VEE GEE BX-3 User manual

Range: Brix 60.0-92.0%
Resolution: 0.2%
Accuracy: ±0.2%
Dimensions: 40 x 40 x 140mm (1.6 x 1.6 x 5.5”)
Weight: 230g (8.1 oz.)
Supplied With: VinylCarryingCase(1),PlasticTransferPipet(1)
Optional Oil Standard: Brix 60.0%, ¼ oz. Bottle (cat. no. 45000-OS025)
Printed in China VGMNL010320-43005
Operation Manual
Model BX-3
Brix 60-92%
Specifications
Cat. No. 43005
Temperature Correction Table
For Refractometers Calibrated At 20°C (l=589nm)
Source: ICUMSA, 1974
As an alternative to recalibration of the refractometer due to ambient temperature changes, the following temperature
correction table can be used. Ensuring that both the distilled water and the ambient temperature are both at exactly 20°C,
follow steps 2-7 under the CALIBRATION section on the preceding page. Once this is accomplished, if ambient temperature
changes, simply apply the temperature correction values listed below. For example, a reading of Brix 40.0% at 25°C is
corrected to Brix 40.4%; a reading of Brix 65.0% at 10°C is corrected to Brix 64.25%.
Warranty information and
registration form can be found at:
www.veegee.com/service_support
Refractometer Components
Calibration Ring
Mechanismusedtozeroorcalibratetherefractometer,
withouttherequirementofadditionaltools.
Rubber Hood
Houses and protects the focusable lens. Prevents
lightfrom entering through the eyepieceduringuse.
Rubber Grip
Insulatestherefractometeragainsthand
heatforaccurate results.
Non-Roll Stand
Protectsagainstdamagetotheinstrumentwhen
setdown betweenmeasurements.
Daylight Plate & Prism
The prism and sample are covered by the
daylightplate during readings.
This refractometer is an optical instrument -- it can become damaged if dropped or handled in a rough manner.
Theprism ismadeof opticalglass andissusceptible toscratches-- donot applyanyrough orabrasive materialandtake
care when cleaning the prism.
After each use, clean the prism surface and daylight plate with a soft cloth or tissue soaked in water and wipe off with
a dry cloth or tissue.
Do not hold the refractometer under a stream of water from a faucet. Do not splash it with or dip it in water.
If the surface of the prism becomes coated with an oily solution or similar, it will repel test samples and affect readings.
If this occurs, the prism should be cleaned with a weakened detergent or similar solvent.
2 3
1
2
5
4
3
Calibration
Precautions
Calibration should be conducted at the start of each day or when any shifts in
ambient temperature occur. If recalibration is impractical, refer to the directions
and temperature correction table on the following page. For standard calibration
procedures, please follow the directions below.
Open the daylight plate and apply one or two drops of a liquid standard on to
the surface of the prism [a Brix 85.0% oil standard is used for this example.
A prepared sucrose solution (weight of sucrose vs. distilled water) of a
known concentration (minimum Brix 60.0%) may also be used for
calibration purposes]. Hold the prism at an angle close to parallel with the floor
so the liquid standard will not run off of the prism.
Gently close the daylight plate over the prism. The liquid standard should spread
as a thin, even layer in between the daylight plate and the prism. By looking
through the daylight plate, ensure that the liquid standard covers the ENTIRE
surface of the prism. If there are bubbles and gaps or if the liquid standard is only
on one portion of the prism, the liquid standard must be reapplied (Figure 1).
Inaccurate calibrations will result if the prism is not covered correctly.
Lookingthrough theeyepiece, hold therefractometer anddirect the daylightplate
upwards towards light. If the scale is not in focus, adjust it by gently turning the
eyepiece (rubber hood) either clockwise or counterclockwise. Be careful not to
overturn the focusing mechanism.
When the refractometer scale is viewed through the eyepiece, the upper field of
viewwillbe seen asblueandthe lowerfield willbeseenas white(Figure 2). Confirm
thatthe boundarylinecrosses thescaleat “85”(or the valueof the liquidstandard
being used) (Figure 3).
If the boundary line falls above or below “85”, gently loosen the set screw on the
calibration ring. While looking through the eyepiece, gently turn the calibration
ring clockwise or counterclockwise until the boundary line is at “85.” Once this
is achieved gently tighten down the set screw. (NOTE: Do not over-tighten. If the
set screw is over-tightened, the boundary line may shift slightly).
When calibration is complete, gently wipe the prism using tissue paper.
Thank you for purchasing this VEE GEE Refractometer. With the user in mind, VEE GEE Refractometers are built from modern
designs and, with proper care, this instrument should provide many years of reliable performance. It’s recommended this
manual is read entirely before using the refratometer for the first time.
Introduction
1
2
5
4
3
General Use
Open the daylight plate and apply one or two drops of the sample solution to the
surface of the prism. Hold the prism at an angle close to parallel with the floor so
the sample will not run off of the prism.
Gently close the daylight plate over the prism. The sample solution should spread
as a thin, even layer in between the daylight plate and the prism. By looking
through the daylight plate, ensure that the sample solution covers the ENTIRE
surface of the prism. If there are bubbles and gaps or if the sample is only on one
portionof theprism, thesample solutionmust be reapplied(Figure 1). Inaccurate
readings will result if the prism is not covered correctly.
Lookingthrough theeyepiece, hold therefractometer anddirect the daylightplate
upwards towards light. If the scale is not in focus, adjust it by gently turning the
eyepiece (rubber hood) either clockwise or counterclockwise. Be careful not to
overturn the focusing mechanism.
When the refractometer scale is viewed through the eyepiece, the upper field of
view will be seen as blue and the lower field will be seen as white (Figure 4). The
reading is taken at the point where the boundary line of the blue and white fields
crosses the scale (Figure 5). The value is the Brix% reading of the sample.
When each measurement is complete, the sample must be cleaned from the
prism using tissue paper and water.
Calibration Ring Set Screw
Securesthecalibrationringinplace to protect
fromanyshiftswhichcould occur during use.
6
7
Figure 1
Figure 2
Figure 3
Figure 4
Figure 3
Figure 5
Figure 3

