INTRODUCTION
Uni-ram holds many patents on designs used in its innovative products. Every machine is tested
for compliance with Quality Assurance standards. Follow the directions in this manual under Setup,
Operation and Maintenance in order to operate this machine safely and effectively. Not following these
instruction can lead to malfunction or damage to the machine. Ensure that the manual is readily avail-
able for the operator at all times. If you have any questions about the operation of this machine, call your
Distributor or Uni-Ram Service Engineer at 1-800-417- 9133.
MODELS
MODEL VENTING AIR RINSE AIR PURGE
UG2000DM NO NO ONE
UG2000DMV YES YES TWO
COMMON FEATURES
• Automatic Wash
• Clean 2 Spray Guns and 2 Pots at the same time.
• 14 Cleaning Jets with swirl action.
• Flow-through Brush operated by a foot pedal.
• Shipping Size and Weight: 28" W x 17" D x 42" H, 91 LBS 41 KG.
UG2000DMV has is the same features as the UG2000DM with the additional feature of venting.
Raising the lid initiates the venting system and removes fumes from the cleaning tank for the health
of the operator.
CAUTIONS AND WARNINGS
• Always disconnect this machine from power sources before performing maintenance.
• Do not smoke or use near open flames, sparks or heat.
• Make sure all ground wires are connected and that unit itself is grounded properly.
SAFETY EQUIPMENT
• Wear safety eyeware, respiratory protection and protective clothing.
• Wear deluxe extended length neoprene gloves; SAS PN 6588 or Thicksters PN 6602-20 through
6605-20.
SETUP
DELIVERY INSPECTION
• Inspect the shipping carton for any sign of transport damage. Carefully remove the unit from the ship-
ping carton and check the unit for damage. Report any transport damage immediately to the carrier
and to Uni-ram Corporation. Initiate a freight claim with the carrier. The manufacturer is not respon-
sible for the freight damage.
Bag of accessories contains the following:
• Push on adapter for disposable cup (110-430PPS).
• Tapered plug (kit-plug) (150-231)
• Trigger lock spring and plug package (140-2340) (2 in a package).
VENTING
If you have the UG2000DMV connect the vent pipe to the ventilation system in the facility.

3
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
Drain Valve (inside)
Drain Hose
Suction hose for Wash
pail and suction hose for
brush
Wash Pail
Foot petal
for brush
Timer
UG2000DM
FIGURE 1
Cleaning Tank (inside)

4
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
UG2000DMV
Vent pipe
UG2000DMV has is the same features as the UG2000DM with the additional feature of
Venting:
Raising the lid initiates the venting system and removes fumes from the cleaning tank for
the health of the operator. The vent pipe is to be connected to the venting system in the
facility.
Air Rinse:
To evacuate the solvent from the spray gun.
Air Purge:
Use of Air Purge prevents solvent from reaching the air passage way of the spray gun.This
unit has 2 air purges.
Air Rinse

5
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
LOCATION
Position the unit in a well-ventilated area away from sparks, heat and open flames, at least 6 " from the
back wall.
AIR SUPPLY
• Connect a male air supply adapter (not supplied) into the female Air Inlet on the unit. The male air
supply adapter is 1/4" NPT.
• Connect the female air supply hose to the adapter. The air supply hose must be at least 3/8"
inside diameter. The air supply pressure must be at least 85 PSI and the sup-
ply air must be free from contaminants such as water, dust, rust, tar and
grease. If the air supply is not clean and dry install a moisture filter. The
operation and longevity of the pump and other components depends on
clean dry supply air.
• To prevent damage to the Diaphragm Pump an internal Air Pressure Regulator has been
installed to limit the air pressure to 85 PSI. Do not install a second air pressure regulator or use a
pressure set below 85 PSI.
GROUNDING
• Connect the green ground wire at the back of the unit to a ground in the building.
Note: The pump and metal tube that inserts into each pail are grounded.
SOLVENT SELECTION
The adhesion quality of automotive paint has dramatically improved in recent years. The choice of sol-
vent is critical. Only use good quality solvent that is formulated for your paint and intended for use with
automatic spray guns cleaners. DO NOT USE CHLORINATED SOLVENT.
PAIL SETUP
• Place the suction hose and drain hose in the solvent pail.
• Open the drain valve (vertical position).
• Pour 5 gallons of solvent in the wash tank to drain to the wash pail underneath.
Ring Terminal
DRAIN VALVE IS OPEN
(HANDLE IN VERTICAL POSITION).
DRAIN VALVE IS CLOSED
(HANDLE IN HORIZONTAL POSITION).

