V-ZUG GK17TIYSZ User manual

Installation instructions
Built-in variants
Teppan Yaki
GK17TIYSZ, GK27TIYSZ
1014839-R03
21/11/2017
1014839-R03
1
The appliance must be installed by qualified personnel only. Each step must be carried out and checked in full in the
order specified.
Validity
These installation instructions apply to the following models:
Product family Type
31076 GK17TIYSZ
31077 GK27TIYSZ
General notes
If installing into a combustible material, the guidelines and standards for low voltage installations and fire protection
must be strictly observed.
Identification plate
The identification plate is located on the underside of the
appliance.
Identification plate
Connection plate
▸Affix the second identification plate (supplied) in an accessible position behind the front of the fitted cabinet beneath the appliance.
Care and maintenance
▸Follow the care and cleaning advice in the operating instructions.
▸Follow the basic maintenance advice in the operating instructions.

Installation instructions
Built-in variants
Teppan Yaki
GK17TIYSZ, GK27TIYSZ
1014839-R03
21/11/2017
1014839-R03
2
Features
Designation Art. no.
Cementing-in instructions J004133
Sealing strip set H62695
Spacer set H60330
Installation accessories
Surface-mounted installation:
Designation Art. no.
Stainless steel intermediate support for the surface-mounted combination of several hobs 1014361
Black intermediate support for the surface-mounted combination of several hobs 1019199
Side strip set for surface-mounted combination with intermediate support 1028587
Flush installation:
Designation Art. no.
Steel angle set, hob size 40
Steel angle set, hob size 60
H63771
H63772
Ventilation protective plate set for niche width 550 mm
Ventilation protective plate set for niche width 600 mm
H61082
H61083
Intermediate support kit for the flush-mounted combination of several hobs (contains two intermediate supports) H63789
Instant adhesive for installation of steel angle
Permabond F246 (incl. activator), 50 ml tube. From Silitech AG, 3008 Berne.
B11502
Cement set
Complete with cleaning agent, primer type 1105, cartridge with black silicone adhesive, with nozzle. Suitable for all
absorbent worktop materials (wood and natural stones such as marble or granite).
86.3928.85
Special primer type 107
Suitable for non-absorbent worktop materials (not suitable for polyethylene, polypropylene or Teflon).
45.2771.76

Installation instructions
Built-in variants
Teppan Yaki
GK17TIYSZ, GK27TIYSZ
1014839-R03
21/11/2017
1014839-R03
3
Electrical connection
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.
▸The appliance is designed for use up to a max. altitude of 2000 m above sea level.
▸Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
The appliance is equipped with a connection cable which must be connected to an on-site junction box.
Installation pipe Distribution boxClamp
brown + black
blue
yellow/green
black
blue
yellow/green
brown
GK27TIYSZ - EU
black
black
yellow/green
GK17TIYSZ - EU + CN
N
L1
PE/
220–240 V~
1 1 1 1 1 1 1 1
2 2 2 2 2 2 2 2
brown
blue
yellow/green
N
L1
PE/
220–240 V~
GK27TIYSZ - CN
L2
L1
N
N
L1
PE/
PE/
380–415 V 2N~
220–240 V~
Error message U400
Faulty connection:
A pole conductor has been connected to the connection terminal for neutral conductors.
Quickly disconnect the appliance from the mains!
Ventilation
In order to guarantee good ventilation, a space of ≥10mm
height is necessary beneath the appliance.
1. The rear panel of the base unit must be open around the
work surface cut-out to guarantee continuous air circula-
tion via the ventilation slits.
The air must be drawn in from outside the cabinet and be
able to circulate freely from inside the cabinet to the hob.
2. Alternatively, a concealed fresh air supply can ensure air
circulation inside the cabinet.
In order that enough cold air can be drawn in, there must
be a continuous circulation of fresh air that extends outside
the cabinet.
The air must be drawn in from outside the cabinet and be
able to circulate freely from inside the cabinet to the hob.
≥15
21

Installation instructions
Built-in variants
Teppan Yaki
GK17TIYSZ, GK27TIYSZ
1014839-R03
21/11/2017
1014839-R03
4
Surface-mounted installation
The cooking zone layout of the hob to be fitted may differ from the hob illustrated!
600
≥300
600/500
490 1
≥50 ≥50
A
On both sides
for technical reasons
560 1
Ra
≥50
600
600/550
490 1 ≥50
≥300
≥400
373 1
384
501
Ra
Ri
GK17TIYSZ
Y
Y
H
On both sides
for technical reasons
Ri
501
571
GK27TIYSZ
Y
Y
H
H
≥10 *
Y – Y
B
Drawer/Cabinet
Side panel
* The required clearance must be observed!
Type A Depends on producer B H Corner radius Ra/Ri
GK17TIYSZ, GK27TIYSZ ≥30mm ≥77.6mm 64mm 0–5/1.5mm
AWorktop depth (in combination with directly built-under oven; does not apply to small appliances)
BRequired clearance for service replacement
HDimension from the top of the work surface to the underside of the hob (ventilation opening)
Ri Corner radii of appliance Ra Outer corner radii of cut-out
Installation
Do not damage the sealing bead.
The sealing bead must lie all around the edge of worktop.
▸Create an accurate installation cut-out.
▸Carefully put the appliance in the installation cut-out and press against the worktop with sufficient overlap.
Combination installation
For surface-mounted combination installation, the side strip set 1028587 and the intermediate support 1014361 (stainless steel) or
1019199 (black) is needed.
▸The side strips must be fixed on the left-hand and right-hand side of the appliance with four screws on each side.
Surface-mounted combination installation is described in document 1013773.

