Range: Brix 0.0-20.0%
Resolution: 0.1%
Accuracy: ±0.1%
Dimensions: 40 x 40 x 185mm (1.6 x 1.6 x 7.3”)
Weight: 285g (10.0 oz.)
Supplied With: VinylCarryingCase(1),PlasticTransferPipet(1)
Printed in China VGMNL010320-43011
Operation Manual
Model BX-20
Brix 0-20%
Specifications
Cat. No. 43011
Temperature Correction Table
For Refractometers Calibrated At 20°C (l=589nm)
Source: ICUMSA, 1974
As an alternative to recalibration of the refractometer due to ambient temperature changes, the following temperature
correction table can be used. Ensuring that both the distilled water and the ambient temperature are both at exactly 20°C,
follow steps 2-7 under the CALIBRATION section on the preceding page. Once this is accomplished, if ambient temperature
changes, simply apply the temperature correction values listed below. For example, a reading of Brix 40.0% at 25°C is
corrected to Brix 40.4%; a reading of Brix 65.0% at 10°C is corrected to Brix 64.25%.
www. .com information@itm.com1.800.561.8187
Refractometer Components
Calibration Ring
Mechanismusedtozeroorcalibratetherefractometer,
withouttherequirementofadditionaltools.
Rubber Hood
Houses and protects the focusable lens. Prevents
lightfromenteringthroughtheeyepieceduringuse.
Rubber Grip
Insulatestherefractometeragainst hand
heatforaccurateresults.
Non-Roll Stand
Protectsagainstdamageto theinstrumentwhen
setdownbetweenmeasurements.
Daylight Plate & Prism
The prism and sample are covered by the
daylightplate during readings.
This refractometer is an optical instrument -- it can become damaged if dropped or handled in a rough manner.
Theprism is madeof optical glass and issusceptible to scratches-- donot apply anyrough or abrasivematerial andtake
care when cleaning the prism.
After each use, clean the prism surface and daylight plate with a soft cloth or tissue soaked in water and wipe off with
a dry cloth or tissue.
Do not hold the refractometer under a stream of water from a faucet. Do not splash it with or dip it in water.
If the surface of the prism becomes coated with an oily solution or similar, it will repel test samples and affect readings.
If this occurs, the prism should be cleaned with a weakened detergent or similar solvent.
2 3
1
2
55
55
5
44
44
4
33
33
3
Calibration
Precautions
Calibration should be conducted at the start of each day or when any shifts
in ambient temperature occur. If recalibration is impractical, refer to the
directions and temperature correction table on the following page.
For standard calibration procedures, please follow the directions below.
Openthe daylightplate andapply oneor twodrops ofdistilled water on to the
surfaceof the prism. Hold the prismat anangle close toparallel withthe floor
so the distilled water will not run off of the prism.
Gently close the daylight plate over the prism. The distilled water should
spread as a thin, even layer in between the daylight plate and the prism. By
looking through the daylight plate, ensure that the distilled water covers the
ENTIRE surface of the prism. If there are bubbles and gaps or if the distilled
wateris only onone portionof the prism, the distilledwater must bereapplied
(Figure1). Inaccuratecalibrations will result iftheprism is notcoveredcorrectly.
Looking through the eyepiece, hold the refractometer and direct the daylight
plate upwards towards light. If the scale is not in focus, adjust it by gently
turning the eyepiece (rubber hood) either clockwise or counterclockwise. Be
careful not to overturn the focusing mechanism.
When the refractometer scale is viewed through the eyepiece, the upper field
ofview will be seen as blue and thelower field will be seen as white (Figure2).
Confirm that the boundary line crosses the scale at “0” (Figure 3).
Ifthe boundaryline falls aboveorbelow zero, gentlyloosen the setscrewon the
calibrationring. Whilelooking through theeyepiece, gently turnthe calibration
ringclockwise or counterclockwiseuntil the boundaryline isat zero. Once this
is achieved gently tighten down the set screw. (NOTE: Do not over-tighten. If
the set screw is over-tightened, the boundary line may shift slightly).
When calibration is complete, gently wipe the prism using tissue paper.
Thank you for purchasing this VEE GEE Refractometer. With the user in mind, VEE GEE Refractometers are built from modern
designs and, with proper care, this instrument should provide many years of reliable performance. It’s recommended this
manual is read entirely before using the refratometer for the first time.
Introduction
Figure 1
Figure 2
Figure 3
Figure 4
Figure 3
1
2
55
55
5
44
44
4
33
33
3
General Use
Open the daylight plate and apply one or two drops of the sample solution to
the surface of the prism. Hold the prism at an angle close to parallel with the
floor so the sample will not run off of the prism.
Gently close the daylight plate over the prism. The sample solution should
spread as a thin, even layer in between the daylight plate and the prism. By
lookingthrough the daylightplate, ensurethat the samplesolution coversthe
ENTIRE surface of the prism. If there are bubbles and gaps or if the sample
is only on one portion of the prism, the sample solution must be reapplied
(Figure 1). Inaccurate readings will result if the prism is not covered correctly.
Looking through the eyepiece, hold the refractometer and direct the daylight
plate upwards towards light. If the scale is not in focus, adjust it by gently
turning the eyepiece (rubber hood) either clockwise or counterclockwise. Be
careful not to overturn the focusing mechanism.
When the refractometer scale is viewed through the eyepiece, the upper field
ofview will be seen as blue and thelower field will be seen as white (Figure4).
Thereading is takenat the point where theboundary line ofthe blueand white
fields crosses the scale (Figure 5). The value is the Brix% reading of the
sample.
When each measurement is complete, the sample must be cleaned from
the prism using tissue paper and water.
Calibration Ring Set Screw
Securesthecalibrationringin place to protect
fromanyshiftswhichcould occur during use.
Figure 5
Figure 3
66
66
6
77
77
7
www. .com information@itm.com1.800.561.8187

