Range:
Resolution:
Accuracy:
ATC Range:
Dimensions:
Weight:
Supplied With:
Brix 0.0-32.0% / Specific Gravity Beer Wort 1.000-1.130
Brix: 0.2% / Specific Gravity (Wort): 0.001
Brix: ±0.2% / Specific Gravity (Wort): ±0.001
10-30°C (50-86°F)
40 x 40 x 165mm (1.6 x 1.6 x 6.5”)
235g (8.3oz.)
VinylCarryingCase(1),PlasticTransferPipet(1),CalibrationScrewdriver(1)
Printed in China VGMNL030221-43004
Operation Manual
Model SGX-1
Specifications
Cat. No. 43004
Brix / SG Beer Wort
Automatic Temperature Compensation
Figure 4
Figure 3
1
2
55
55
5
44
44
4
33
33
3
General Use
Open the daylight plate and apply one or two drops of the sample solution to
the surface of the prism. Hold the prism at an angle close to parallel with the
floor so the sample will not run off of the prism.
Gently close the daylight plate over the prism. The sample solution should
spread as a thin, even layer in between the daylight plate and the prism. By
lookingthrough thedaylight plate,ensure thatthe samplesolution coversthe
ENTIRE surface of the prism. If there are bubbles and gaps or if the sample
is only on one portion of the prism, the sample solution must be reapplied
(Figure 1). Inaccuratereadings will result if the prism is not covered correctly.
Looking through the eyepiece, hold the refractometer and direct the daylight
plate upwards towards light. If the scale is not in focus, adjust it by gently
turning the eyepiece (rubber hood) either clockwise or counterclockwise. Be
careful not to overturn the focusing mechanism.
When the refractometer scale is viewed through the eyepiece, the upper field
ofview will be seen asblue and the lower fieldwill be seen aswhite (Figure 4).
Thereading is taken at thepoint where the boundaryline of the blueand white
fields crosses the scale (Figure 5). The value is the Brix/Specific Gravity
Beer Wort reading of the sample.
When each measurement is complete, the sample must be cleaned from
the prism using tissue paper and water. Figure 5
Warranty information and
registration form can be found at:
www.veegee.com/service_support
Refractometer Components
Rubber Hood
Houses and protects the focusable lens. Prevents
light from entering through the eyepiece during use.
Calibration Ring
Mechanismusedto zero or calibratetherefractometer.
Rubber Grip
Insulatestherefractometer against
hand heatforaccurate results.
Non-Roll Stand
Protectsagainstdamage to the instrument
when setdownbetween measurements.
Daylight Plate & Prism
Theprismand sample are coveredbythe
daylightplateduring readings.
This refractometer is an optical instrument -- it can become damaged if dropped or handled in a rough manner.
Theprism ismade ofoptical glassand issusceptible toscratches --do notapply anyrough orabrasive materialandtake
care when cleaning the prism.
After each use, clean the prism surface and daylight plate with a soft cloth or tissue soaked in water and wipe off with
a dry cloth or tissue.
Do not hold the refractometer under a stream of water from a faucet. Do not splash it with or dip it in water.
If the surface of the prism becomes coated with an oily solution or similar, it will repel test samples and affect readings.
If this occurs, the prism should be cleaned with a weakened detergent or similar solvent.
2 3
1
2
55
55
5
44
44
4
33
33
3
Calibration
Precautions
CalibrationofATC refractometersshouldonly beconductedwhen theprevious
calibration setting has shifted and is noticeably affecting measurements.
DO NOT PERFORM CALIBRATIONS IN THE FIELD! Calibration must
take place in a controlled environment of 20°C (68°F) using distilled water
of the same temperature. It’s recommended to allow the refractometer and
the distilled water to reach temperature equilibrium with the controlled
environment before calibration takes place.
Openthe daylight plateand apply oneor two dropsof distilled wateron to the
surfaceof theprism. Hold theprism atan angle closeto parallelwith thefloor
so the distilled water will not run off of the prism.
Gently close the daylight plate over the prism. The distilled water should
spread as a thin, even layer in between the daylight plate and the prism. By
looking through the daylight plate, ensure that the distilled water covers the
ENTIRE surface of the prism. If there are bubbles and gaps or if the distilled
wateris onlyon oneportion ofthe prism,the distilledwater must bereapplied
(Figure1). Inaccuratecalibrations willresultifthe prismisnot coveredcorrectly.
Looking through the eyepiece, hold the refractometer and direct the daylight
plate upwards towards light. If the scale is not in focus, adjust it by gently
turning the eyepiece (rubber hood) either clockwise or counterclockwise. Be
careful not to overturn the focusing mechanism.
When the refractometer scale is viewed through the eyepiece, the upper field
ofview will be seen asblue and the lower fieldwill be seen as white(Figure 2).
Confirm that the boundary line crosses the scale at “0” (Figure 3).
Ifthe boundaryline fallsaboveor belowzero, gentlyloosenthe setscrewon the
calibration ring with the supplied screwdriver. While looking through the
eyepiece, gently turn the calibration ring clockwise or counterclockwise until
the boundary line is at zero. Once this is achieved gently tighten down the set
screw with the supplied screwdriver. (NOTE: Do not over-tighten. If the set
screw is over-tightened, the boundary line may shift slightly).
When calibration is complete, gently wipe the prism using tissue paper.
Thank you for purchasing this VEE GEE Refractometer. With the user in mind, VEE GEE Refractometers are built from modern
designs and, with proper care, this instrument should provide many years of reliable performance. It’s recommended this
manual is read entirely before using the refratometer for the first time.
Introduction
Figure 1
Figure 2
Figure 3
Figure 3
66
66
6
77
77
7
VEE GEE Model SGX-1 Refractometer is equipped with an Automatic Temperature Compensation (ATC) mechanism.
Refractometers that do not feature such a mechanism must be recalibrated (zeroed) when shifts in ambient temperature
occur, or make use of a temperature correction table. Model SGX-1 automatically compensates for ambient temperature
changes (10-30°C), so recalibration is not required.
With continued use, the calibration setting on ATC refractometers can shift over time . It’s good practice to periodically check
the refractometer by conducting a measurement of distilled water. If the reading is more than one subdivision from zero,
the refractometer should be manually calibrated. Please refer to the Calibration section below.
DO NOT PERFORM CALIBRATIONS IN THE FIELD! Calibrationmusttake place
in a controlled environment of 20°C (68°F) using distilled water of the same
temperature. It’s recommended to allow the refractometer and the distilled water to
reach temperature equilibrium with the controlled environment before calibration
takes place.
Automatic Temperature Compensation