Installation instructions
Built-in variants
Teppan Yaki
GK17TIYSZ, GK27TIYSZ
1014839-R03
21/11/2017
1014839-R03
5
Flush installation
The cooking zone layout of the hob to be fitted may differ from the hob illustrated!
600
300
600/500
507±1
41.5 41. 5
A
On both sides
for technical reasons
577±1
Z
Steel angle bonded
or screw mounted
C
D
Ra
R0–5
8.5
8.5
8.5±0.5 8.5±0.5
0
-1
0
-0.5
Detail Z
Ri
501
571
GK27TIYSZ
Y
Y
H
X
X
41.5
600
600/550
507±1 41.5
300
400
390±1
Z
On both sides
for technical reasons
384
501
Ri
GK17TIYSZ
Y
Y
H
H
10 *
Y – Y
B
Drawer/Cabinet
Side panel
B
H
10 *
X – X
For 550 niche,
for GK27TIYSZ
* The required clearance must be observed!
Type A Depends on producer B H Corner radius Ra/Ri C/D
GK17TIYSZ ≥30mm ≥73.6mm 64mm 5/1.5mm 373/490mm
GK27TIYSZ 560/490mm
AWorktop depth (in combination with directly built-under oven; does not apply to small appliances)
BRequired clearance for service replacement
HDimension from the top of the work surface to the underside of the hob (ventilation opening)
Ri Corner radii of appliance Ra Outer corner radii of cut-out
Installation
▸Create an accurate installation cut-out.
–The mounting surface can be reamed out or created by installing wood/stone supports or using the steel angle set (see Ac-
cessories).
Access to the appliance from below via the entire cut-out area must be guaranteed. For servicing purposes, the appliance
base can be removed from below.
▸Prepare the cut-out and appliance according to the specifications in the enclosed cementing-in instructions and align the appliance
in the cut-out.
▸Carefully cement the appliance in and leave the silicone sealant to dry for at least 24 hours.
▸Connect to the electrical mains connection before inserting the appliance, if necessary.

Installation instructions
Built-in variants
Teppan Yaki
GK17TIYSZ, GK27TIYSZ
1014839-R03
21/11/2017
1014839-R03
6
Combination installation
Flush combination installation is described in document 1014381. The intermediate support kit H63789 is required for this.
Installation of the ventilation protective plate with 3 mm ventilation gap at the front
A ventilation protective plate is necessary for the adequate ventilation of the hob.
The distance between the underside of the appliance and the protective plate must be ≥10mm.
393
(30)
67.5
5..10
53.5
56
ø4
15
(X) H
3
≤0.5
2.5
Caution: Mains cable must
not touch protective plate!
Well-fitting seal over
width of cabinet element
Air gap over entire width of
cabinet element 17 cm²
According to template
Fan
Drawer
Type X Remarks
GK17TIYSZ, GK27TIYSZ 14.3mm Surface-mounted installation
10mm Flush installation
HDimension from the top of the work surface to the underside of the hob (ventilation opening).
Cool air supply with regard to drawer or cabinet installed below
In order to guarantee good ventilation, a space of ≥10mm height is necessary beneath the appliance.
Drawer Centre of fan
Air gap over the entire cabinet element width
≥5
≥15
(30)
600/550
GK17TIYSZ ≥400
≥25 cm²
H
B
A
ANecessary space below the worktop for the appliance.
BNecessary space below the worktop for the ventilation of the appliance.
HDimension from the top of the work surface to the underside of the hob (ventilation opening)

Installation instructions
Built-in variants
Teppan Yaki
GK17TIYSZ, GK27TIYSZ
1014839-R03
21/11/2017
1014839-R03
7
Changes to the service menu
Changes to the service menu can only be made within 1 minute of applying the voltage. If the appliance has already been connected
for a longer period, interrupt the power supply for about 10seconds.
▸With the hob switched off, hold the and buttons depressed at the same time for 4seconds.
–An acoustic signal is emitted.
▸Hold both sliders to the left of the button depressed at the same time for 4seconds.
–An acoustic signal is emitted.
▸Use the button to select the next highest and the button the next lowest user setting.
–The current service menu item is shown in the timer display.
The current value under the corresponding menu item is displayed above the first active slide to the left of the button. Use the first
active slider to the left of the button to change the values. The left half of the slider functions as the minus button and the right half
functions as the plus button.
Menu item Function Default setting Setting Description
Appliance configuration Default setting
Software version number
of touch control
The current software version
is displayed: U-x-x-x.
Software variant number
of touch control
The current software variant
is displayed: P-x-x-x.
Display text All displays illuminate.
Demo mode The demo mode is switched off.
The demo mode is switched on.
▸To save entries: Hold the and buttons depressed at the same time for 2 seconds.
–An acoustic signal is emitted.
–The «Service menu» mode is ended.
Cancelling user settings
▸Press the button.
–Any changes made to the default values are not saved.
–The «Service menu» mode is ended.
Other manuals for GK17TIYSZ
1
This manual suits for next models
3
Table of contents
Other V-ZUG Ventilation Hood manuals

V-ZUG
V-ZUG DWE9 User manual

V-ZUG
V-ZUG DF-SG5 User manual

V-ZUG
V-ZUG DWPQG Series User manual

V-ZUG
V-ZUG AiroClearCabinet V200 User manual

V-ZUG
V-ZUG DFPQ5 User manual

V-ZUG
V-ZUG DFL6 User manual

V-ZUG
V-ZUG DEHMR 5 User manual

V-ZUG
V-ZUG DW-N9 User manual

V-ZUG
V-ZUG AiroClearCabinet V4000 User manual

V-ZUG
V-ZUG DV 5 User manual