Ventair Brook 4 Installation guide

HIGH AIRFLOW
3 IN 1 BATHROOM FAN, HEAT & LIGHT
IMPORTANT INSTALLATION INSTRUCTION AND WARRANTY INSTRUCTIONS
Thank you and congratulations on your purchase of the
Ventair 3 in 1 Bathroom Fan, Heat & Light. Please read these
instructions carefully before installing and using the product.
Keep the instructions handy for future reference.
Electrical wiring must only be done by a licensed electrician
and a “Certificate of Compliance” must be issued upon
completion of the installation.
LOCATION
The unit must be located and installed in accordance with
AS/NZS 3000 and local building codes and regulations
concerning the discharge of air have to be fulfilled.
The unit can be installed in any room that requires direct
radiant heating and circulated air flow such as bathrooms,
ensuites, laundries etc. The unit can be installed in flat ceilings
with a minimum height of 2 meters. At least 250mm height
clearance in the ceiling cavity is required to ensure sufficient
ventilation for moisture to disperse. The unit must also be
installed at least 400mm away from the walls.
Ensure adequate inlets exist through windows, vents or under
the door for air flow.
POWER
AC 220-240V, 50/60Hz electrical supply is required. The unit
can be connected to a lighting or power circuit if loading
permits. All electrical work must be carried out in accordance
with AS/NZS 3000 or latest edition thereof.
MOUNTING
1.The unit may be mounted either between
joists using the inbuilt clip fasteners or
against a joist using a screw through the
flange plate. Use this card in its open state
as a template. Place in the required
location and mark out the hole cutting
size. Hole size is 375mm x 375mm with a
160mm x 15mm bulge.
2.Before commencing cutting ensure that
the area behind the intended location is
clear of all cables, pipes and joists. Once
clear, cut out the section along the
previously marked lines.
3.Remove 4 heat lamps from the unit, then
remove the plug of the led downlight
inside the housing. Unfasten the fascia
retaining spring clips inside the housing,
and remove the fascia. Connect the
ducting (if required) to the outer grill of
the unit. Insert the unit into the square
hole being sure to pull the side springs
inward so that the body can pass through
the hole without damaging the plaster.
Ensure that the unit is held securely in
place by the clips. If required, additional
screws can be used to aid holding the unit
in the ceiling. Screw holes are provided in
the flange for this purpose.
4.Connect the led downlight plugs firstly.
Hold the fascia against the body of the
heater and the ceiling and attach the
securing spring clips to hold the fascia in
place.
5.Now screw in the four large heat lamps
into the lamp holder through the holes
provided in the fascia. The globes should
be screwed up firmly to ensure a good
electrical contact but don’t over tighten.
1
5
3
2
4
ELECTRICAL WIRING
The bathroom heater unit must be wired in accordance with
Australian Wiring Rules AS/NZS 3000.
Note: This unit is fitted with a thermostat switch which will
operate to automatically switch the fan on in the event that the
internal temperature of the unit exceeds 60℃.
CARE AND MAINTENANCE
1.During the installation of this bathroom heater, please make sure
that the person in the bathtub or in the shower area cannot reach the
electrical switches and other electrical controllers.
2.This bathroom heater mustn’t be installed below the electrical outlet.
3.This bathroom heater mustn’t be installed nearby the curtains
and other combustible materials.
4.This bathroom heater must under no circumstances be covered
with insulation material or similar material.
5.Joists, beams and rafters shall not be cut or notched to install this
bathroom heater.
6.Lamps must be cool before cleaning. To clean bulbs and surrounds,
wipe with a cloth dampened with detergent or liquid glass cleaner.
7.To prolong the life of yours 3-in-1 bathroom heater fan light, avoid
using heat lamp alone for longer than 10 minutes. Using the fan
function along with the heat lamp to allow cooling of your 3-in-1
bathroom heater light.
8.This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not
play with the appliance.
REPLACEMENT LAMPS
HEAT LAMPS: The heat lamps must only be replaced with 275
watt (maximum) lamps.
CENTRE LAMP: 10 watt (maximum) led downlight,4000K,700LM,
size:108mmx68mm(Available from place of purchase of
Ventair Pty Ltd.)
This unit must be installed by a qualified licensed electrician.
Every Ventair 3 in 1 is thoroughly inspected and tested before being released for sale. In
addition to any warranties or conditions implied by applicable Statue or Regulation,
Ventair Design warrants all of its bathroom heaters against defective workmanship and
faulty materials for 3 years from the original date of purchase. Ventair Design undertakes,
at its option, to repair or replace, free of charge, each product or part thereof subject to
the below warranty conditions:
1.The fan or relevant part has not been modified, subjected to misuse, neglect, or been involved
in an accident.
2.The repairs are not required as a result of normal wear and tear.
3.The product was installed by a licensed electrical contractor in accordance with this instruction
manual.
4.No solid state speed control device has been used with the appliance.
5.A copy of the original receipt of purchase is presented.
6.Globes supplied are not covered by this warranty.
Ventair can not be held responsible for any repair other than those carried out by it or one
of its Authorised Service Agents. Please keep this warranty card in a safe place. This card
must be produced in the event of service being required.
MODEL (SKU) NUMBER:
DATE OF PURCHASE:
RETAILER:
RECEIPT NUMBER:
INSTALLED BY:
LICENSE#: PH:
DESCRIPTION OF FAULT:
BATHROOM HEATER WARRANTY CARD
TERMINAL BLOCK
220-240V a.c 50/60Hz
LIGHT: 10W led downlight
HEATER: 4 x 275W
FAN: 40W
375x375mm VHF4W
Motor Power
Industry Standard

