Unipulse F377A User manual

18JUL2012REV.3.06
DIGITAL INDICATOR
F377A
OPERATION MANUAL

Introduction
1
Introduction
Thank you very much for purchasing our Digital Indicator F377A.
For good performance, and proper and safe use of the F377A, be sure to read this operation manual and
properly understand the contents of it before use. Also, carefully keep this operation manual so that it can
be referred to at any time.
Cautions and Requests for Use
●Do not disassemble the main body for modifications or repair.
●Be sure to use crimp contacts for connection to terminal blocks, and do not to connect bare wires as
they are.
●Be sure to ground the protective ground terminal.
- The main F.G. is indicated by , it must be grounded with the protected earth.
●Be sure to disconnect the power cable when performing the following.
- Attachment / detachment of connectors of options.
- Wiring / connection of cables to terminal blocks.
- Connection of the ground line.
●For sensor(s), external input / output, and option, use shielded cables.
●Carefully check wiring, etc. before applying power.
●Take an interval of more than 5 seconds when repeating ON/OFF.
●Use F377A with correct supply voltage.
●Take adequate shielding measures when using at the following locations.
- Near a power line.
- Where a strong electric field or magnetic field is formed.
- Where static electricity, relay noise or the like is generated.
●Do not install in the following environments.
- The places where is exposed to direct sunlight.
- The places where is the temperature and/or humidity exceeds the range in the specifications.
- The places where is containing corrosive gas or flammable gas.
- The places where is with large quantities of dust, salt or iron powder.
- The places where is the product may be splashed with water, oil or chemicals.
- The places where is the main body is directly affected by vibration or shock.

Safety Precautions
2
Safety Precautions
●Indications for safe use and their meanings
In this manual, precautions for using the F377A Digital Indicator safely are indicated as follows. Be sure to
follow the precautions given here because they are important descriptions relating to safety.
Indications and their meanings are as follows:
●Explanation of pictographs
The △means a caution (or warning).
A specific description is written in the △.
The illustration on the left-hand side shows "Caution: May explode".
The △means a caution (or warning).
A specific description is written in the △.
The illustration on the left-hand side shows a general caution.
●About the built-in lithium battery
WARNING
Misuse may cause the risk of death or serious
injury to persons.
Misuse may cause the risk of injury to persons or
damage to property.
CAUTION
Never disassemble, deform under pressure or throw the battery
into fire. The battery may explode, catch fire or leak.
- Battery
Model: CR2477-1HF made by Matsushita Battery Industrial Co., Ltd.
Nominal voltage: 3V
Nominal electric capacity: 1000mAh
Battery life: approx 5-7 years
WARNING Misuse may cause the risk of death or
serious injury to persons.

RoHS-Compliant Product
3
●About the signal I/O terminal block
RoHS-Compliant Product
The parts and attachments (including the operation manual, packaging box, etc.) used for this unit are
compliant with the RoHS Directive restricting the use of hazardous substances with regard to adverse
effects on the environment and human body.
What is RoHS?
It is an abbreviation for Restriction on Hazardous Substances, which is implemented by the
European Union (EU). The Directive restricts the use of six specific substances in electric and
electronic equipment handled within EU borders. The six substances are lead, mercury, cadmium,
hexavalent chromium, PBB (polybrominated biphenyls), and PBDE (polybrominated diphenyl
ethers).
For connection to the signal I/O terminal block, wire correctly after checking the
signal names and terminal block numbers.
Also, turn off the power of the main body before connection / wiring to the signal
I/O terminal block.
CAUTION Misuse may cause the risk of injury to
persons or damage to property.

