Page 16 107098-002 TM12 - Operator Manual
Specifications
S
PECIFICATIONS
Specifications subject to change without notice. Refer to the Service Manual for service and repair infor-
mation. Refer to the Parts Manual for illustrated parts breakdown. Hot weather or heavy use may reduce
performance. Meets or exceeds all applicable national safety requirements
*Specifications are subject to change without notice. Hot weather or heavy use may affect performance.
Refer to the Parts Manual and the Service Manual for complete parts and service information.
The TM12 meets or exceeds all applicable requirements of OSHA and ANSI A92.6-1999.
ITEM TM12
Platform Size 73,7 cm x 1,04 m (29 in. x 41 in.)
Maximum Platform Capacity 227 kg (500 lbs.)
Maximum Number of Occupants 2 People
Height
Working Height 5,83 m (19 ft.)
Maximum Platform Height 3,66 m (12 ft.)
Minimum Platform Height 48,3 cm (19 in.)
Dimensions
Weight 776 kg (1710 lbs.)
Overall Width 76 cm (30 in.)
Overall Height (Lowered) 165 cm (65 in.)
Overall Length 1,36 m (53.5 in.)
Drive Speed
Platform Lowered 3,65 km/h (2.27 mph)
Platform Raised 0,87 km/h (0.54 mph)
Energy Source 24V battery pack
Four 220 ampere hour, 6 Volt batteries, min. wt. 26,3 kg (58 lbs.) each
4 HP DC electric motor
System Voltage 24 VDC
Battery Charger 20 AMP, 220 VAC 50Hz
Battery Duty Cycle 25% for 8 Hours
Hydraulic Reservoir Capacity 7,2 L (1.9 gal)
Maximum Hydraulic System Pressure 165 bar (2400 psi)
Hydraulic Fluid
Normal above 0° C [32° F] ISO #46
Low Temp. below 0° C [32° F] ISO #32
below -17° C [0° F] ISO #15
Lift System One Single Stage Lift Cylinder
Drive Control Proportional
Control System Proportional Control Handle with Interlock, Selector Switch,
Red Mushroom Emergency Stop Switches
Horizontal Drive Dual Front Wheel
Tires 30,5 cm (12 in.) diameter solid rubber, Non-marking
Parking Brakes Dual, Spring Applied, Hydraulic Release
Turning Radius (Inside) 37 cm (14.5 in.)
Maximum Gradeability 14º (25%)
Wheel Base 97,8 cm (38.5 in.)
Guardrails 1,10 m (43 in.)
Toeboard 152 mm (6 in.)
107098-002 TM12 - Operator Manual Page 1
OPERATOR MANUAL
WARNING
All personnel shall carefully read, understand and follow all safety rules, operating instructions,
and the Scaffold Industry Association’s MANUAL OF RESPONSIBILITIES of ANSI A92.6-1999
before performing maintenance on or operating any UpRight Aerial Work Platform.
Safety Rules
Safety RulesSafety Rules
Safety Rules
•NEVER operate the machine without first surveying the work area for surface hazards such as holes, drop-offs, bumps,
curbs, or debris.
•NEVER operate the machine if all guardrails are not properly in place and secured with all fasteners properly torqued.
•ALWAYS close and secure the entrance after entering the platform.
•NEVER use ladders or scaffolding on the platform.
•NEVER exceed the maximum platform load. See “Specifications” on page 16.
•NEVER attach overhanging loads or increase platform size.
•LOOK up, down and around for overhead obstructions and electrical conductors.
•DISTRIBUTE all platform loads evenly on the platform.
•NEVER use damaged equipment. (Contact UpRight for instructions. See toll free phone number on inside back cover.)
•NEVER change operating or safety systems.
•INSPECT the machine thoroughly for cracked welds, loose or missing hardware, hydraulic leaks, damaged cables or
hoses, loose wire connections, and wheel bolts.
•NEVER climb down elevating assembly when the platform is elevated.
•IF ALARM SOUNDS while the platform is elevated, STOP, carefully lower the platform. Move the machine to a firm, level
surface.
•IN CASE OF EMERGENCY push the Emergency Stop Switch to cut power to all machine functions.
•NEVER perform service on the machine while the platform is elevated without blocking the elevating assembly.
•NEVER recharge batteries near sparks or open flame; batteries that are being charged emit explosive hydrogen gas.
•NEVER replace any component or part with anything other than original UpRight replacement parts without the manufac-
turer’s written consent.
•VERIFY that all labels are in place and legible before using.
•NEVER tow the machine. Transport by truck or trailer only.
•AFTER USE, secure the machine against unauthorized use by turning the Chassis Key Switch off and removing the key.
California Proposition 65 Warning
Battery Posts, terminals and related accessories contain lead compounds, chemicals known to the State of
California to cause cancer and reproductive harm. Wash hands after handling.
NEVER operate or drive with the
platform elevated unless on firm, level
surface.
NEVER position the machine without
first checking for overhead obstructions
or other hazards.
NEVER climb, stand or sit on the
platform guardrails or midrail.
Electrocution Hazard
Electrocution HazardElectrocution Hazard
Electrocution Hazard Tip Over Hazard
Tip Over HazardTip Over Hazard
Tip Over Hazard Collision Hazard
Collision HazardCollision Hazard
Collision Hazard Fall Hazard
Fall HazardFall Hazard
Fall Hazard
NEVER operate the machine within ten
(10) feet of power lines.
THIS MACHINE IS NOT INSULATED.