6
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
PRE - CLEAN
• Disconnect the spray gun from the air hose.
• Remove disposable cup shown in A.
• Squirt solvent into disposable cup adapter, shown in B photo.
• Pull the gun’s trigger to fl ush the solvent through the fl uid channel.
• Dispose of solvent in the waste container (not supplied).
• Do not mix water and solvent waste.
Disposable
Cup
A B
CLEANING SPRAY GUNS AND CUPS
• Remove digital air gauge if so equipped. A
• Loosen the air cap of the spray gun two full turns. B
• Lock the trigger in the open position with the Trigger Lock Spring. C
A B C

7
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
SPRAY GUN INSTALLED IN TANK
INSTALLING SPRAY GUNS IN TANK
• Place the spray gun on the nozzle with the cap facing the corner.
• Install Air Purge into the air passage way of the spray gun. (See photo above)
Nozzle Extension
for disposable cups
Location for Push On
Nozzle Extension
Caps points to
the corner jets
brush
Air Purge

8
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03

9
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
Prevent Solvent From Entering the Air Passage of Spray Gun:
insert the plastic plug into the air fi tting as in the photo
below . Positive air will fl ow through the passage way
to the cap during cleaning. If the air passage way has
a a male fi tting attach the knurled female nut to
prevent sovlent from entering the air passage way.
This fi tting is located on the chain with the
trigger clamp.
• Close the lid of the spray tank
and turn the "Auto Wash Timer"
clockwise as in photo below
to initiate cleaning. The wash
cycle takes about 60 seconds.
• MANUAL WASH
Open the lid and remove brush from its holder on the back wall of the wash tank.
Step on the foot pedal. A dedicated pump delivers wash solvent through the brush, left photo below.
To control the flow of solvent through the Brush, adjust the Flow Control, also on the front of the
unit, right photo.
• The spray gun can be washed with the brush before or after "Auto" wash.
• Dry the spray gun thoroughly.
REPLACING SOLVENT:
• Replace the solvent when the solvent has lost its cleaning
eff ectiveness or after approximately 100 cleanings.
• Close the drain valve (horizontal position).
• Remove the pail of used solvent. Dispose of the used solvent
in a manner compliant with the laws in the municipality.
Return the pail to the cabinet and install the suction hose and
drain hose to the pail. Pour 5 gallons of new clean solvent into the
cleaning tank to drain to the pail in the cabinet.
Plastic Plug insterted into the air
passage way of the spray gun
Drain Valve in
Closed Position

10
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
MAINTENANCE
• A removable screen fi lter is installed at the end of the suction pipe, in the wash pail. See the photos below.
• Once each week, remove the wash pail from the cabinet, remove the suction pipe with the pail, see photos
below, unscrew the metal fi lter ( see right photo below) and clean the fi lter in a cup of solvent.
Wash Pail Remove Suction Pipe and Filter Filter
REPLACING SOLVENT
• Replace the solvent when the solvent has lost cleaning eff ectiveness or after approximately 100 cleanings.
• Close the drain valve, see photo below. Remove the drain hose and suction pipe.
• Pour wash solvent from wash pail into waste drum, rinse out the pail. Replace the pail in the cabinet and
replace place the drain hose and suction hose. Open the drain valve. Pour 5 gallons (19 L) of fresh solvent in
the cleaning tank to fi ll the pail in the cabinet.
Drain Valve