What is RoHS?
4
M E M O

CONTENTS
5
This operation manual consists of a standard volume and expansion volume.
CONTENTS
1 OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1-1. Contents of the Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1-2. About Connectable Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1-3. Appearance Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
■Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
■Rear panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2 INSTALLATION & CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2-1. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2-2. Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
■Power input connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
■Analog input / output terminals connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
■Voltage・Current Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
■SI/F connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
■External I/O connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
■RS-232C interface connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
■Voltage output connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
■Connecting to cage clamp terminal block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3 SETTING PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3-1. Screens And Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
■Setting modes tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
■F377A screen configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
■About a setting call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4 CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4-1. Calibration Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4-2. Calibration Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4-3. Calibration Value Selection
(This step may be omitted if there is no change.)31
■Calibration value selection by touch panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
■Calibration value selection by external signal input . . . . . . . . . . . . . . . . . . . . . 32
4-4. Analog Input Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
4-5. Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
4-6. Zero Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
4-7. Equivalent Input Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

CONTENTS
6
■Registration method at decimal place . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
4-8. Actual Load Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4-9. Increment (This step may be omitted if there is no change.). . . . . . . . . . . . . . . . . . . 35
4-10.Digital Offset(This step may be omitted if there is no change.) . . . . . . . . . . . . . . . . . 36
4-11.Digital Zero Limit(This step may be omitted if there is no change.) . . . . . . . . . . . . . . 36
5 SETTING OF FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5-1. Digital Zero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
5-2. Digital Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
5-3. Analog Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
5-4. Motion Detect (MD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
5-5. Zero Tracking (ZT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
5-6. Backlight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
5-7. Display Language Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
5-8. SI/F Print Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
5-9. Indicate Color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5-10.Comparison Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
■HI limit / LO limit / HH limit / LL limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
■Hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
■Near zero. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
■Comparison timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
■Comparison output selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
■Alarm HI and LO limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
5-11.Hold Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
■Hold setting --- Common --- . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
■Hold setting --- Relative (Maximum / Minimum / Difference) --- . . . . . . . . . . . 47
■Hold setting --- Inflection point --- . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
■Hold setting --- Average value --- . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
■Hold operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
■How to specify the hold detection section(Peak, Valley, P-P, Average) . . . . . . 54
5-12.Multi-hold Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
■About changing of the setting work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
■Work copy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
5-13.Measurement Work Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
5-14.Control Input Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
5-15.B6 OFF Detection Wait. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
5-16.B8 OFF Detection Wait. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
5-17.Waveform Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
■Graphic display screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
■Cursor display screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
■Graph plotting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
■Graph mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

CONTENTS
7
■Interval time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
■Graph start level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
■Level detection conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
■X(Time) end point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
■Y(Load) start point and Y(Load) end point . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
5-18.Voltage Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
5-19.Screen Lock / Key Lock (B5 terminal function selection) . . . . . . . . . . . . . . . . . . . . . . 64
5-20.Event Output at the End of Graph Plotting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
5-21.RUN Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
5-22.RS-232C Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
■Communication specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
■RS-232C interface setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
■Communication mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
■Communication format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
6 OPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
6-1. BCD Data Output (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
■Connector pin assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
■BCD output select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
■BCD output rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
■Logic switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
■BCD data hold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
■Equivalent circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
■Signal timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
■Self check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
6-2. D/A Converter (Option). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
■Scale setting value selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
■Zero scale output value and full scale output value . . . . . . . . . . . . . . . . . . . . . 76
■D/A output select. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
6-3. External I/O (Source type (ISC) option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
7 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
7-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
■Analog section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
■Digital section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
■Standard interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
■Options interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
■External input and output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
■General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
■Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
7-2. Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
■Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
■Equipped with BCD parallel data output interface option . . . . . . . . . . . . . . . . . 82
■Equipped with CC-Link interface option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
■Equipped with Device Net interface option . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
7-3. F377A Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

CONTENTS
8
8 SUPPLEMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
8-1. Error Display List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
■Sensor +error or Sensor -error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
■+Over or -Over (Overflow error) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
■Overload (Overload error) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
■Zero error (Zero calibration error) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
■Span error (Span calibration error) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
■Zero limit (Digital zero limit error) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
8-2. Protect / Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
■Work setting protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
■System setting protect. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
■Calibration protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
■Expansion protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
■Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
8-3. Self-Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87
■Self-check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
■Password. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
8-4. Unit Setting List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
8-5. Setting Item List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
■Work setting Comparison setting (WORK0 to WORK15). . . . . . . . . . . . . . . . 89
■Work setting Hold setting (WORK0 to WORK15). . . . . . . . . . . . . . . . . . . . . . 89
■Work setting Graph setting (WORK0 to WORK15) . . . . . . . . . . . . . . . . . . . . 90
■Calibration (CAL0 to CAL3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
■System setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
■Protect / Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
■Self check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