This manual suits for next models

1

Other Ventair Fan manuals

Ventair GYRO 200 Installation guide

Ventair

Ventair GYRO 200 Installation guide

Ventair Z564EXTSS User manual

Ventair

Ventair Z564EXTSS User manual

Ventair SPINIKA Series User manual

Ventair

Ventair SPINIKA Series User manual

Ventair SPYDA SPY903NWH User manual

Ventair

Ventair SPYDA SPY903NWH User manual

Ventair Orbital 45 User manual

Ventair

Ventair Orbital 45 User manual

Ventair MALIBU Series User manual

Ventair

Ventair MALIBU Series User manual

Ventair SPYDAEC SPYEC1253WH User manual

Ventair

Ventair SPYDAEC SPYEC1253WH User manual

Ventair HARMONY II Series User manual

Ventair

Ventair HARMONY II Series User manual

Ventair GYRO 250 Installation guide

Ventair

Ventair GYRO 250 Installation guide

Ventair FAN0530 User manual

Ventair

Ventair FAN0530 User manual

Ventair ROYALE DC Series User manual

Ventair

Ventair ROYALE DC Series User manual

Ventair STANZA STA1203WH-LR User manual

Ventair

Ventair STANZA STA1203WH-LR User manual

Ventair DC 3 Series User manual

Ventair

Ventair DC 3 Series User manual

Ventair Stanza STA1203WH User manual

Ventair

Ventair Stanza STA1203WH User manual

Ventair WAL75-DC User manual

Ventair

Ventair WAL75-DC User manual

Ventair MALIBU MAL1404WH User manual

Ventair

Ventair MALIBU MAL1404WH User manual

Ventair VWF150AS Assembly instructions

Ventair

Ventair VWF150AS Assembly instructions

Ventair PRO-V PVPX200WH User manual

Ventair

Ventair PRO-V PVPX200WH User manual

Ventair Mixflow Assembly instructions

Ventair

Ventair Mixflow Assembly instructions

Ventair MANROSE SIERRA MR2DXWH User manual

Ventair

Ventair MANROSE SIERRA MR2DXWH User manual

Ventair GLA1203WH User manual

Ventair

Ventair GLA1203WH User manual

Ventair WAL45-DC User manual

Ventair

Ventair WAL45-DC User manual

Ventair PRO-V Slimline VSLF100 Assembly instructions

Ventair

Ventair PRO-V Slimline VSLF100 Assembly instructions

Popular Fan manuals by other brands

Vents VKP EC SERIES user manual

Vents

Vents VKP EC SERIES user manual

Sulion DUPLO manual

Sulion

Sulion DUPLO manual

Emerson PRO CF712AB01 owner's manual

Emerson

Emerson PRO CF712AB01 owner's manual

Rubine RCF-VETTA101-5B user manual

Rubine

Rubine RCF-VETTA101-5B user manual

Vortice EVOLUTION LIGHT KIT ES Instruction booklet

Vortice

Vortice EVOLUTION LIGHT KIT ES Instruction booklet

Munters TU600 Manual for use and maintenance

Munters

Munters TU600 Manual for use and maintenance

Envirovent PIV Installation and user guide

Envirovent

Envirovent PIV Installation and user guide

Teral CTFII instruction manual

Teral

Teral CTFII instruction manual

Abicor Binzel xFume Advanced operating instructions

Abicor Binzel

Abicor Binzel xFume Advanced operating instructions

Casablanca M8515-01 installation manual

Casablanca

Casablanca M8515-01 installation manual

Sulion 2183046 manual

Sulion

Sulion 2183046 manual

Schwank MonsterFan Series Use instruction

Schwank

Schwank MonsterFan Series Use instruction

KDK M40R operating instructions

KDK

KDK M40R operating instructions

NuAire Genie/tops 230 volt Installation and Maintenance

NuAire

NuAire Genie/tops 230 volt Installation and Maintenance

Alpha Fan AX20-5B/56 instruction manual

Alpha Fan

Alpha Fan AX20-5B/56 instruction manual

Melissa 671-106 manual

Melissa

Melissa 671-106 manual

CLEANTEC LANG Instructions of use

CLEANTEC

CLEANTEC LANG Instructions of use

Aria QBVS110L owner's manual

Aria

Aria QBVS110L owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.