11
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
TROUBLE SHOOTING

12
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03

13
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
TROUBLESHOOTING PROCEDURES PROCEDURE 1
Blocked Fluid Passage In Diaphagm Pump
If the pump sounds like it is working but liquid does not flow,
clear the fluid passage as follows:
• Remove suction tube from the pail and blow air at 85 PSI
into the INLET Liquid Hose (see diagram). Step on foot
pedal to activate pump. This procedure may have to be
repeated several times. If this procedure does not help,
blow some water into the suction hose using a spray gun,
wait one minute and step on foot pedal to activate pump.
This procedure may have to be repeated several times. If
this procedure does not work, the pump must be replaced.
If you need to replace the pump call the Uni-ram Service
Engineer. The warranty on the diaphragm pump is two
years from date of purchase.
This procedure will also clear a blockage in the fluid line for the brush. Follow the same procedure to
clear a blockage in the automatic nozzle except turn the timer instead of stepping on the foot pedal.
PROCEDURE 2
Blocked Air Passage In Diaphragm Pump
If there is a steady hissing sound and the pump is not
cycling, the spool valve has stalled due to a blocked air pas-
sage. Follow the procedure below to clear the blockage.
• Connect a blow gun to an 85 PSI source. Locate the
blue hose that extends from the air exhaust port of
the diaphragm pump. Use a blow gun to blow air into
the open end of this hose. Turn timer. If the procedure
is successful, the pump will start working. The proce-
dure may have to be repeated several times. If this
procedure does not work, replace the pump.
• Cause: Contaminants in the air supply (water, oil,
solid particles etc)
• Preventative Action: If necessary, install an Airline (Moisture) Filter.
PROCEDURE 3
Blocked Passage in Air Line
The components in the air line are the diaphragm pump, air valve, foot pedal, 3-way ball valve
and regulator. See the Flow Diagram and the section: Replacement Parts.
To troubleshoot a component:
1) Disconnect the air line to the component using the quick disconnect.
2) Step on foot pedal and check for presence of positive air pressure in the air line. If there is ample
positive air pressure, replace the component.
If air pressure is absent, there is a faulty component upstream. Reconnect the air line and check the
operation of the next component upstream by following steps 1 and 2 above.

14
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
UG2000DM FLOW DIAGRAM
Use the diagram to trace the fl ow of compressed air and solvent.

15
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
UG200DMV FLOW DIAGRAM
Use the diagram to trace the fl ow of compressed air and solvent.

16
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
REPLACEMENT PARTS
Part No. Description
110-430 Nozzle Adapter, Push On, Conventional Systems Only
110-430PPS Nozzle Adapter, Push On, Disposable and Conventional Systems
780-3530 Nozzle Adapter, Disposable Cup Systems Only
100-413F Paint Cap Holder
115-200/K Mechanical Timer Assembly, 5 minutes
140-230 Air Passage Plug
140-2340 Trigger Clamp & Plug Kit
113-800 Flow-Through Brush Assembly
100-8335 GROUND WIRE,14G, GREEN, 36" L
100-835 GROUND WIRE,18AWG, GREEN, 4 FT
UDP4TA DUAL DIAPHRAGM PUMP, 4"

17
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03

18
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
SERVICE PARTS UG2000DM
ITEM PartNo DESCRIPTION QTY
1 110-531L5 ADJUSTABLE FOOT 4
2 100-350N SPRAY JET ASSY.BRASS 8
3 100-370 SPRAY JET + EXTENSION 2
4 100-350L SPARY JET ASSY, 4
5 110-353 FITTING SET, INCLUDE 100-457& 110-356 1
6 780-3530 NOZZLE SUB ASSEMBLY, 3M PPS ADAPTOR 1
7 140-480 DRAIN VALVE WITH FITTINGS AND HOSE 1
8 100-332N FLAME RETARDING SCREEN 1
9 140-230 AIR PURGE KIT, SPRAY GUN 1
10 110-430 TAPER NOZZLE ADAPTER, 6.5” LG 1
11 110-430PPS NOZZLE ADAPTER FOR PPS, 6.5” 1
12 100-413F CUP HOLDER 2
13 140-2341 KIT-PLUG FOR GUN 2
14 110-430PPS2 UNIVERSAL NOZZLE ADAPTER , 3.25” 1
15 QCF901418 QC FITTING, ELBOW, 90° 1
16 102-3022F BRUSH HOLDER 1
17 144-390S MANUAL BRUSH 1
18 120-471 FITTING SET FOR SOLVENT BRUSH 1
19 100-820 PUSH ROD WITH GUIDE CLIP ASSY. 1
20 114-800V2 LID SWITCH WITH BRACKET, 4-W, 1-IN 2-OUT 1
21 100-835-6 GROUND WIRE ASSY, 18GA, 1300MM, GREEN 1
22 120-020PR AIR PRESSURE REGULATOR, SET TO 85 PSI 1
23 UDP4TA DUAL DIAPHRAGM PUMP, 4” 1
24 115-200K MECH. MANUAL TIMER KIT, 5 MINS. 1
25 120-4210TDM SUCTION TUBE ASSY WITH FILTER 1
26 104-4206 FILTER W/FITTING SUB-ASSY, SS 1
27 100-8335 GROUND WIRE ASSY, 14GA, 36”LG,GREEN, 1
28 780-4300 FOOT PEDAL ASSY WITH VALVE, LIGHT DUTY 1
29 UDP2TAB 2”DIA-PUMP 1
30 150-3780 LIQUID FLOW CONTROL ASSEMBLY 1
31 150-8115SKS SOLVENT WASH PAIL, HDPE 1