CONTENTS
9
CONTENTS
<Expansion>
1 EXP. HOLD FUNCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
1-1. Double Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
■Screens appearing when double hold is selected. . . . . . . . . . . . . . . . . . . . . . . 97
■Double hold setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
■Hold operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
■HI/LO limit comparisons of double hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
1-2. Sample Hold Trigger Edge Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
■Sample trigger selection setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
■Sample trigger select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
1-3. Auto Reset Selection at the Start of Hold Detection. . . . . . . . . . . . . . . . . . . . . . . . . 112
■Auto reset select setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
■Hold auto reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
1-4. Hold Off on Digital Zero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
1-5. Renewal of Hold Value. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
1-6. Hold End Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
■Hold operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
2 EXP. COMPARISON FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
2-1. Before Value Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
■Before value comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
■Screens appearing when before value comparison is selected . . . . . . . . . . . 117
■Before value renewal condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
■Difference HI/LO limit comparisons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
■Before value regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
2-2. Before Value Comparison in Double Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
■Comparison standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
■Double hold and difference-HI/LO limit comparisons . . . . . . . . . . . . . . . . . . . 119
2-3. Relative Value Comparison (in expansion double hold only) . . . . . . . . . . . . . . . . . . 120
■Screens appearing when relative value comparison is selected. . . . . . . . . . . 121
■Relative-HI/LO limit comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
■Comparison standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
■Relative value HI/LO limit comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
2-4. Before Value Comparison and Relative Value Comparison
(in expansion Double Hold only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
■Screens appearing when before value comparison &
relative value comparison are selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
■Difference Value- and relative-HI/LO limit comparisons . . . . . . . . . . . . . . . . . 124
3 EXP. GRAPH FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
3-1. Graph Pre Trigger Display Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
■Pre trigger display setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
■Pre trigger value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
4 EXP. OPERATION FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127

CONTENTS
10
4-1. CR Characteristic (Primary) Digital Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
■Digital filter character. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
4-2. Averaging on Digital Zero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
■Average time on digital zero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
4-3. RUN Output Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
■RUN output selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
5 EXP. OPTION FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
5-1. BCD Output Data Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
6 STANDARD INTERFACES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
6-1. SI/F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
6-2. RS-232C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
7 OPTION INTERFACES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
7-1. BCO Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
■BCD output data list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
7-2. DAV/DAI Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
7-3. CC-Link Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
7-4. DeviceNet Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
8 SUPPLEMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
8-1. Setting Item List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
■Work setting Comparison setting (WORK0 to WORK15). . . . . . . . . . . . . . . 139
■Work setting Hold setting (WORK0 to WORK15). . . . . . . . . . . . . . . . . . . . . 141
■Work setting Graph setting (WORK0 to WORK15) . . . . . . . . . . . . . . . . . . . 145
■RS-232C special setting Work setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
■RS-232C special setting Calibration setting . . . . . . . . . . . . . . . . . . . . . . . . . 145
■Calibration (CAL0 to CAL3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
■System setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
■Expansion setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149

11
11
STANDARD

12
12
M E M O

1 OUTLINE
13
OUTLINE
Chapter
1
1-1. Contents of the Package
The packaging box contains the following.
Be sure to check them before use.
1-2. About Connectable Devices
1OUTLINE
05JAN2005REV.1.00
DYNAMICFORCEPRO CESSOR
F377
DIGITAL
INDICATOR
DIGITAL
INDICATOR
INDICATOR
DIGITAL
INDICATOR
DIGITAL
INDICATOR
DIGITAL
INDICATOR
DIGITAL
INDICATOR
INDICATOR
DIGITAL
INDICATOR
DIGITAL
INDICATOR
DIGITAL
INDICATOR
DIGITAL
INDICATOR
[
]
F377A body・・・1 F377A operation manual・・・1
External input / output connector・・・1set
Connector : FCN-361J024-AU
Cover : FCN-360C024-B
Jumper wire・・・1
(for connectingcurrent output device)
Printer Display Various converters
(Option)(Option)
(Option)
(Option)
PC
PLC
D/A Converter
Valve, recorder

