shock, do not expose this product to rain or
moisture.
WARNING:
Do not use this product in location that can be submerged by water.
WARNING:
Avoid using this product during an electrical storm. There may be a remote risk of
electric shock from lightning.
Electrical Safety Information
1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the
manufacturer’s label. Connection to a different power source than those specied may result in
improper operation, damage to the equipment or pose a re hazard if the limitations are not followed.
2. There are no operator serviceable parts inside this equipment. Service should be provided only by a
qualied service technician.
3. This equipment is provided with a detachable power cord which has an integral safety ground wire
intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that is not the provided approved type. Never use an
adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
b. The equipment requires the use of the ground wire as a part of the safety certication, modication
or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualied electrician or the manufacturer if there are questions about the installation prior
to connecting the equipment.
ES-48-500W, ES-48-750W Quick Start Guide
d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate
short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where
applicable, specify arbitration instead of jury trials or class actions.
Compliance
FCC
Changes or modications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operations of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this
equipment may cause radio interference.
CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable
to it.
WEEE Compliance Statement
Declaration of Conformity
ES-48-500W, ES-48-750W Quick Start Guide
Online Resources
© 2020 Ubiquiti Inc. All rights reserved.
ES-48-500W, ES-48-750W Quick Start Guide

Other manuals for ES-48-500W

2

This manual suits for next models

1

Other Ubiquiti Switch manuals

Ubiquiti UniFi US-8-60W User manual

Ubiquiti

Ubiquiti UniFi US-8-60W User manual

Ubiquiti EdgeSwitch 8 150W User manual

Ubiquiti

Ubiquiti EdgeSwitch 8 150W User manual

Ubiquiti US-XG-6POE User manual

Ubiquiti

Ubiquiti US-XG-6POE User manual

Ubiquiti EdgeSwitch 10 XP User manual

Ubiquiti

Ubiquiti EdgeSwitch 10 XP User manual

Ubiquiti TS-5-POE ToughSwitchPoE User manual

Ubiquiti

Ubiquiti TS-5-POE ToughSwitchPoE User manual

Ubiquiti EdgeSwitch ES-16-XG User manual

Ubiquiti

Ubiquiti EdgeSwitch ES-16-XG User manual

Ubiquiti TS-5-POE ToughSwitchPoE User manual

Ubiquiti

Ubiquiti TS-5-POE ToughSwitchPoE User manual

Ubiquiti USW--Pro--48 User manual

Ubiquiti

Ubiquiti USW--Pro--48 User manual

Ubiquiti ES-48-500W User manual

Ubiquiti

Ubiquiti ES-48-500W User manual

Ubiquiti EdgeSwitch 16 XG User manual

Ubiquiti

Ubiquiti EdgeSwitch 16 XG User manual

Ubiquiti mFi-LD User manual

Ubiquiti

Ubiquiti mFi-LD User manual

Ubiquiti EdgeSwitch ES-10XP User manual

Ubiquiti

Ubiquiti EdgeSwitch ES-10XP User manual

Ubiquiti US-16-XG User manual

Ubiquiti

Ubiquiti US-16-XG User manual

Ubiquiti UniFi USW-Pro-48-POE User manual

Ubiquiti

Ubiquiti UniFi USW-Pro-48-POE User manual

Ubiquiti UniFi USW-Pro-24-POE User manual

Ubiquiti

Ubiquiti UniFi USW-Pro-24-POE User manual

Ubiquiti UniFi US-48-500W User manual

Ubiquiti

Ubiquiti UniFi US-48-500W User manual

Ubiquiti US-48 User manual

Ubiquiti

Ubiquiti US-48 User manual

Ubiquiti UnFi US-8-60W User manual

Ubiquiti

Ubiquiti UnFi US-8-60W User manual

Ubiquiti ES-10X User manual

Ubiquiti

Ubiquiti ES-10X User manual

Ubiquiti UniFi USW-Industrial User manual

Ubiquiti

Ubiquiti UniFi USW-Industrial User manual

Ubiquiti US-24 User manual

Ubiquiti

Ubiquiti US-24 User manual

Ubiquiti US-16-XG User manual

Ubiquiti

Ubiquiti US-16-XG User manual

Ubiquiti EdgeSwitch 16XP User manual

Ubiquiti

Ubiquiti EdgeSwitch 16XP User manual

Ubiquiti UniFi US-48-500W User manual

Ubiquiti

Ubiquiti UniFi US-48-500W User manual

Popular Switch manuals by other brands

DeviceWell HDS9125 user manual

DeviceWell

DeviceWell HDS9125 user manual

IMC Networks iMcV-Giga-FiberLinX-II Operation manual

IMC Networks

IMC Networks iMcV-Giga-FiberLinX-II Operation manual

Extractor Corporation SUITMATE ADJUSTMENT PROCEDURE

Extractor Corporation

Extractor Corporation SUITMATE ADJUSTMENT PROCEDURE

Raritan Dominion KX II user guide

Raritan

Raritan Dominion KX II user guide

Generac Power Systems TRANSFER SWITCH Warranty information booklet

Generac Power Systems

Generac Power Systems TRANSFER SWITCH Warranty information booklet

Larson Electronics EPS-2XPB-SG-DPMS Operation manual

Larson Electronics

Larson Electronics EPS-2XPB-SG-DPMS Operation manual

MaxLux МХ0048 quick start guide

MaxLux

MaxLux МХ0048 quick start guide

pathway eDIN 1016 manual

pathway

pathway eDIN 1016 manual

steute Ex 61 Z Mounting and wiring instructions

steute

steute Ex 61 Z Mounting and wiring instructions

TRENDnet TEG-224WS - DATA SHEETS Quick installation guide

TRENDnet

TRENDnet TEG-224WS - DATA SHEETS Quick installation guide

Exsys EX-1188HMS-2 manual

Exsys

Exsys EX-1188HMS-2 manual

Avaya 5900 Series Installation Job Aid

Avaya

Avaya 5900 Series Installation Job Aid

D-Link DES-5024 - Switch Application notes

D-Link

D-Link DES-5024 - Switch Application notes

NETGEAR GSM7328Sv1 - ProSafe 24+4 Gigabit Ethernet L3 Managed Stackable... Cli manual

NETGEAR

NETGEAR GSM7328Sv1 - ProSafe 24+4 Gigabit Ethernet L3 Managed Stackable... Cli manual

Niles SPK-1 operating instructions

Niles

Niles SPK-1 operating instructions

Unipoe 16GE+2G SFP user guide

Unipoe

Unipoe 16GE+2G SFP user guide

Compaq Memory Channel Hub Installation

Compaq

Compaq Memory Channel Hub Installation

Kathrein EXR 1942 instructions

Kathrein

Kathrein EXR 1942 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.