Other VEE GEE Measuring Instrument manuals

VEE GEE BX-20 User manual

VEE GEE

VEE GEE BX-20 User manual

VEE GEE BX-2 User manual

VEE GEE

VEE GEE BX-2 User manual

VEE GEE 43045 User manual

VEE GEE

VEE GEE 43045 User manual

VEE GEE 43035 User manual

VEE GEE

VEE GEE 43035 User manual

VEE GEE BX-20 User manual

VEE GEE

VEE GEE BX-20 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE NDX-1 User manual

VEE GEE

VEE GEE NDX-1 User manual

VEE GEE BX-4 User manual

VEE GEE

VEE GEE BX-4 User manual

VEE GEE C25L User manual

VEE GEE

VEE GEE C25L User manual

VEE GEE CTX-2 User manual

VEE GEE

VEE GEE CTX-2 User manual

VEE GEE BTX-20 User manual

VEE GEE

VEE GEE BTX-20 User manual

VEE GEE BX-3 User manual

VEE GEE

VEE GEE BX-3 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE BX-1 User manual

VEE GEE

VEE GEE BX-1 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE BX-10 User manual

VEE GEE

VEE GEE BX-10 User manual

VEE GEE CTX-1 User manual

VEE GEE

VEE GEE CTX-1 User manual

VEE GEE STX-3 User manual

VEE GEE

VEE GEE STX-3 User manual

VEE GEE SX-2 User manual

VEE GEE

VEE GEE SX-2 User manual

VEE GEE C10 User manual

VEE GEE

VEE GEE C10 User manual

VEE GEE BX-20 User manual

VEE GEE

VEE GEE BX-20 User manual

Popular Measuring Instrument manuals by other brands

Sierra InnovaSonic 210 instruction manual

Sierra

Sierra InnovaSonic 210 instruction manual

Simex SWE-N55L user manual

Simex

Simex SWE-N55L user manual

Black & Decker BDM100 user manual

Black & Decker

Black & Decker BDM100 user manual

Omegon LRF 600 instruction manual

Omegon

Omegon LRF 600 instruction manual

Leader LV 7800 instruction manual

Leader

Leader LV 7800 instruction manual

Gigahertz NFA 1000 operating manual

Gigahertz

Gigahertz NFA 1000 operating manual

REED 8778 instruction manual

REED

REED 8778 instruction manual

Endress+Hauser Proline t-mass I 500 technical information

Endress+Hauser

Endress+Hauser Proline t-mass I 500 technical information

ELECTROMACTIC Equipment Co., Inc. CHECK-LINE TI-45N Operating instruction guide

ELECTROMACTIC Equipment Co., Inc.

ELECTROMACTIC Equipment Co., Inc. CHECK-LINE TI-45N Operating instruction guide

Geometrics GemPen user manual

Geometrics

Geometrics GemPen user manual

Huato HE2 A Series Operation manual

Huato

Huato HE2 A Series Operation manual

Takachiho Sangyo GUIDER 6 PLUS Operation manual

Takachiho Sangyo

Takachiho Sangyo GUIDER 6 PLUS Operation manual

ANDIG 1131A user manual

ANDIG

ANDIG 1131A user manual

Honeywell Home EW130 Series Installation & user guide

Honeywell Home

Honeywell Home EW130 Series Installation & user guide

SBC Saia PCD ALD1D5FD Assembly and operating instructions

SBC

SBC Saia PCD ALD1D5FD Assembly and operating instructions

Optima Scale 909 user manual

Optima Scale

Optima Scale 909 user manual

Niigata seiki MC122-25C instruction manual

Niigata seiki

Niigata seiki MC122-25C instruction manual

Sekonic Flashmate L-308S quick guide

Sekonic

Sekonic Flashmate L-308S quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.