1 OUTLINE
14
OUTLINE
Chapter
1
1-3. Appearance Description
■Front panel
Touch panel display
This is the touch panel display for displaying an indicated value and graph set value and for setting
various setting items of the F377A. During measurement, a comparison display, hold display and
graph display can be selected according to the function in use.
Status indicator lamp
Comparison
Indicated value
Setting input
Hold status display
Setting mode
Digital zero
Touch panel
Status indicator
Display change
button
display
button
status display
display
screen call
button
button
lamp
Comparison display Hold display Graph display
Lamp indication Status
Green lighting Steady state
Orange lighting Writing into internal NOVRAM. Do not turn off the power of
the F377A.
Yellow blink
The voltage of the lithium battery for internal memory backup
has dropped. The battery needs to be replaced. Ask us for
replacement of the battery.

1 OUTLINE
15
OUTLINE
Chapter
1
■Rear panel
Analog input / output connector
Adaptable plug (ETB42-07P) (manufactured by OSADA or equivalent)
(Connector optional type: CN80)
Signal input / output connector
Adaptable plug (FCN-361J024-AU) (manufactured by FUJITSU COMPONENT or equivalent)
Connector cover (FCN-360C024-B (manufactured by FUJITSU COMPONENT or equivalent)
(Connector & Cover optional type: CN50)
Signal input / output
Protective ground
Option board
DC power input
RS-232C connector
Analog input / output
connector
connector
terminal block
mounting slot
Frame ground
7-MONITOR
6+MONITOR
5SHIELD
4A.GND
3in -
2Iin +
1Vin +
A1 *COM1 B1 *COM2
A2 出HH B2 入WORK0
A3 出HI B3 入WORK1
A4 出OK B4 入WORK2
A5 出LO B5 入WORK3(LOCK)
A6 出LL B6 入T/H
A7 *COM1 B7 *COM2
A8 出HOLD END(H/E) B8 入SECTION
A9 出RUN B9 入D/Z
A10 出EVENT B10 入GRAPH TRIG
A11 出SI/F B11 入CAL0
A12 出SI/F B12 入CAL1

1 OUTLINE
16
OUTLINE
Chapter
1
See the section on "Voltage・Current Connection" page 20 for connection.
See the section on "Voltage output connection" page 23 for connection.
See the section on "External I/O connection" page 21 for connection.
See the section on "External I/O connection" page 21 for connection.
See the section on "SI/F connection" page 21 for connection.
Vin +
Iin +
in -
A.GND
SHIELD
The terminal for connecting a device of voltage or current output
(sensor)
+MONITOR
-MONITOR
The voltage output terminal for sensor input monitor.
→page64 "Voltage Output"
COM1 The terminal common to output signals.
OK
HI
LO
HH
LL
RUN
Outputs the OK signal.
Outputs the HI signal.
Outputs the LO signal.
Outputs the HH signal.
Outputs the LL signal.
Outputs the RUN signal.
HOLD END
(H/E)
Outputs the hold end signal.
→page45 "Hold Functions"
EVENT Outputs the event signal when graph plotting ends.
COM2 The terminal common to input signals.
WORK0
WORK1
WORK2
WORK3(LOCK)
Selects the work No. for the multi-hold function.
→page56 "Multi-hold Function"
WORK3 is also usable as a LOCK terminal.
→
page64 "Screen Lock / Key Lock (B5 terminal function selection)"
T/H
SECTION
D/Z The input for digital zero (making the indicated value zero).
→ page37 "Digital Zero"
GRAPH
TRIG
The input for controlling the drawing of graphic display.
→page60 "Graph plotting"
CAL0
CAL1
Selects the CAL No. for calibration value selection function.
→ page32 "Calibration value selection by external signal input"
SI/F The 2-wire serial interface for coupling a UNIPULSE printer,
external display, etc.
→ page41 "Comparison
Functions"
→ page65 "RUN Output"
The input for controlling the hold signal.
→ page45 "Hold Functions"