19
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03

20
MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023-03
Full Product Warranty
These Uni-ram products have been engineered and manufactured to high performance standards.
Each unit has been subjected to detailed factory testing before shipment.
This product comes with a one-year full warranty from the date of purchase. Uni-ram Corporation
reserves the right to repair or replace the unit, free of charge, to the original purchaser if a part is found
to be defective in material or workmanship as determined by factory service personnel. The items
listed below under "Conditions of Warranty" as consumables are not covered.
Uni-ram reserves the right to direct the customer to ship the unit collect to the Uni-ram factory or to an
approved Service Center for repair using the Uni-ram Return Goods Procedure or to repair the unit on-
site. To prevent damage in transport, the purchaser must ship the unit in the original packaging or use
alternate adequate packaging. All units must be shipped clean and free of liquid.
Diaphragm Pump:
We are pleased to advise that the warranty on the diaphragm pump, the heart of the spray gun
cleaner, comes with a 2 year replacement warranty. If, in the unlikely event your diaphragm pump fails
during the first two years of service, call Uni-ram Service at 1-800-417-9133. We will send you a new
pump free of charge and arrange for the return of your original pump.
Conditions of Warranty:
As Uni-ram Corporation has no control over the working conditions or circumstances under which the
purchaser stores, handles or uses the product, Uni-ram makes no warranty or claim, either expressed
or implied with respect to this product's fitness for any purpose or the result to be obtained from its
use. This condition applies to the sale of all products and no representative or distributor of Uni-ram
Corporation has the authority to waive or change these conditions.
This warranty applies only to the original purchaser and does not apply if the unit has been misused,
overloaded, neglected, altered or used for any purpose other than those specified in the operating and
installation instructions. Deterioration due to normal wear is not covered by this warranty. Damage due
to accident, transportation, fire, floods or acts of God is also not covered. Units whose serial numbers
have been altered or removed are not covered. The warranty is invalid if unauthorized chemicals as
noted in the manual or liquids with acid content are used in this unit. Unauthorized attempts at self-
repair or alterations by the owner also invalidate this warranty. Interior or exterior finishes are not cov-
ered by this warranty.
Consumable Items are not covered by this warranty (eg: gaskets, screens, bags, filters, nozzles and
air jets).
This warranty replaces all other warranties expressed or implied by statute or otherwise.
To make a claim, call Uni-ram Service at 1-800-417-9133 and quote the serial number of the unit.
This manual suits for next models
1
Table of contents
Other Uni-ram Ultrasonic Jewelry Cleaner manuals

Uni-ram
Uni-ram UG7500 Series User manual

Uni-ram
Uni-ram UG4000D User manual

Uni-ram
Uni-ram UG110 User manual

Uni-ram
Uni-ram UG2000DM Series User manual

Uni-ram
Uni-ram UG4000D Manual

Uni-ram
Uni-ram UM80W User manual

Uni-ram
Uni-ram UG7500W User manual

Uni-ram
Uni-ram UG5000W User manual

Uni-ram
Uni-ram UG5000W Manual
Popular Ultrasonic Jewelry Cleaner manuals by other brands

Cleanfix
Cleanfix SC1250 Foam Operating instruction

Qleen
Qleen Rotaqleen Vario user manual

Swann
Swann DIRT MASTER CROSS OVER user manual

Steren
Steren LIM-RAY instruction manual

Audiodesksysteme Glass
Audiodesksysteme Glass Vinyl Cleaner PRO operating instructions

Tower Hobbies
Tower Hobbies T131000BLG quick start guide