Other VEE GEE Measuring Instrument manuals

VEE GEE BX-20 User manual

VEE GEE

VEE GEE BX-20 User manual

VEE GEE BX-10 User manual

VEE GEE

VEE GEE BX-10 User manual

VEE GEE BX-2 User manual

VEE GEE

VEE GEE BX-2 User manual

VEE GEE STX-3 User manual

VEE GEE

VEE GEE STX-3 User manual

VEE GEE 43035 User manual

VEE GEE

VEE GEE 43035 User manual

VEE GEE BX-4 User manual

VEE GEE

VEE GEE BX-4 User manual

VEE GEE C10 User manual

VEE GEE

VEE GEE C10 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE CTX-1 User manual

VEE GEE

VEE GEE CTX-1 User manual

VEE GEE CTX-2 User manual

VEE GEE

VEE GEE CTX-2 User manual

VEE GEE BX-1 User manual

VEE GEE

VEE GEE BX-1 User manual

VEE GEE SX-2 User manual

VEE GEE

VEE GEE SX-2 User manual

VEE GEE 43045 User manual

VEE GEE

VEE GEE 43045 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE C25L User manual

VEE GEE

VEE GEE C25L User manual

VEE GEE BX-3 User manual

VEE GEE

VEE GEE BX-3 User manual

VEE GEE SGX-1 User manual

VEE GEE

VEE GEE SGX-1 User manual

VEE GEE BTX-20 User manual

VEE GEE

VEE GEE BTX-20 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE NDX-1 User manual

VEE GEE

VEE GEE NDX-1 User manual

VEE GEE BX-20 User manual

VEE GEE

VEE GEE BX-20 User manual

Popular Measuring Instrument manuals by other brands

Unico UV-2802 user guide

Unico

Unico UV-2802 user guide

Electro Industries/GaugeTech Shark 100T quick start guide

Electro Industries/GaugeTech

Electro Industries/GaugeTech Shark 100T quick start guide

Meterman AC50 user manual

Meterman

Meterman AC50 user manual

Lovibond Maxi Direct instruction manual

Lovibond

Lovibond Maxi Direct instruction manual

Bushnell TOUR V4 user manual

Bushnell

Bushnell TOUR V4 user manual

AFL NOYES OPM Series user guide

AFL

AFL NOYES OPM Series user guide

Ludlum Measurements 44-172 manual

Ludlum Measurements

Ludlum Measurements 44-172 manual

Ericsson DT-620 manual

Ericsson

Ericsson DT-620 manual

socomec COUNTIS E25 instruction manual

socomec

socomec COUNTIS E25 instruction manual

Keysight N432A Service guide

Keysight

Keysight N432A Service guide

ELGO Electronic Z58-SN004 manual

ELGO Electronic

ELGO Electronic Z58-SN004 manual

Fieldpiece HG3 Field manual

Fieldpiece

Fieldpiece HG3 Field manual

Sonic KDG-300 instruction manual

Sonic

Sonic KDG-300 instruction manual

MicroImage Video Systems VMU300 manual

MicroImage Video Systems

MicroImage Video Systems VMU300 manual

montwill M1 user manual

montwill

montwill M1 user manual

BD PhoenixSpec user guide

BD

BD PhoenixSpec user guide

IFM Electronic SD6100 operating instructions

IFM Electronic

IFM Electronic SD6100 operating instructions

Greyline Instruments SFM 6.1 Installation & operation instructions

Greyline Instruments

Greyline Instruments SFM 6.1 Installation & operation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.