1 OUTLINE
17
OUTLINE
Chapter
1
DC power input terminal block
Connect the DC power cord. The power supply voltage is 24V DC (±15%).
Adaptable crimp terminal [TMEV1.25-3S]
Frame ground (functional ground)
F.G. terminal. (There is continuity between the casing and F.G. terminal.)
Protective ground
Protective ground terminal. Be sure to ground the protective ground terminal to prevent electric
shocks and injury by static electricity. (There is continuity between the casing and protective
ground terminal.)
Optional slot
Any one of the following optional boards can be mounted.
- BCD data output
- D/A converter (voltage or current output)
- CC-Link interface
(CC-Link is an abbreviation for "Control & Communication Link".)
- DeviceNet interface
RS-232C connector
RS-232C connector to transmit / receive measurement data and status information, etc.
The adaptable plug is HOSIDEN-manufactured TCP8080-015267 or equivalent.
Optionally available RS-232C cable (cross) [CA81-232X] is connectable.

2 INSTALLATION & CONNECTION
18
INSTALLATION & CONNECTION
Chapter
22-1. Installation
To install the F377A into a control panel, use the following procedure.
1. Make a hole in the panel according
to the panel-cut dimensions.
2. Remove the screws (two), and
remove the guide rails from both
sides.
* Do not use other screws than
those installed to the F377A body.
3. Fit in the F377A from the front of
the panel.
4. Install from the rear the guide rails
having been removed from both
sides in Step 2, and fix them with
the screws (two).
2-2. Connection
■Power input connection
Connect the positive (+) side of the power source to
the red screw side of the terminal block on the back
of the F377A, and its negative (-) side to the black
screw side. The input voltage is 24V DC(±15%).
2INSTALLATION & CONNECTION
92mm
Panel-cut
+1
0
–
Panel thickness
1.6 to 3.2mm
dimensions
92mm
+1
0
–
Black
Red screw
screw Within 6mm
CAUTION
Be aware that the voltage drops
depending on the wire thickness and
length. Also, never input an AC power
source. Doing so will cause a failure.

2 INSTALLATION & CONNECTION
19
INSTALLATION & CONNECTION
Chapter
2
■Analog input / output terminals connection
How to connect
1. Strip 5mm of the covering of the wire to be
connected.The size of connectable wires is
from 0.21 to 3.31mm2(AWG12 to 24).
2. Twist the tip to such an extent that it will not spread out.
3. Loosen the screw with a screwdriver to open
the connection hole.
A Phillips screwdriver 3 to 3.5mm #1 in shaft
diameter is recommended.
(Precision screwdriver, etc.)
4. Insert the wire into the connection hole so as
not to let the tip spread out.
5. Tighten the screw with the screwdriver.
0.5Nm of tightening torque is recommended.
6. Lightly pull the wire to make sure that it is securely clamped.
7. Insert the wire-connected plug into the
F377A body, and tighten the screws (two).
How to remove the terminal block
1. Loosen the screws (two) with a screwdriver.
2. Remove the terminal block by giving it a
strong pull.
5mm
Adaptable plug ETB42-07P (attachment)
Tighten.
(Turn clockwise.)
Pin No. 7
Pin No. 1
(Turn counterclockwise.)
Loosen.
We sell it as CN80 (optional).
Pin No. 7
Pin No. 1
Tighten.
(Turn clockwise.)
Tighten.
(Turn clockwise.)
Loosen.
(Turn
counterclockwise.
.)
Loosen.
(Turn
counterclockwise.
.)
When installing the terminal block to the F377A body,
check its orientation. (See the illustration at the right.)
Attention
Insert side
Right side
Table of contents
Other Unipulse Measuring Instrument manuals

Unipulse
Unipulse F325 User manual

Unipulse
Unipulse UTM II-20Nm User manual

Unipulse
Unipulse USH-10KN User manual

Unipulse
Unipulse UPM100 User manual

Unipulse
Unipulse F701+ User manual

Unipulse
Unipulse TM500 User manual

Unipulse
Unipulse TM400 User manual

Unipulse
Unipulse F340A User manual

Unipulse
Unipulse F372A User manual

Unipulse
Unipulse TM201 User manual