Other VEE GEE Measuring Instrument manuals

VEE GEE SX-2 User manual

VEE GEE

VEE GEE SX-2 User manual

VEE GEE SGX-1 User manual

VEE GEE

VEE GEE SGX-1 User manual

VEE GEE C10 User manual

VEE GEE

VEE GEE C10 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE BX-10 User manual

VEE GEE

VEE GEE BX-10 User manual

VEE GEE BX-20 User manual

VEE GEE

VEE GEE BX-20 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE STX-3 User manual

VEE GEE

VEE GEE STX-3 User manual

VEE GEE BX-2 User manual

VEE GEE

VEE GEE BX-2 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE CTX-2 User manual

VEE GEE

VEE GEE CTX-2 User manual

VEE GEE BX-20 User manual

VEE GEE

VEE GEE BX-20 User manual

VEE GEE CTX-1 User manual

VEE GEE

VEE GEE CTX-1 User manual

VEE GEE 43035 User manual

VEE GEE

VEE GEE 43035 User manual

VEE GEE BX-4 User manual

VEE GEE

VEE GEE BX-4 User manual

VEE GEE BX-1 User manual

VEE GEE

VEE GEE BX-1 User manual

VEE GEE BTX-20 User manual

VEE GEE

VEE GEE BTX-20 User manual

VEE GEE C25L User manual

VEE GEE

VEE GEE C25L User manual

VEE GEE NDX-1 User manual

VEE GEE

VEE GEE NDX-1 User manual

VEE GEE BTX-1 User manual

VEE GEE

VEE GEE BTX-1 User manual

VEE GEE 43045 User manual

VEE GEE

VEE GEE 43045 User manual

VEE GEE BX-20 User manual

VEE GEE

VEE GEE BX-20 User manual

Popular Measuring Instrument manuals by other brands

Metrix MTX I 050-PC user manual

Metrix

Metrix MTX I 050-PC user manual

Metrix PX 110 user manual

Metrix

Metrix PX 110 user manual

Unit UT-8802E user manual

Unit

Unit UT-8802E user manual

Flo-tech Flo-Check USB Installation & programming instructions

Flo-tech

Flo-tech Flo-Check USB Installation & programming instructions

AU Tool X60 user manual

AU Tool

AU Tool X60 user manual

Lake Shore 425 user manual

Lake Shore

Lake Shore 425 user manual

Brain Bee OPA-100 Service manual

Brain Bee

Brain Bee OPA-100 Service manual

TAS TA120 Series instruction manual

TAS

TAS TA120 Series instruction manual

Check-line TI-25M operating instructions

Check-line

Check-line TI-25M operating instructions

AU Tool LM120 Plus user manual

AU Tool

AU Tool LM120 Plus user manual

Avonic AV-REC200 user manual

Avonic

Avonic AV-REC200 user manual

Digi-Sense 20250-14 user manual

Digi-Sense

Digi-Sense 20250-14 user manual

Tinker & Rasor PRM Product instructions

Tinker & Rasor

Tinker & Rasor PRM Product instructions

Promax SATHUNTER+ user manual

Promax

Promax SATHUNTER+ user manual

AutoTest AutoLight PLUS MAGNETIC user manual

AutoTest

AutoTest AutoLight PLUS MAGNETIC user manual

J-TECH Hobby-Fab  OX instructions

J-TECH

J-TECH Hobby-Fab OX instructions

etrailer E-Volt product manual

etrailer

etrailer E-Volt product manual

Pro's Kit MT-4616 user manual

Pro's Kit

Pro's Kit MT-4616 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.